Synchronization and Rebound Effects in Residential Loads

Increasing fuel prices and capacity investment deferral place an increasing demand for peak reduction from distribution level systems. Residential and commercial devices, such as HVAC systems and water heaters, are increasingly involved in load control programs, and their use may generate synchronization and rebound effects, such as artificial peaks caused by device optimization. While there have been concerns over device synchronization, few studies quantify the extent of this effect with numerical values. In this study, we attempt to investigate whether control efforts result in device synchronization or rebound effects. We focus on three clustering methods – Ward’s clustering, Euclidean K-means, and Density-based spatial clustering of applications with noise – to evaluate the extent of synchronization of a fleet of water heaters and HVAC systems in Atlanta, Georgia. Our findings show that synchronization and rebound effects are present in the neighborhood’s water heaters, but none were found in the HVAC systems. Further, high usage water heaters are more susceptible to synchronization and rebound effects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ductless Heat Pump Energy Monitoring in a Cold Climate

In 2018, the City and Borough of Juneau, Alaska, set the goal of reaching 80% renewable energy for heating and transportation by 2045. An important factor to help reach this goal is energy-efficient home heating technologies such as ductless air- source heat pumps (DHPs), which rely on the local hydropower electric grid to provide space heating for an entire home or a main living area. To help residents reduce energy costs and move toward the community renewable energy goal, a team of local, state, and national partners joined together to run Thermalize Juneau 2021, an energy campaign that provided education, a simplified installation process, and a bulk purchase discount. Overall, the campaign enrolled 165 participants, resulting in 75 DHP installations and over 30 other energy efficiency improvements. To evaluate the reliability and energy use of the DHPs installed during the Thermalize Juneau campaign, researchers installed energy monitors on heat pumps of 14 participants and conducted interviews with homeowners. Data from two heating seasons (2021-2022 and 2022-2023) allowed researchers to examine the accuracy of pre-campaign energy savings predictions, establish energy savings for a small group of households, and provide insights on the energy use and occupant satisfaction of DHPs, which will help inform future heat pump deployment efforts in the area.

air source heat pump↗

Impact of Control on Availability and Cycling of Residential HVAC in a Real-World Experiment

Demand response is an important emerging part of smart grids and there is a large stream of research from theoretical and modeling perspectives. However, there is relatively little experimental evidence that could help researchers and building operators make informed decisions on best practices for modeling, developing, and deployment of control mechanisms. We contribute to the body of experimental research by providing numerical insights into the role and availability of residential HVAC systems for control. We share the findings on the duration of the cooling cycle, off cycle, and temperature settling time of HVAC systems from data collected from a smart neighborhood located in Atlanta, GA.

cycling↗

The Empirical Effect of Fleet Optimization on Synchronization and Rebound Effects in Heat Pump Water Heaters

Demand response is a growing concept in light of the internet of things and an increasing need for grid flexibility. Water heaters are one of the preferred devices for providing demand response for grid services and peak management due to their capability to store energy. The efficient use of water heaters for demand response requires consideration of the associated load effects such as synchronization of device schedules and rebound effect. These effects present a significant challenge. Despite the importance of the mentioned effects for water heater queuing and scheduling, there has been no effort to quantify and empirically validate their impact. This study attempts to address this gap by offering two methods - Ward clustering and Euclidean K-means - to evaluate the extent of synchronization in a fleet of 42 water heaters in Atlanta, GA. Using the aforementioned methods on the measured data, we find evidence of convergence of water heater loads as a result of optimization compared to an idle period and analyzed their impact.

demand response↗

Peak Reduction Using Mode Adjustment of Heat Pump Water Heaters in a Residential Neighborhood

Building electrification is putting pressure on distribution grid worldwide. Peak reduction is an important concern that can help reduce the growing stress and allow to defer investments in new capacity. Water heaters represent a convenient way of reducing peak because they are less dependent on weather, and their storage volume allows for asynchronous water heating and hot water use. Previous empirical studies investigated the ability of water heaters to reduce peak through the adjustment of the temperature setpoint. However, not all equipment vendors offer this option. This study aims at understanding the feasibility of peak reduction with an alternative configuration available in the market - by adjusting the device mode rather than temperature setpoint. The peak reduction methodology is tested in an occupied 46-townhome neighborhood located in Atlanta, GA. We find that peak shifting is possible with the adjustable mode approach, with the change in the peak load by 30-60%.

demand response↗

Experimental Evidence on Latency in a Fleet of Controllable Water Heaters

Demand response is an important emerging part of smart grids with wide coverage in theoretical and modeling research. However, experimental evidence on the real-life behavior of controllable loads is still limited. We present observations regarding latency and communication aspects of the operation on a fleet of residential water heaters in a smart neighborhood in Atlanta, GA. Our analysis shows that latency in water heaters is not constant and does not follow a Gaussian distribution. We also find that there is a systematic relationship between latency and hour of the day. Latency was found to increase during morning and evening hours compared to the afternoon. These findings could help better plan deployment of control for demand response programs. Understanding delays associated with controlling smart devices is crucial for proper design and algorithm development for optimization, frequency of dispatch, and override detection.

communication delay↗

Using Synchronization as an Indicator of Controllability in a Fleet of Water Heaters

Peak reduction is an important concern that can help reduce the growing stress on distribution grid and allow to defer investments in new capacity. However, the growing concern for customer privacy and comfort may impact the performance of load control for residential devices. Water heaters represent a convenient way of reducing peak due to their ability to store thermal energy for future use. In this paper, we developed a methodology to help utilities gain more insight with respect to the impact of load control efforts for shaving peak with no necessary information about the water heaters except the device status (on/off). To this end, we use a fleet of water heaters in a controlled residential neighborhood in Atlanta, GA. Our findings show that convergence in device status can serve as a proxy for peak shifting during hours of the evening peak.

demand response↗

Barriers to Broader Utilization of Fault Detection Technologies for Improving Residential HVAC Equipment Efficiency

Faults in residential heating, ventilating, and air conditioning (HVAC) equipment may occur due to poor installation practices or develop over time, and these faults can negatively impact system efficiency, thermal comfort, and equipment lifespan. Automated fault detection and diagnostic (AFDD) technologies identify energy wasting HVAC faults, such as low indoor airflow and improper refrigerant charge, and guide technicians in improving system efficiency. For residential HVAC, AFDD consists of a range of fault detecting and diagnostic capabilities, sensor configurations, and target applications. AFDD technology can either be permanently installed by the original equipment manufacturer (OEM) using embedded sensors or as an add-on product either during or after installation. Additionally, several advanced installation tools and refrigerant gauge sets include AFDD features for temporary use during equipment installation and tune-ups. Some technologies can detect a fault but have limited diagnostic capabilities. For example, a single-point measurement from the home's thermostat or energy monitor can provide certain fault detection capability by analyzing the equipment runtime or energy consumption. These technologies, though limited at determining the cause of a given fault, may have significant energy savings potential due to their low cost and prevalence in the residential HVAC market. Despite the potential benefits, fault detection technologies face many technical and market barriers preventing broad adoption. Beyond the cost barriers due to the added sensor requirements and technology development, fault detection technologies face many implementation and adoption barriers such as installer training, customer awareness, standardized communication protocols, and methods of test for evaluating accuracy. The purpose of this whitepaper is to characterize market and technical barriers impeding broader utilization of fault detection technology for residential HVAC energy efficiency applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dataset of ultralow temperature refrigeration for COVID 19 vaccine distribution solution

Abstract Most COVID-19 vaccines require temperature control for transportation and storage. Two types of vaccine have been developed by manufacturers (Pfizer and Moderna). Both vaccines are based on mRNA and lipid nanoparticles requiring low temperature storage. The Pfizer vaccine requires ultra-low temperature storage (−80 °C to −60 °C), while the Moderna vaccine requires −30 °C storage. However, the last stage of distribution is quite challenging, especially for rural or suburban areas, where local towns, pharmacy chains and hospitals may not have the infrastructure required to store the vaccine at the required temperature. In addition, there is limited data available to address ancillary challenges of the distribution framework for both transportation and storage stages, including safety concerns due to human exposure to large amounts of CO 2 from dry-ice sublimation, issues due to the pressure increase caused by dry-ice sublimation, and the potential issue caused by non-uniform cryogenic temperatures. As such, there is a need for test dataset to assist the development of a quick, effective, secure, and safe solution to mitigate the challenges faced by vaccine distribution logistics.

60 APPLIED LIFE SCIENCES↗

Dataset of low global warming potential refrigerant refrigeration system for fault detection and diagnostics

Abstract HVAC and refrigeration system fault detection and diagnostics (FDD) has attracted extensive studies for decades; however, FDD of supermarket refrigeration systems has not gained significant attention. Supermarkets consume around 50 kWh/ft 2 of electricity annually. The biggest consumer of energy in a supermarket is its refrigeration system, which accounts for 40%–60% of its total electricity usage and is equivalent to about 2%–3% of the total energy consumed by commercial buildings in the United States. Also, the supermarket refrigeration system is one of the biggest consumers of refrigerants. Reducing refrigerant usage or using environmentally friendly alternatives can result in significant climate benefits. A challenge is the lack of publicly available data sets to benchmark the system performance and record the faulted performance. This paper identifies common faults of supermarket refrigeration systems and conducts an experimental study to collect the faulted performance data and analyze these faults. This work provides a foundation for future research on the development of FDD methods and field automated FDD implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗