Shape memory embolectomy devices and systems

An embolectomy device comprised of an expansion unit and a support unit is disclosed. The expansion unit can be actuated in response to one or more external stimuli, and the support unit, located proximately to the expansion unit, provides a force to hold the expansion unit in place and to further induce the expansion unit's radial expansion. The radial expansion of the expansion unit causes the expansion unit to physically contact a blood clot, enabling the blood clot to be removed. In some embodiments, the expansion unit can be fabricated from a shape memory polymer foam. In some embodiments the support unit can be fabricated from any elastic material including, without limitation, shape memory alloys.

59 BASIC BIOLOGICAL SCIENCES↗

Shape memory embolectomy devices and systems

An embolectomy device comprised of an expansion unit and a support unit is disclosed. The expansion unit can be actuated in response to one or more external stimuli, and the support unit, located proximately to the expansion unit, provides a force to hold the expansion unit in place and to further induce the expansion unit's radial expansion. The radial expansion of the expansion unit causes the expansion unit to physically contact a blood clot, enabling the blood clot to be removed. In some embodiments, the expansion unit can be fabricated from a shape memory polymer foam. In some embodiments the support unit can be fabricated from any elastic material including, without limitation, shape memory alloys.

Szafron, Jason↗

Porous media properties of reticulated shape memory polymer foams and mock embolic coils for aneurysm treatment

Background: Shape memory polymer (SMP) foams are being investigated as an alternative aneurysm treatment method to embolic coils. The goal of both techniques is the reduction of blood flow into the aneurysm and the subsequent formation of a stable thrombus, which prevents future aneurysm rupture. The purpose of this study is to experimentally determine the parameters, permeability and form factor, which are related to the flow resistance imposed by both media when subjected to a pressure gradient. Methods: The porous media properties—permeability and form factor—of SMP foams and mock embolic coils (MECs) were measured with a pressure gradient method by means of an in vitro closed flow loop. We implemented the Forchheimer-Hazen-Dupuit-Darcy equation to calculate these properties. Mechanically-reticulated SMP foams were fabricated with average cell sizes of 0.7E-3 and 1.1E-3 m, while the MECs were arranged with volumetric packing densities of 11-28%. Results: The permeability of the SMP foams was an order of magnitude lower than that of the MECs. The form factor differed by up to two orders of magnitude and was higher for the SMP foams in all cases. The maximum flow rate of all samples tested was within the inertial laminar flow regime, with Reynolds numbers ranging between 1 and 35. Conclusions: The SMP foams impose a greater resistance to fluid flow compared to MECs, which is a result of increased viscous and inertial losses. These results suggest that aneurysms treated with SMP foam will have flow conditions more favorable for blood stasis than those treated with embolic coils having packing densities ≤ 28%.

36 MATERIALS SCIENCE↗