Search NASA⌕ Search

Engineering topics

Mukherjee, A.

Publications and source records attributed to Mukherjee, A..

Workshop on a future muon program at FNAL

The Snowmass report on rare processes and precision measurements recommended Mu2e-II and a next generation muon facility at Fermilab (Advanced Muon Facility) as priorities for the frontier. The Workshop on a future muon program at FNAL was held in March 2023 to discuss design studies for Mu2e-II, organizing efforts for the next generation muon facility, and identify synergies with other efforts (e.g., muon collider). Topics included high-power targetry, status of R&D for Mu2e-II, development of compressor rings, FFA and concepts for muon experiments (conversion, decays, muonium and other opportunities) at AMF. This document summarizes the workshop discussions with a focus on future R&D tasks needed to realize these concepts.

43 PARTICLE ACCELERATORS↗

High spatial resolution direct conversion amorphous selenium X-ray detectors with monolithically integrated CMOS readout

Recent progress in the field of micron-scale spatial resolution direct conversion X-ray detectors for high-energy synchrotron light sources serve applications ranging from nondestructive and noninvasive microscopy techniques which provide insight into the structure and morphology of crystals, to medical diagnostic measurement devices. Amorphous selenium ( a -Se) as a wide-bandgap thermally evaporated photoconductor exhibits ultra-low thermal generation rates for dark carriers and has been extensively used in X-ray medical imaging. Being an amorphous material, it can further be deposited over large areas at room temperatures and at substantially lower costs as compared to crystalline semiconductors. Here, to address the demands for a high-energy and high spatial resolution X-ray detector for synchrotron light source applications, we have thermally evaporated a -Se on a Mixed-Mode Pixel Array Detector (MM-PAD) Application Specific Integrated Circuit (ASIC). The ASIC format consists of 128 × 128 square pixels each 150 μm on a side. A 200 μm a -Se layer was directly deposited on the ASIC followed by a metal top electrode. The completed detector assembly was tested with 45 kV Ag and 23 kV Cu X-ray tube sources. The detector fabrication, performances, Modulation Transfer Function (MTF) measurements, and simulations are reported.

36 MATERIALS SCIENCE↗

Linear dichroism infrared resonance in overdoped, underdoped, and optimally doped cuprate superconductors

By measuring the polarization changes in terahertz, infrared, and visible radiation over an extended energy range (3–2330 meV), we observe symmetry breaking in cuprate high-temperature superconductors over wide energy, doping, and temperature ranges. We measure the polarization rotation (Re[$θ_F$]) and ellipticity (Im[$θ_F$]) of transmitted radiation through thin films as the sample is rotated. We observe a twofold rotational symmetry in $θ_F$, which is associated with linear dichroism (LD) and occurs when electromagnetic radiation polarized along one direction is absorbed more strongly than radiation polarized in the perpendicular direction. Such polarization anisotropies can be generally associated with symmetry breakings. We measure the amplitude of the LD signal and study its temperature, energy, and doping dependence. The LD signal shows a resonant behavior with a peak in the few hundred meV range, which is coincident with the midinfrared optical feature that has been associated with the formation of the pseudogap state. In this work, the strongest LD signal is found in underdoped films, although it is also observed in optimally and overdoped samples. The LD signal is consistent with an electronic nematic order which is decoupled from the crystallographic axes as well as novel magnetoelectric effects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Transverse spin effects in hard semi-inclusive collisions

The nucleons (protons and neutrons) are by far the most abundant form of matter in our visible Universe; they are composite particles made of quarks and gluons, the fundamental quanta of Quantum Chromo Dynamics (QCD). The usual interpretation of the nucleon dynamics in high energy interactions is often limited to a simple one-dimensional picture of a fast moving nucleon as a collection of co-linearly moving quarks and gluons (partons), interacting accordingly to perturbative QCD rules. However, massive experimental evidence shows that, in particular when transverse spin dependent observables are involved, such a simple picture is not adequate. The intrinsic transverse motion of partons has to be taken into account; this opens the way to a new, truly 3-dimensional (3D) study of the nucleon structure. A review of the main experimental data, their interpretation and understanding in terms of new transverse momentum dependent partonic distributions, and the progress in building a 3D imaging of the nucleon is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Giant magneto-optical Kerr enhancement from films on SiC due to the optical properties of the substrate

We report a giant enhancement of the midinfrared magneto-optical complex Kerr angle (polarization change of reflected light) in a variety of materials grown on SiC. In epitaxially grown multilayer graphene, the Kerr angle is enhanced by a factor of 68, which is in good agreement with Kerr signal modeling. Strong Kerr enhancement is also observed in Fe films grown on SiC and Al-doped bulk SiC. Our experiments and modeling indicate that the enhancement occurs at the high-energy edge of the SiC reststrahlen band where the real component of the complex refractive index n˜ passes through unity. Furthermore, since the signal is greatly enhanced when n˜ = 1, the enhancement is predicted to exist over the entire visible and IR spectrum for a free-standing film. We also predict similar giant enhancement in both Faraday (transmission) and Kerr rotation for thin films on a metamaterial substrate with refractive index n˜ = –1. Furthermore, this paper demonstrates that the substrate used in magneto-optical Kerr effect (MOKE) measurements must be carefully chosen when investigating magneto-optical materials with weak MOKE signals or when designing MOKE-based optoelectronic devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improved frame-based estimation of head motion in PET brain imaging

Purpose: Head motion during PET brain imaging can cause significant degradation of image quality. Several authors have proposed ways to compensate for PET brain motion to restore image quality and improve quantitation. Head restraints can reduce movement but are unreliable; thus the need for alternative strategies such as data-driven motion estimation or external motion tracking. Herein, the authors present a data-driven motion estimation method using a preprocessing technique that allows the usage of very short duration frames, thus reducing the intraframe motion problem commonly observed in the multiple frame acquisition method. Methods: The list mode data for PET acquisition is uniformly divided into 5-s frames and images are reconstructed without attenuation correction. Interframe motion is estimated using a 3D multiresolution registration algorithm and subsequently compensated for. For this study, the authors used 8 PET brain studies that used F-18 FDG as the tracer and contained minor or no initial motion. After reconstruction and prior to motion estimation, known motion was introduced to each frame to simulate head motion during a PET acquisition. To investigate the trade-off in motion estimation and compensation with respect to frames of different length, the authors summed 5-s frames accordingly to produce 10 and 60 s frames. Summed images generated from the motion-compensated reconstructed frames were then compared to the original PET image reconstruction without motion compensation. Results: The authors found that our method is able to compensate for both gradual and step-like motions using frame times as short as 5 s with a spatial accuracy of 0.2 mm on average. Complex volunteer motion involving all six degrees of freedom was estimated with lower accuracy (0.3 mm on average) than the other types investigated. Preprocessing of 5-s images was necessary for successful image registration. Since their method utilizes nonattenuation corrected frames, it is not susceptible to motion introduced between CT and PET acquisitions. Conclusions: The authors have shown that they can estimate motion for frames with time intervals as short as 5 s using nonattenuation corrected reconstructed FDG PET brain images. Intraframe motion in 60-s frames causes degradation of accuracy to about 2 mm based on the motion type.

60 APPLIED LIFE SCIENCES↗

Mu2e Conceptual Design Report

Mu2e at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the LHC. We describe herein the conceptual design of the proposed Mu2e experiment. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-1 approval, which was granted July 11, 2012.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast Beam Tuning for Accelerator Driven Systems

The biggest challenge for Accelerator Driven Systems (ADS) is the stringent availability requirement of >99% compared to ~80% achieved by a typical accelerators. In addition to overall availability, due to thermal stress problems, ADS is also sensitive to the length of each downtime. A significant source of downtime is re-adjustment tuning of the system to account for drift in component behavior, or substitution of a backup device for one that failed. Tuning at present is done by hand, i.e. with human observation, interpretation, and decision, a process which takes hours; whereas ADS requires recovery in minutes. In this research, we apply intelligent controls in a (simulated) proton linac to automate fine-tuning. Beam monitor data is fed into a controller which adjusts magnet currents and RF power to minimize beam loss. We consider fluctuations in ion source characteristics; drift in magnet behavior (mechanical motion, or change in calibration); and failure of an accelerating cavity.

43 PARTICLE ACCELERATORS↗

Reliability Modeling Method for Proton Accelerator

Reliability Analysis is an essential part of designing any complex system in order to predict performance and understand availability. However modeling complex systems has been a challenging task due to the large number of components and inter -dependencies. The options have been custom written simulation packages, requiring large investment of programming and debugging time; or standard commercial software running for many days. In our research we developed a hierarchical method to represent t he reliability model of Project X, * a proposed linear accelerator at Fermi National Accelerator Laboratory. The system is first divided into subsystems small enough to readily simulate. Each subsystem is then separately simulated and parameterized so th ey can be represented as simple blocks in the top level system diagram. This allows standard, commercial software to model systems with many tens of thousands of components without requiring many days of computer time. Simulation were run and compared wit h data gathered from existing accelerators.

43 PARTICLE ACCELERATORS↗

Model independent analysis of gluonic pole matrix elements and universality of transverse-momentum-dependent fragmentation functions

Gluonic pole matrix elements explain the appearance of single spin asymmetries (SSA) in high-energy scattering processes. They involve a combination of operators which are odd under time reversal (T-odd). Such matrix elements appear in principle both for parton distribution functions and parton fragmentation functions. We show that for parton fragmentation functions these gluonic pole matrix elements vanish as a consequence of the analytic structure of scattering amplitudes in Quantum Chromodynamics. Furthermore, this result is important in the study of the universality of transverse momentum dependent (TMD) fragmentation functions.

Gamberg, L. P.↗

Development of 325 MHZ Single Spoke Resonators for HINS at Fermilab: Recent Results

The Fermilab High Intensity Neutrino Source (HINS) Linac R&D program is building a 60 MeV superconducting H^{−} linac. The Linac incorporates SC solenoids, high power RF vector modulators and SC spoke-type accelerating cavities starting at 10 MeV. This will be the first application and demonstration of any of these technologies in a low-energy, high-intensity proton/H^{−} linac. The HINS effort is relevant to a high intensity, SC H^{−} linac that might serve the next generation of neutrino physics and muon storage ring/collider experiments. Three types of superconducting resonators are used in the linac front end. Single Spoke Resonators type-1 (SSR1) at β=0.2, Single Spoke Resonators type-2 (SSR2) at β=0.4 and Triple Spoke Resonators (TSR) at β=0.6. In this paper we describe the Buffer Chemical Polishing (BCP) performed on SSR1-#2 and the results of the cold tests for this bare cavity. We also describe the inelastic tune performed on cavity SSR1-#1, during this operation we measured also the spring constant and the frequency sensitivity of the end walls. We have also completed the design for the helium vessel that will be used to jacket SSR1 resonators and we present its design here.

Ristori, L.↗