Search NASA⌕ Search

Engineering topics

Musico, P.

Publications and source records attributed to Musico, P..

At least 19 records

Electro- and photoproduction of muon pairs with $$\mu $$CLAS12: double deeply virtual compton scattering, timelike compton scattering, and $$J/\psi $$ production

The CEBAF Large Acceptance Spectrometer for operation at 12 GeV (CLAS12) at the Thomas Jefferson National Accelerator Facility has played a central role in advancing the understanding of nucleon and nuclear structure. As increasingly precise data become available, new physics opportunities emerge that extend beyond the current capabilities of CLAS12. In this article, a program to explore the quark and gluon structure of the nucleon through di-muon electro- and photoproduction is presented. Its primary focus is the measurement of beam-spin asymmetries in Double Deeply Virtual Compton Scattering, . By independently varying the incoming and outgoing photon virtualities and momentum transfer, the DDVCS measurement provides access to the Generalized Parton Distributions over their full three-dimensional phase space, extending beyond the kinematic constraints of Deeply Virtual Compton Scattering and Timelike Compton Scattering. In addition, the large acceptance and high luminosity of the CLAS12 experiment will enable precision measurements of near-threshold production and high-statistics studies of Timelike Compton Scattering.

Alvarado, J. S.↗

Search for dark matter annual modulation with DarkSide-50

Dark matter may induce an event in an Earth-based detector, and its event rate is predicted to show an annual modulation as a result of the Earth’s orbital motion around the Sun. We searched for this modulation signature using the ionization signal of the DarkSide-50 liquid argon time projection chamber. No significant signature compatible with dark matter is observed in the electron recoil equivalent energy range above 40 eV ee , the lowest threshold ever achieved in such a search. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Long-term temporal stability of the DarkSide-50 dark matter detector

The stability of a dark matter detector on the timescale of a few years is a key requirement due to the large exposure needed to achieve a competitive sensitivity. It is especially crucial to enable the detector to potentially detect any annual event rate modulation, an expected dark matter signature. Here, in this work, we present the performance history of the DarkSide-50 dual-phase argon time projection chamber over its almost three-year low-radioactivity argon run. In particular, we focus on the electroluminescence signal that enables sensitivity to sub-keV energy depositions. The stability of the electroluminescence yield is found to be better than 0.5%. Finally, we show the temporal evolution of the observed event rate around the sub-keV region being consistent to the background prediction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for low mass dark matter in DarkSide-50: the bayesian network approach

Abstract We present a novel approach for the search of dark matter in the DarkSide-50 experiment, relying on Bayesian Networks. This method incorporates the detector response model into the likelihood function, explicitly maintaining the connection with the quantity of interest. No assumptions about the linearity of the problem or the shape of the probability distribution functions are required, and there is no need to morph signal and background spectra as a function of nuisance parameters. By expressing the problem in terms of Bayesian Networks, we have developed an inference algorithm based on a Markov Chain Monte Carlo to calculate the posterior probability. A clever description of the detector response model in terms of parametric matrices allows us to study the impact of systematic variations of any parameter on the final results. Our approach not only provides the desired information on the parameter of interest, but also potential constraints on the response model. Our results are consistent with recent published analyses and further refine the parameters of the detector response model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The CLAS12 Ring Imaging Cherenkov Detector

A ring imaging Cherenkov (RICH) detector has been installed in the CLAS12 spectrometer at Jefferson Laboratory (JLab) to provide kaon identification in the momentum range between 3 GeV/c and 8 GeV/c. The detector adopts a hybrid optics solution with aerogel radiator, light planar and spherical mirrors, and highly segmented photon detectors. We report here on the design, construction, and initial performance of the RICH during the commissioning of the detector and the first physics data taking period

PID detectors↗

The CLAS12 Forward Tagger

This document presents the technical layout and the performance of the CLAS12 Forward Tagger (FT). The FT, composed of an electromagnetic calorimeter based on PbWO$_4$ crystals (FT-Cal), a scintillation hodoscope (FT-Hodo), and several layers of Micromegas trackers (FT-Trk), has been designed to detect electrons and photons scattered at polar angles from 2$^\circ$ to 5$^\circ$ and to meet the physics goals of the hadron spectroscopy program and other experiments running with the CLAS12 spectrometer in Hall B.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single photon detection with the multi-anode CLAS12 RICH detector

Recently, the first module of the hybrid-optics large-area CLAS12 RICH at JLab has been put into operation using for the first time the well known Hamamatsu H8500 MAPMT and the new single-photon dedicated H12700, for a total of about 400 MAPMTs and 25000 pixels. The photon detector must efficiently detect single photons in the visible and near-UV light region, provide a fast response for background rejection and pattern recognition, and have a spatial resolution of less than 1 cm over an area of ≈1 m 2 . Each front-end readout unit is composed of three electronic boards with specific tasks directly connected to groups of 2 or 3 sensors. The core of the readout is composed of MAROC3 and FPGA chips. The MAROC3 chip is able to discriminate the 64 signals from one MAPMT and to produce 64 corresponding binary outputs with 100% efficiency starting at a small fraction of the single-photon signal, while the FPGA chip provides 1 ns TDC capability with 8 μs maximum latency and acts as a DAQ controller. The system is created to be almost dead-time free at the foreseen 20 kHz CLAS12 trigger rate. The best working conditions for single-photon detection have been studied at laser stands, test beams, and with the JLab electron beam data. A report of the photon detector preparation, commissioning and operation is here discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The large-area hybrid-optics CLAS12 RICH: Assembling, commissioning and first data-taking

Here, the first module of a Ring Imaging Cherenkov detector has been recently installed on the CLAS12 spectrometer at the Jefferson Lab (JLab) to provide the experiment with kaon identification in the momentum range between 3 and 8 GeV/c. The detector adopts a hybrid optics solution with aerogel radiator, light planar and spherical mirrors and highly-segmented photon detectors. We report here on the assembly and installation of the RICH and we show the first preliminary results obtained during the commissioning of the detector and the first physics data taking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A radial time projection chamber for α detection in CLAS at JLab

A new Radial Time Projection Chamber (RTPC) was developed at the Jefferson Laboratory to track low-energy nuclear recoils to measure exclusive nuclear reactions, such as coherent deeply virtual Compton scattering and coherent meson production off 4 He. In 2009, we carried out these measurements using the CEBAF Large Acceptance Spectrometer (CLAS) supplemented by the RTPC positioned directly around a gaseous 4 He target, allowing a detection threshold as low as 12 MeV for 4 He. This work discusses the design, principle of operation, calibration methods and performances of this RTPC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CALIS—A CALibration Insertion System for the DarkSide-50 dark matter search experiment

This paper describes the design, fabrication, commissioning and use of a CALibration source Insertion System (CALIS) in the DarkSide-50 direct dark matter search experiment. CALIS deploys radioactive sources into the liquid scintillator veto to characterize the detector response and detection efficiency of the DarkSide-50 Liquid Argon Time Projection Chamber, and the surrounding 30 t organic liquid scintillator neutron veto. It was commissioned in September 2014 and has been used successfully in several gamma and neutron source campaigns since then. A description of the hardware and an excerpt of calibration analysis results are given below.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of argon response and light detection in the DarkSide-50 dual phase TPC

A Geant4-based Monte Carlo package named G4DS has been developed to simulate the response of DarkSide-50, an experiment operating since 2013 at LNGS, designed to detect WIMP interactions in liquid argon. In the process of WIMP searches, DarkSide-50 has achieved two fundamental milestones: the rejection of electron recoil background with a power of ~10 7 , using the pulse shape discrimination technique, and the measurement of the residual 39 Ar contamination in underground argon, ~3 orders of magnitude lower with respect to atmospheric argon. These results rely on the accurate simulation of the detector response to the liquid argon scintillation, its ionization, and electron-ion recombination processes. This work provides a complete overview of the DarkSide Monte Carlo and of its performance, with a particular focus on PARIS, the custom-made liquid argon response model.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of low electric fields on alpha scintillation light yield in liquid argon

Measurements were made of scintillation light yield of alpha particles from the $^{222}$Rn decay chain within the DarkSide-50 liquid argon time projection chamber. Furthermore, the light yield was found to increase as the applied electric field increased, with alphas in a 200 V/cm electric field exhibiting a 2% increase in light yield compared to alphas in no field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The large-area hybrid-optics RICH detector for the CLAS12 spectrometer

A large area ring-imaging Cherenkov detector has been designed to provide clean hadron identification capability in the momentum range from 3 GeV/c to 8 GeV/c for the CLAS12 experiments at the upgraded 12 GeV continuous electron beam accelerator facility of Jefferson Lab to study the 3D nucleon structure in the yet poorly explored valence region by deep-inelastic scattering, and to perform precision measurements in hadronization and hadron spectroscopy. The adopted solution foresees a novel hybrid optics design based on an aerogel radiator, composite mirrors and densely packed and highly segmented photon detectors. Cherenkov light will either be imaged directly (forward tracks) or after two mirror reflections (large angle tracks). Finally, the preliminary results of individual detector component tests and of the prototype performance at test-beams are reported here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The DarkSide experiment: Present status and future

Here, DarkSide is a multi-stage program devoted to direct searches of Dark Matter particles with detectors based on double phase liquid Argon Time Projection Chamber. The DarkSide-50 setup is running underground at the Laboratori Nazionali del Gran Sasso. First it was operated with Atmospheric Argon and during that run (1422 ± 67) kg×d of truly background-free exposure has been accumulated. Obtained data made it possible to set a 90% C.L. upper limit on the WIMP-nucleon cross section of 6.1 × 10 –44 cm 2 (for a WIMP mass of 100 GeV/c 2 ). Presently the detector is filled with Underground Argon, which is depleted in 39 Ar by a factor of (1.4 ± 0.2)×10 3 with respect to Atmospheric Argon. Acquired so far (2616 ± 43) kg×d (71 live days) in combination with the data from the Atmospheric Argon run give us the 90% C.L. upper limit on the WIMP-nucleon spin-independent cross section of 2.0×10 –44 cm 2 for a WIMP mass of 100 GeV/c 2 . Up to date this is the best limit obtained with an argon target.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The DarkSide-50 Experiment: a Liquid Argon Target for Dark Matter Particles

The DarkSide-50 experiment, located at the “Laboratori Nazionali del Gran Sasso (INFN)”, is based on low-radioactivity argon double phase time projection chamber, surrounded by an active liquid scintillator veto, designed for the zero background achievement. The liquid argon features sufficient self shielding and easy scalability to multi-tons scale. The impressive reduction of the 39 Ar isotope (compared to the atmospheric argon), along with the excellent pulse shape discrimination, make this technology a possible candidate for the forthcoming generation of multi-ton Dark Matter experiments.

79 ASTRONOMY AND ASTROPHYSICS↗