Search NASA⌕ Search

Engineering topics

Mukundan, R.

Publications and source records attributed to Mukundan, R..

Durability of Pt-Co Alloy Polymer Electrolyte Fuel Cell Cathode Catalysts under Accelerated Stress Tests

The durability of Pt-Co alloy cathode catalysts supported on high surface area carbon is investigated by subjecting them to accelerated stress tests (ASTs). The catalysts had different initial Co contents and nanoparticle morphologies: a “spongy” porous morphology for the high-Co (H) content catalyst, and a fully alloyed crystalline morphology for the medium-Co (M) and low-Co (L) content catalysts. The specific activity of the catalysts depends on their initial Co content, morphology and nanoparticle size, and remained higher than 1000 μA/cm 2 -Pt after 27–50% Co loss. The H-catalyst electrode showed the smallest kinetic overpotentials (η c s ) due to higher initial Pt loading than the other two electrodes, but it had the fastest increase in ηcs with AST cycling due to lower Co retention; the L-catalyst electrode showed higher η c s due to a lower initial Pt loading, but had a smaller increase in η c s with aging due to higher Co retention; the M-catalyst electrode showed a similar increase in η c s with aging, but this increase was due to the combined effects of Co dissolution and electrochemically active surface area (ECSA) loss. In conclusion, the modeled increase in mass transfer overpotentials with aging correlates with the initial Pt loading, ECSA loss and the initial catalyst morphology

25 ENERGY STORAGE↗

PtCo Cathode Catalyst Morphological and Compositional Changes after PEM Fuel Cell Accelerated Stress Testing

Development of Pt catalysts alloyed with transition metals has led to a new class of state-of-the-art electrocatalysts for oxygen reduction at the cathode of proton exchange membrane fuel cells; however, the durability of Pt-based alloy catalysts is challenged by poor structural and chemical stability. There is a need for better understanding of the morphological and compositional changes that occur to the catalyst under fuel cell operation. In this work, we report in-depth characterization results of a Pt-Co electrocatalyst incorporated in the cathode of membrane electrode assemblies, which were evaluated before and after accelerated stress tests designed specifically to enhance catalyst degradation. Electron microscopy, spectroscopy, and 3D electron tomography analyses of the Pt-Co nanoparticle structures suggest that the small- and intermediate-sized Pt-Co particles, which are typically Pt-rich in the fresh condition, undergo minimal morphological changes, whereas intermediate- and larger-sized Pt-Co nanoparticles that exhibit a porous “spongy” morphology and initially have a higher Co content, transform into hollowed-out shells, which is driven by continuous leaching of Co from the Pt-Co catalysts. We further show how these primary Pt-Co nanoparticle morphologies group toward a lower Co, larger size portion of the size vs. composition distribution, and provide details of their nanoscale morphological features.

30 DIRECT ENERGY CONVERSION↗

Response characteristics of stable mixed-potential NH 3 sensors in diesel engine exhaust

Here, a mixed-potential, electrochemical sensor platform is extended to NH 3 sensing by the introduction of a new gold alloy working electrode. A planar, pre-commercial NH 3 sensor utilized LANL’s controlled interface approach, and a Pd-Au alloy working electrode was tested in exhaust of a GM 1.9 L diesel engine downstream of a diesel oxidation catalyst through a slipstream arrangement. A fraction of the exhaust was pulled across the sensor with a pump at 20 L/min. In order to simulate NH 3 slip inside of a full SCR emissions control system, NH 3 was injected immediately upstream of the sensor using a calibrated mass flow controller. The sensor response quantitatively tracked the NH 3 as measured via Fourier transform infrared (FTIR) analyzer. A calibration curve was obtained in the exhaust from an ammonia staircase response with the engine running at steady-state engine conditions resulting in low background concentrations of NO x and HC (<20 ppm) during calibration. Exhaust gas recirculation (EGR) switching and sweeps were used to evaluate the NH 3 sensor response under different amounts of total background NO x . The calibration curve was used to directly compare the [NH 3 ] calculated from sensor response to the gas phase composition measured via FTIR. In general, there was excellent quantitative agreement between the sensor response and the actual NH 3 in the exhaust gas, and fast response time such that transients (<5 ppm) could be easily discerned from baseline. A LANL pre-commercial NO x sensor was tested simultaneously with the NH 3 sensor and the extent of cross-sensitivity between the two sensors will be discussed.

47 OTHER INSTRUMENTATION↗

Dynamometer Testing of Planar Mixed-Potential Sensors

Mixed-potential sensors for vehicle on-board emissions monitoring applications have been fabricated in an automotive planar sensor configuration using high temperature ceramic co-fire methods. The sensing element consists of dense Pt and LaSrCrO electrodes and a porous 3 mol% YSZ electrolyte. This sensor construct exhibits preferential selectivity to NO x (NO+NO 2 ) when operated at a positive current bias. The performance of the planar sensors under engine-out conditions was recently evaluated at the Oak Ridge National Laboratory National Transportation Research Center on a GM 1.9L CIDI diesel engine. The sensor response qualitatively tracked transients in NO x measured via FTIR under transient engine operation. Additionally, quantitative correlation between sensor voltage response and total NO x concentration was obtained under steady-state engine speed and load while varying exhaust gas recirculation (EGR) levels.

42 ENGINEERING↗

Ice-Crystallization Kinetics in the Catalyst Layer of a Proton-Exchange-Membrane Fuel Cell

Nucleation and growth of ice in the catalyst layer of a proton-exchange-membrane fuel cell (PEMFC) are investigated using isothermal differential scanning calorimetry and isothermal galvanostatic cold-starts. Isothermal ice-crystallization rates and ice-nucleation rates are obtained from heat-flow and induction-time measurements at temperatures between 240 and 273 K for four commercial carbon-support materials with varying ionomer fraction and platinum loading. Measured induction times follow expected trends from classical nucleation theory and reveal that the carbon-support material and ionomer fraction strongly impact the onset of ice crystallization. Conversely, dispersed platinum particles play little role in ice crystallization. Following our previous approach, a nonlinear ice-crystallization rate expression is obtained from Johnson-Mehl-Avrami-Kolmogorov (JMAK) theory. A validated rate expression is now available for predicting ice crystallization within water-saturated catalyst layers. Using a simplified PEMFC isothermal cold-start continuum model, we compare cell-failure time predicted using the newly obtained rate expression to that predicted using a traditional thermodynamic-based approach. From this comparison, we identify conditions under which including ice-crystallization kinetics is critical and elucidate the impact of freezing kinetics on low-temperature PEMFC operation. The numerical model illustrates that cell-failure time increases with increasing temperature due to a longer required time for ice nucleation. Hence, ice-crystallization kinetics is critical when induction times are long (i.e., in the "nucleation-limited" regime for T > 263 K). Cell-failure times predicted using ice-freezing kinetics are in good agreement with the isothermal cold-starts, which also exhibit long and distributed cell-failure times for T > 263 K. These findings demonstrate a significant departure from cell-failure times predicted using the thermodynamic-based approach.

Dursch, T. J.↗

Hydrogen Fuel Quality

For the past 6 years, open discussions and/or meetings have been held and are still on-going with OEM, Hydrogen Suppliers, other test facilities from the North America Team and International collaborators regarding experimental results, fuel clean-up cost, modeling, and analytical techniques to help determine levels of constituents for the development of an international standard for hydrogen fuel quality (ISO TC197 WG-12). Significant progress has been made. The process for the fuel standard is entering final stages as a result of the technical accomplishments. The objectives are to: (1) Determine the allowable levels of hydrogen fuel contaminants in support of the development of science-based international standards for hydrogen fuel quality (ISO TC197 WG-12); and (2) Validate the ASTM test method for determining low levels of non-hydrogen constituents.

08 HYDROGEN↗