Search NASA⌕ Search

Engineering topics

Mufson, S.

Publications and source records attributed to Mufson, S..

Differences in the response of two light guide technologies and two readout technologies after an exchange of liquid argon in the dewar

In this investigation the response to the scintillation light generated by through-going cosmic muons in liquid argon (LAr) was measured by two light guide technologies and two readout technologies after five weeks of running in the TallBo dewar at Fermilab. The response was remeasured after the dewar was drained of LAr, refilled, and then run again for an additional four weeks. After the dewar was refilled, there was clear evidence that the scintillation signal had dropped significantly. The two light guide technologies were developed at Indiana University and MIT/Fermilab. The two readout technologies were boards that passively or actively ganged 12 Hamamatsu MPPCs. Two possible explanations were identified for the degraded signal: the response of the two light guide technologies degraded due to damage caused by thermal cycling, and/or unknown differences in the trace residual Xe contamination in the fills of LAr led to the observed drop in scintillation light. Neither absorption nor quenching by N 2 , O 2 , and H 2 O contamination can account for the degradation. Neither the individual Hamamatsu MPPCs nor the passive/active ganging boards appear to have been affected by the thermal cycling. The path length distributions of the cosmics traversing the dewar appear quite similar in both event samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A measurement of absolute efficiency of the ARAPUCA photon detector in liquid argon

In the Fall of 2017, two photon detector designs for the Deep Underground Neutrino Experiment (DUNE) Far Detector were installed and tested in the TallBo liquid argon (LAr) cryostat at the Proton Assembly (PAB) facility, Fermilab. The designs include two light bars developed at Indiana University and a photon detector based on the ARAPUCA light trap engineered by Colorado State University and Fermilab. The performance of these devices is determined by analyzing 8 weeks of cosmic ray data. The current paper focuses solely on the ARAPUCA device as the performance of the light bars will be reported separately. The article briefly describes the ARAPUCA concept, the TallBo setup, and focuses on data analysis and results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and performance of a 35-ton liquid argon time projection chamber as a prototype for future very large detectors

Liquid argon time projection chamber technology is an attractive choice for large neutrino detectors, as it provides a high-resolution active target and it is expected to be scalable to very large masses. Consequently, it has been chosen as the technology for the first module of the DUNE far detector. However, the fiducial mass required for “far detectors” of the next generation of neutrino oscillation experiments far exceeds what has been demonstrated so far. Scaling to this larger mass, as well as the requirement for underground construction places a number of additional constraints on the design. A prototype 35-ton cryostat was built at Fermi National Acccelerator Laboratory to test the functionality of the components foreseen to be used in a very large far detector. The Phase I run, completed in early 2014, demonstrated that liquid argon could be maintained at sufficient purity in a membrane cryostat. A time projection chamber was installed for the Phase II run, which collected data in February and March of 2016. The Phase II run was a test of the modular anode plane assemblies with wrapped wires, cold readout electronics, and integrated photon detection systems. While the details of the design do not match exactly those chosen for the DUNE far detector, the 35-ton TPC prototype is a demonstration of the functionality of the basic components. Measurements are performed using the Phase II data to extract signal and noise characteristics and to align the detector components. A measurement of the electron lifetime is presented, and a novel technique for measuring a track's position based on pulse properties is described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlated ground based observations in support of the HEAO-1 X-ray observatory

Using X-ray and optical photometry of UBVRI fluxes, energetic compact extragalactic sources were studied, such as BL Lacerta (Lac) and BL Lac objects-Markarian (Mrk) 421, Mrk 501, and B2 1308+32. BL Lac and BL Lac objects were found to have predominantly nonthermal spectrums. Photometric and spectroscopic properties of X Persei, an unusual Be star associated with an intrinsically weak X-ray source, were also studied. Both its X-ray and optical emission show complex variability on many different time scales.

Mufson, S.↗

Coordinated photometric and spectroscopic observations of strong extragalactic 90 GHz sources

Nearly simultaneous radio and infrared-optical observations were obtained for several extragalactic radio sources which are strong at 90 GHz. The spectral-flux distributions are generally peaked or flat over the radio portion of the spectrum with a steeper, power-law behavior at infrared-optical frequencies. For all sources, the radio and infrared-optical portions of the spectral-flux distributions can be smoothly joined by physically sensible interpolations over the spectral gap, although spectral breaks are required. For many of the sources, this is consistent with a common (synchrotron) origin of the radio, millimeter, and infrared-optical radiation. However, proof, in terms of correlated temporal variations and polarization properties, is still generally lacking.

Odell, S. L.↗