Search NASA⌕ Search

Engineering topics

Myers, Tanya L

Publications and source records attributed to Myers, Tanya L.

SERDP PFAS 2.0 - An infrared spectral database for gas-phase quantitation of volatile per- and polyfluoroalkyl substances (PFAS)

We report the construction of a database of vetted infrared spectra specifically targeting volatile fluorocarbon gases that may be emitted during thermal treatment of per- and polyfluoroalkyl substances (PFAS) to assist understanding of treatment processes and improve quantification. To populate this database, protocols derived from the Pacific Northwest National Laboratory (PNNL) infrared spectral database are used, curtailing the species selection for this data set. Each spectrum in the database is a weighted average derived from 10 or more individual measurements at different partial pressures (static method) or flow rates (dissemination method) to yield good fidelity of both strong and weak infrared signatures, with each composite spectrum ranging from = 6500 cm-1 to = 600 cm-1 with an apodized resolution of 0.112 cm-1. This resolution was chosen to fully resolve all spectral features, recognizing that atmospheric pressure broadening results in nearly all ro-vibrational lines having linewidths = 0.1 cm-1. As an example case, application of the database is demonstrated via identification and quantification of dominant 1H-perfluoroheptane and perfluorohept-1-ene fluorocarbon products resulting from thermal decomposition of perfluorooctanoate (PFOA) below 450 °C.

Infrared, Gas-phase spectra, FTIR, Spectral databa↗

SERDP PFAS Database

The PNNL-PFAS database was constructed to provide quantitative infrared spectra of per- and polyfluoroalkyl substances (PFAS) in the gas phase. These fluorine-rich, organic compounds have been used as non-flammable solvents, cleaning agents, and in the manufacture of a diverse variety of consumer products. Due to their widespread use and relative inertness, PFAS have accumulated in the natural environment, and exposure to these chemicals may be linked to harmful health effects. Development of methods for detecting and remediating PFAS contamination are thus active areas of research. This database supports PFAS investigations where gas-phase infrared signatures may be measured (e.g., during treatment by thermal decomposition). The database currently contains infrared spectra for 15 compounds; these were selected based on the potential of these compounds being thermal degradation products of the manufactured chemicals mentioned above. • Additional compounds will be added to the database in the future. • Additional information about the database may be obtained from [link to future paper about the PFAS database].

PFAS, infrared(IR)spectroscopy, DATABASE, FTIR, sp↗

A modular architecture for multi-channel external cavity quantum cascade laser-based chemical sensors: a systems approach

A multi-channel laser-based chemical sensor platform is presented, in which a modular architecture allows the exchange of complete sensor channels without disruption to overall operation. Each sensor channel contains custom optical and electronics packages, which can be selected to access laser wavelengths, interaction path lengths and modulation techniques optimal for a given application or mission. Although intended primarily to accommodate mid-infrared (MIR) external cavity quantum cascade lasers (ECQCLs)and astigmatic Herriott cells, channels using visible or near infrared (NIR) lasers or other gas cell architectures can also be used, making this a truly versatile platform. Analog and digital resources have been carefully chosen to facilitate small footprint, rapid spectral scanning, ow-noise signal recovery, failsafe autonomous operation, and in-situ chemometric data analysis, storage and transmission. Results from the demonstration of a two-channel version of this platform are also presented.

99 GENERAL AND MISCELLANEOUS↗

Fiber Delivery of mid-IR lasers

Fiber optics for the visible to near infrared (NIR) wavelength regimes (i.e. = 0.42 {mu}m) have proven to be extremely useful for a myriad of applications such as telecommunications, illumination, and sensors because they enable convenient, compact, and remote delivery of laser beams. Similarly, there is a need for fiber optics operating at longer wavelengths. For example, systems operating in the mid-IR regime (i.e., = 314 {mu}m) are being developed to detect trace molecular species with far-reaching applications, such as detecting explosives on surfaces, pollutants in the environment, and biomarkers in the breath of a patient. Furthermore, with the increasing availability of quantum cascade lasers (QCLs) which are semiconductor lasers that operate in the mid-IR regime additional uses are rapidly being developed. Here, we describe the development of hollow-core fibers for delivery of high-quality mid-IR laser beams across a broad spectral range.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hollow Core Fiber Optics for Mid-Wave and Long-Wave Infrared Spectroscopy

The development and testing of hollow core glass waveguides (i.e., fiber optics) for use in Long-Wave Infrared (LWIR) spectroscopy systems is described. LWIR fiber optics are a key enabling technology needed to improve the utility and effectiveness of trace chemical detection systems based in the 8 to 12 micron region. This paper focuses on recent developments in hollow waveguide technology geared specifically for LWIR spectroscopy, including a reduction in both the length dependent loss and the bending loss while maintaining relatively high beam quality. Results will be presented from tests conducted with a Quantum Cascade Laser.

99 GENERAL AND MISCELLANEOUS↗

Single-mode, narrow-linewidth external cavity quantum cascade laser through optical feedback from a partial-reflector

An external-cavity (EC) quantum cascade (QC) laser using optical feedback from a partial-reflector is reported. With this configuration, the otherwise multi-mode emission of a Fabry-Perot QC laser was made single-mode with optical output powers exceeding 40 mW. A mode-hop free tuning range of 2.46 cm-1 was achieved by synchronously tuning the EC length and QC laser current. The linewidth of the partial-reflector EC-QC laser was measured for integration times from 100 μs to 4 s, and compared to a distributed feedback QC laser. Linewidths as small as 480 kHz were recorded for the EC-QC laser

(140.3410) Laser resonators↗

Highly sensitive chemical detection in the field

Optical sensing methods, in particular infrared absorption spectroscopy combined with quantum cascade lasers (QCLs), are highly suited for the detection of chemicals since they enable rapid detection and are amenable for autonomous operation in a compact and rugged package.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser-based Sensors for Chemical Detection

Stand-off detection of hazardous materials ensures that the responder is located at a safe distance from the suspected source. Remote detection and identification of hazardous materials can be accomplished using a highly sensitive and portable device, at significant distances downwind from the source or the threat. Optical sensing methods, in particular infrared absorption spectroscopy combined with quantum cascade lasers (QCLs), are highly suited for the detection of chemical substances since they enable rapid detection and are amenable for autonomous operation in a compact and rugged package. This talk will discuss the sensor systems developed at Pacific Northwest National Laboratory and will discuss the progress to reduce the size and power while maintaining sensitivity to enable stand-off detection of multiple chemicals.

47 OTHER INSTRUMENTATION↗

FY2008 Calibration Systems Final Report

The Calibrations project has been exploring alternative technologies for calibration of passive sensors in the infrared (IR) spectral region. In particular, we have investigated using quantum cascade lasers (QCLs) because these devices offer several advantages over conventional blackbodies such as reductions in size and weight while providing a spectral source in the IR with high output power. These devices can provide a rapid, multi-level radiance scheme to fit any nonlinear behavior as well as a spectral calibration that includes the fore-optics, which is currently not available for on-board calibration systems.

47 OTHER INSTRUMENTATION↗