Search NASA⌕ Search

Engineering topics

Murata-Seawalt, D.

Publications and source records attributed to Murata-Seawalt, D..

The Space Telescope imaging spectrograph 2048 CCD and its characteristics

Development of a 2048-squared CCD for a second-generation Space Telescope instrument has produced some very encouraging devices. The first experimental lot of 10 devices have very few defects, dark currents of less than 40 electrons/pixel/hour at -80 C, readout noise levels of less than 4 electrons rms and excellent charge transfer efficiency at signal levels of less than 10 electrons.

Delamere, W. A.↗

Proton radiation effects on multi-pinned-phased CCDs

Three Tektronix 1024 x 1024 multi-pinned-phased (MPP) charge coupled devices were irradiated with protons to obtain data on CCD performance degradation in a proton radiation environment. The devices were irradiated with a spectrum of energies up to 120 MeV, simulating the total radiation dose of a long-term space experiment. Basic parameters such as charge transfer efficiency, dark current, noise, and full well were measured before and after irradiation. A test was also performed to determine the effectiveness of various thicknesses of tantalum shielding in protecting the CCD from damage. Dark current increase and CTE degradation were the most noticeable effects of proton radiation. This paper will present the objectives, test data, and conclusions of the proton testing, and will identify future testing to be performed.

Murata-Seawalt, D.↗

Charge transfer efficiency measurements at low signal levels on STIS/SOHO TK1024 CCD's

Charge transfer efficiency (CTE) test methods are reviewed, and the results and conclusions of the tests are given. The test methods have been utilized to describe the CTE characteristics of the Tektronix 1024 by 1024 CCD to optimize low dark current, low readout noise, and high CTE at low signal levels. CTE modelling is described, and three test methods are set forth and compared. The Fe-55 X-ray response method utilizes the response of a CCD to X-ray photons from the radioactive source Fe-55. The extended pixel edge response method employs the measurement of the charge lost to successive pixels by a known initial signal as it is shifted through the array. The charge injection method consists of charge injection through the output amplifier reset transistor. These measurements were performed on several devices with known CTEs. The CTEs are found to be in agreement for the three methods, making application and test requirements the principal criteria for their use.

Orbock, J. D.↗