Search NASAβŒ• Search

Engineering topics

Mueller, P. E.

Publications and source records attributed to Mueller, P. E..

31 records Β· Page 2

A low mass optical grid for the PROSPECT reactor antineutrino detector

PROSPECT, the Precision Reactor Oscillation and SPECTrum experiment, is a shortbaseline reactor antineutrino experiment designed to provide precision measurements of the 235U product $\overline{v}$ e spectrum, utilizing an optically segmented 4-ton liquid scintillator detector. PROSPECT’s segmentation system, the optical grid, plays a central role in reconstructing the position and energy of $\overline{v}$ e interactions in the detector. This paper is the technical reference for this PROSPECT subsystem, describing its design, fabrication, quality assurance, transportation, and assembly in detail. In addition, the dimensional, optical and mechanical characterizations of optical grid components and the assembled PROSPECT target are also presented. The technical information and characterizations detailed here will inform geometry-related inputs for PROSPECT physics analysis and can guide a variety of future particle detection development efforts, such as those using optically reflecting materials or filament-based 3D printing.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lithium-loaded liquid scintillator production for the PROSPECT experiment

This work reports here the production and characterization of lithium-loaded liquid scintillator (LiLS) for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT) . Fifty-nine 90 liter batches of LiLS ( 6 Li mass fraction 0.082%Β±0.001%) were produced and samples from all batches were characterized by measuring their optical absorbance relative to air, light yield relative to a pure liquid scintillator reference, and pulse shape discrimination capability. Fifty-seven batches passed the quality assurance criteria and were used for the PROSPECT experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND β†—

The PROSPECT reactor antineutrino experiment

The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, is designed to make both a precise measurement of the antineutrino spectrum from a highly-enriched uranium reactor and to probe eV-scale sterile neutrinos by searching for neutrino oscillations over meter-long baselines. PROSPECT utilizes a segmented 6 Li-doped liquid scintillator detector for both efficient detection of reactor antineutrinos through the inverse beta decay reaction and excellent background discrimination. PROSPECT is a movable 4-ton antineutrino detector covering distances of 7 m to 13 m from the High Flux Isotope Reactor core. It will probe the best-fit point of the vΒ― e disappearance experiments at 4 Οƒ in 1 year and the favored regions of the sterile neutrino parameter space at more than 3Οƒ in 3 years. PROSPECT will test the origin of spectral deviations observed in recent ΞΈ 13 experiments, search for sterile neutrinos, and address the hypothesis of sterile neutrinos as an explanation of the reactor anomaly. This study describes the design, construction, and commissioning of PROSPECT and reports first data characterizing the performance of the PROSPECT antineutrino detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Observation of 𝑃-odd 𝛾 Asymmetry in Polarized Neutron Capture on Hydrogen

Here, we report the first observation of the parity-violating gamma-ray asymmetry 𝐴$^{𝑛⁒𝑝}_{𝛾}$ in neutron-proton capture using polarized cold neutrons incident on a liquid parahydrogen target at the Spallation Neutron Source at Oak Ridge National Laboratory. 𝐴$^{𝑛⁒𝑝}_{𝛾}$ isolates the Δ⁒𝐼 =1, 3 𝑆 1 β†’ 3 𝑃 1 component of the weak nucleon-nucleon interaction, which is dominated by pion exchange and can be directly related to a single coupling constant in either the DDH meson exchange model or pionless effective field theory. We measured 𝐴$^{𝑛⁒𝑝}_{𝛾}$=[βˆ’3.0Β±1.4⁒(stat)Β±0.2⁒(syst)]Γ—10 βˆ’8 , which implies a DDH weak πœ‹β’π‘β’π‘ coupling of β„Ž$^1_πœ‹$=[2.6Β±1.2⁒(stat)Β±0.2⁒(syst)]Γ—10 βˆ’7 and a pionless EFT constant of 𝐢 3 𝑆 1 β†’ 3 𝑃 1 /𝐢 0 =[βˆ’7.4Β±3.5⁒(stat)Β±0.5⁒(syst)]Γ—10 βˆ’11 MeV βˆ’1 . We describe the experiment, data analysis, systematic uncertainties, and implications of the result.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Using Nab to determine correlations in unpolarized neutron decay

The Nab experiment will measure the ratio of the weak axial-vector and vector coupling constants Ξ» = gA/gV with precision δλ/Ξ» ~3 Γ— 10 -4 and search for a Fierz term b F at a level Ξ”b F < 10 -3 . The Nab detection system uses thick, large area, segmented silicon detectors to very precisely determine the decay proton’s time of flight and the decay electron’s energy in coincidence and reconstruct the correlation between the antineutrino and electron momenta. Excellent understanding of systematic effects affecting timing and energy reconstruction using this detection system are required. Here, to explore these effects, a series of ex situ studies have been undertaken, including a search for a Fierz term at a less sensitive level of Ξ”b F < 10 -2 in the beta decay of 45 Ca using the UCNA spectrometer.

Beta spectrum↗

Performance of a segmented 6 Li-loaded liquid scintillator detector for the PROSPECT experiment

This study describes the design and performance of a 50 liter, two-segment 6 Li-loaded liquid scintillator detector that was designed and operated as prototype for the PROSPECT (Precision Reactor Oscillation and Spectrum) Experiment. The two-segment detector was constructed according to the design specifications of the experiment. It features low-mass optical separators, an integrated source and optical calibration system, and materials that are compatible with the 6 Li-doped scintillator developed by PROSPECT. We demonstrate a high light collection of 850Β±20 PE/MeV, an energy resolution of Οƒ = 4.0Β±0.2% at 1 MeV, and efficient pulse-shape discrimination of low dE/dx (electronic recoil) and high dE/dx (nuclear recoil) energy depositions. An effective scintillation attenuation length of 85Β±3 cm is measured in each segment. The 0.1% by mass concentration of 6 Li in the scintillator results in a measured neutron capture time of Ο„ = 42.8Β±0.2 ΞΌs. The long-term stability of the scintillator is also discussed. Finally, the detector response meets the criteria necessary for achieving the PROSPECT physics goals and demonstrates features that may find application in fast neutron detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND β†—

Measurement of the absolute neutron beam polarization from a supermirror polarizer and the absolute efficiency of a neutron spin rotator for the NPDGamma experiment using a polarized 3 He neutron spin-filter

Accurately measuring the neutron beam polarization of a high flux, large area neutron beam is necessary for many neutron physics experiments. The Fundamental Neutron Physics Beamline (FnPB) at the Spallation Neutron Source (SNS) is a pulsed neutron beam that was polarized with a supermirror polarizer for the NPDGamma experiment. The polarized neutron beam had a flux of ~10 9 neutrons per second per cm 2 and a cross sectional area of 10 x 12 cm 2 . The polarization of this neutron beam and the efficiency of a RF neutron spin rotator installed downstream on this beam were measured by neutron transmission through a polarized 3 He neutron spin-filter. The pulsed nature of the SNS enabled us to employ an absolute measurement technique for both quantities which does not depend on accurate knowledge of the phase space of the neutron beam or the 3 He polarization in the spin filter and is therefore of interest for any experiments on slow neutron beams from pulsed neutron sources which require knowledge of the absolute value of the neutron polarization. The polarization and spin-reversal efficiency measured were done for the NPDGamma experiment, which measures the parity violating Ξ³-ray angular distribution asymmetry with respect to the neutron spin direction in the capture of polarized neutrons on protons. Finally, the experimental technique, results, systematic effects, and applications to neutron capture targets are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND β†—

The PROSPECT physics program

The precision reactor oscillation and spectrum experiment, PROSPECT, is designed to make a precise measurement of the antineutrino spectrum from a highly-enriched uranium reactor and probe eV-scale sterile neutrinos by searching for neutrino oscillations over a distance of several meters. The subject of this paper, PROSPECT, is conceived as a 2-phase experiment utilizing segmented 6 Li-doped liquid scintillator detectors for both efficient detection of reactor antineutrinos through the inverse beta decay reaction and excellent background discrimination. PROSPECT Phase I consists of a movable 3 ton antineutrino detector at distances of 7–12 m from the reactor core. It will probe the best-fit point of the Ξ½ e disappearance experiments at 4Οƒ in 1 year and the favored region of the sterile neutrino parameter space at > 3Οƒ in 3 years. With a second antineutrino detector at 15–19 m from the reactor, Phase II of PROSPECT can probe the entire allowed parameter space below 10 eV 2 at 5Οƒ in 3 additional years. Finally, the measurement of the reactor antineutrino spectrum and the search for short-baseline oscillations with PROSPECT will test the origin of the spectral deviations observed in recent ΞΈ 13 experiments, search for sterile neutrinos, and conclusively address the hypothesis of sterile neutrinos as an explanation of the reactor anomaly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Background radiation measurements at high power research reactors

Research reactors host a wide range of activities that make use of the intense neutron fluxes generated at these facilities. Recent interest in performing measurements with relatively low event rates, e.g. reactor antineutrino detection, at these facilities necessitates a detailed understanding of background radiation fields. Both reactor-correlated and naturally occurring background sources are potentially important, even at levels well below those of importance for typical activities. Here we describe a comprehensive series of background assessments at three high-power research reactors, including Ξ³-ray, neutron, and muon measurements. For each facility we describe the characteristics and identify the sources of the background fields encountered. Furthermore, the general understanding gained of background production mechanisms and their relationship to facility features will prove valuable for the planning of any sensitive measurement conducted therein.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measurement of the scattering cross section of slow neutrons on liquid parahydrogen from neutron transmission

Liquid hydrogen is a dense Bose fluid whose equilibrium properties are both calculable from first principles using various theoretical approaches and of interest for the understanding of a wide range of questions in many-body physics. Unfortunately, the pair correlation function g(r) inferred from neutron scattering measurements of the differential cross section dσ/dΩ from different measurements reported in the literature are inconsistent. We have measured the energy dependence of the total cross section and the scattering cross section for slow neutrons with energies between 0.43 and 16.1 meV on liquid hydrogen at 15.6 K (which is dominated by the parahydrogen component) using neutron transmission measurements on the hydrogen target of the NPDGamma collaboration at the Spallation Neutron Source at Oak Ridge National Laboratory. The relationship between the neutron transmission measurement we perform and the total cross section is unambiguous, and the energy range accesses length scales where the pair correlation function is rapidly varying. At 1 meV our measurement is a factor of 3 below the data from previous work. We present evidence that these previous measurements of the hydrogen cross section, which assumed that the equilibrium value for the ratio of orthohydrogen and parahydrogen has been reached in the target liquid, were in fact contaminated with an extra nonequilibrium component of orthohydrogen. Liquid parahydrogen is also a widely used neutron moderator medium, and an accurate knowledge of its slow neutron cross section is essential for the design and optimization of intense slow neutron sources. Furthermore, we describe our measurements and compare them with previous work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND β†—