Search NASA⌕ Search

Engineering topics

Murphy, D. V.

Publications and source records attributed to Murphy, D. V..

Overview and Status of the Lunar Laser Communication Demonstration

The Lunar Laser Communication Demonstration (LLCD), a project being undertaken by MIT Lincoln Laboratory, NASA's Goddard Space Flight Center, and the Jet Propulsion Laboratory, will be NASA's first attempt to demonstrate optical communications between a lunar orbiting spacecraft and Earth-based ground receivers. The LLCD space terminal will be flown on the Lunar Atmosphere and Dust Environment Explorer (LADEE) spacecraft, presently scheduled to launch in 2013. LLCD will demonstrate downlink optical communications at rates up to 620 Mbps, uplink optical communications at rates up to 20 Mbps, and two-way time-of-flight measurements with the potential to perform ranging with sub-centimeter accuracy. We describe the objectives of the LLCD program, key technologies employed in the space and ground terminals, and show the status of development of the several systems.

deep space communications↗

Rotational cars application to simultaneous and multiple-point temperature and concentration determination in a turbulent flow

Coherent Anti-stokes Raman Scattering (CARS) from the pure rotational Raman lines of N2 is employed to measure the instantaneous rotational temperature of N2 gas at room temperature and below with good spatial resolution. A broad-bandwidth dye laser is used to obtain the entire rotational spectrum from a signal laser pulse; the CARS signal is then dispersed by a spectrograph and recorded on an optical multichannel analyzer. A best-fit temperature is found in several seconds with the aid of a computer for each experimental spectrum by a least squares comparison with calculated spectra. The model used to calculate the theoretical spectra incorporates the temperature and pressure dependence of the pressure-broadened rotational Raman lines, includes the nonresonant background susceptibility, and assumes that the pump laser has a finite linewidth. Temperatures are fit to experimental spectra recorded over the temperature range of 135 to 296K, and over the pressure range of 0.13 to 15.3 atm. In addition to the spatially resolved single point work, we have used multipoint CARS to obtain information from many spatially resolved volume elements along a cylindrical line (0.1 x 0.1 x 2.0 mm). We also obtained qualitative information on the instantaneous species concentration and temperature at 20 spatially resolved volume elements (0.1 x 0.1 x 0.1 mm) along a line.

Snow, J. B.↗

Rotational CARS application to simultaneous and multiple-point temperature and concentration determination in a turbulent flow

Coherent anti-Stokes Raman scattering (CARS) from the pure rotational Raman lines of N2 is employed to measure the instantaneous (approximately 10 ns) rotational temperature of N2 gas at room temperature and below with good spatial resolution (0.2 x 0.2 x 3.0 cu mm). A broad bandwidth dye laser is used to obtain the entire rotational spectrum from a single laser pulse; the CARS signal is then dispersed by a spectrograph and recorded on an optical multichannel analyzer. A best fit temperature is found in several seconds with the aid of a computer for each experimental spectrum by a least squares comparison with calculated spectra. The model used to calculate the theoretical spectra incorporates the temperature and pressure dependence of the pressure-broadened rotational Raman lines, includes the nonresonant background susceptibility, and assumes that the pump laser has a finite linewidth. Temperatures are fit to experimental spectra recorded over the temperature range of 135 to 296 K, and over the pressure range of .13 to 15.3 atm.

Snow, J. B.↗

Single-pulse broad-band rotational CARS thermometry of cold N2 gas

Coherent anti Stokes Raman scattering (CARS) from the pure rotational Raman lines of N2 was employed to measure the instantaneous (10 nsec) rotational temperature of the gas at room temperature and below. An entire rotational CARS spectrum was generated by a single laser pulse using a broad bandwidth dye laser and was recorded on an optical multichannel analyzer. A best fit temperature obtained for individual experimental spectra by comparison with calculated spectra. Good agreement between CARS temperatures and thermocouple temperatures was observed.

Chang, R. K.↗