Search NASA⌕ Search

Engineering topics

Myers, Kurt S

Publications and source records attributed to Myers, Kurt S.

High Penetration Microgrids Providing Grid Stability Using Frequency-Watt Control Presentation

The U.S. grid is rapidly transitioning towards utilizing inverter-based renewable energy resources such as solar, wind, and batteries, reducing the carbon emission footprint.Inverter-based microgrid control architectures remain a critical focus to address power system stability issues in future high penetration markets lacking spinning generation assets. Idaho National Laboratory (INL) is researching an active layered inverter based frequency-Watt control scheme that provides distribution level stability in high-penetration markets where grid inertia is lacking. Hardware in the loop case study was implemented using INL’s Microgrid Testbed to combat scalable frequency deviations ranging from 60 Hz down to 50 Hz initialized by a hydropower model implementing step loads using a 540-kW grid emulator. Our research findings demonstrate the importance of distribution level, inverter-based active frequency-Watt controls utilizing a battery energy storage system (BESS) to provide adequate frequency support at the point of common coupling without major power infrastructure upgrades.

13 HYDRO ENERGY↗

High-Penetration Microgrids Providing Grid Stability Using Frequency Watt Control

The U.S. grid is rapidly transitioning towards utilizing inverter-based renewable energy resources such as solar, wind, and batteries, reducing the carbon emission footprint. Inverter-based microgrid control architectures remain a critical focus to address power system stability issues in future high penetration markets lacking spinning generation assets. Idaho National Laboratory (INL) is researching an active layered inverter based frequency-Watt control scheme that provides distribution level stability in high-penetration markets where grid inertia is lacking. Hardware in the loop case study was implemented using INL’s Microgrid Testbed to combat scalable frequency deviations ranging from 60 Hz down to 50 Hz initialized by a hydropower model implementing step loads using a 540-kW grid emulator. Our research findings demonstrate the importance of distribution level, inverter-based active frequency-Watt controls utilizing a battery energy storage system (BESS) to provide adequate frequency support at the point of common coupling without major power infrastructure upgrades.

14 SOLAR ENERGY↗

Investigating Net-Zero Carbon Microgrids for DOE’s National Laboratory Facilities: A Case Study for Idaho National Laboratory

The concept of net-zero carbon microgrids (NZMs) has received significant interest in recent years considering its promises to provide both energy resilience and carbon reduction. This paper investigates the practical constraints of NZM deployment in a government facility, exploring various cases revolving around the objectives of cost, emission, and energy resilience. The technoeconomic results for one of the Idaho National Laboratory (INL) facilities are discussed to identify a practical and economic approach to achieve the net-zero target considering both present and future scenarios. The study shows the carbon reduction, resilience, and economic success of net-zero initiatives are tied directly to the energy portfolio of its electricity provider. The NZMs typically required a hybrid mix of renewable generation and storage assets to maximize onsite clean generation and to provide reliable power during grid outages. Besides supporting the ongoing net-zero effort at INL, this work also provides a framework that can be directly used in other facilities aspiring to become a net zero in the future.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

INVESTIGATION OF A DYNAMIC POWER LINE RATING CONCEPT FOR IMPROVED WIND ENERGY INTEGRATION OVER COMPLEX TERRAIN

Dynamic Line Rating (DLR) is a smart grid technology that allows the rating of power line to be based on real-time conductor temperature dependent on local weather conditions. In current practice overhead power lines are generally given a conservative rating based on worst case weather conditions. Using historical weather data collected over a test bed area, we demonstrate there is often additional transmission capacity not being utilized with the current static rating practice. We investigate a new dynamic line rating methodology using computational fluid dynamics (CFD) to determine wind conditions along transmission lines at dense intervals. Simulated results are used to determine conductor temperature by calculating the transient thermal response of the conductor under variable environmental conditions. In calculating the conductor temperature, we use both a calculation with steady-state assumption and a transient calculation. Under low wind conditions, steady-state assumption predicts higher conductor temperatures that could lead to curtailments, whereas transient calculations produce conductor temperatures that are significantly lower, implying the availability of additional transmission capacity.

13 HYDRO ENERGY↗

Transformer Efficiency Assessment - Okinawa, Japan

The US Army Engineering & Support Center, Huntsville (USAESCH), and the US Marine Corps Base (MCB), Okinawa, Japan retained Idaho National Laboratory (INL) to conduct a Transformer Efficiency Assessment of “key” transformers located at multiple military bases in Okinawa, Japan. The purpose of this assessment is to support the Marine Corps Base, Okinawa in evaluating medium voltage distribution transformers for potential efficiency upgrades. The original scope of work included the MCB providing actual transformer nameplate data, manufacturer’s factory test sheets, electrical system data (kWh), demand data (kWd), power factor data, and electricity cost data. Unfortunately, the MCB’s actual data is not available and therefore making it necessary to de-scope the original assessment. Note: Any similar nameplate data, photos of similar transformer nameplates, and basic electrical details from one-line drawings (provided by MCB) are not a replacement for actual load loss test data. It is recommended that load measurements are performed on the high and low sides of transformers to better quantify actual load losses, demand data, and power factor data. We also recommend that actual data, when available, be inserted by MCB Okinawa where assumptions have been made and then the LCC analysis updated. This report covers a generalized assessment of modern U.S. transformers in a three level efficiency category, Low-Level efficiency, Medium-Level efficiency, and High-Level efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗