Search NASA⌕ Search

Engineering topics

Myers, Tanya L.

Publications and source records attributed to Myers, Tanya L..

Revisiting the Anisotropic Complex Refractive Indices of Sodium Nitrate for Interpretation of the Reflectance Spectrum of Pressed Pellets

Reflectance spectroscopy is notoriously confounding in that the measured spectral response is highly dependent upon the morphology of the sample. Fortunately, all such perturbations are neatly encoded by the complex refractive index of the sample. Herein, we seek to quantitatively model the measured infrared reflectance spectrum of a specularly flat pressed pellet sample of the birefringent compound, sodium nitrate. Single crystals of sodium nitrate were synthesized via a slow evaporation process and spectroscopically analyzed using polarization-dependent infrared single-angle reflectance spectroscopy. The anisotropic complex refractive index was measured from 7500 to 300 cm-1 (1.33 to 33.33 µm). The deduced anisotropic optical constants were found to be consistent with those previously reported. Once measured and validated, the optical constants were applied to model the pressed pellet reflectance spectrum. It was evident that an average of the anisotropic refractive indices was insufficient to account for the measured pellet reflectance. In order to account for contributions of all possible microcrystalline orientations within the pellet, the Python package PYELLI was used to calculate a basis set of orientation-dependent reflection spectra spanning the distinct ? and ? Euler rotations of the uniaxial crystal. When the population of orientations was allowed to vary freely in a spectral fit analysis, the fit-deduced orientations were tightly clustered along f = 45º, hinting at residual anisotropy in the pressed pellet sample. Conversely, an equally valid spectral fit (with marginally worse fit metric) was obtained when the population was constrained to an isotropic distribution of orientations. Subsequent non-zero cross-polarization reflectance measurements likewise suggested anisotropy in the pellet. However, both grazing incidence wide-angle x-ray scattering and scanning electron microscopy measurements revealed that the microcrystal orientations at the surface of the pressed pellet sample were isotropically distributed (and that the average crystallite size was larger than ?/10). Application of the measured complex refractive indices for modeling the reflectance spectrum of the pressed pellet, and rectification of these seemingly contradictory observations will be discussed.

Wilhelm, Michael J.↗

An Infrared Database of n/k Optical Constants for Calculating Aerosol Spectra for the PICARD Program

The objective of the PICARD Program is to develop fieldable sensing platforms for the rapid chemical identification of aerosol particles in plumes. Standoff detection involves interrogating the aerosol cloud from a distance using optical methods and probing the signal returned from direct backscattering from the aerosol particles or transmitted through the plume after reflection from a retroreflector or surface of opportunity (SOO). The identification of chemical species, however, in aerosols is complicated by their complex compositions and morphologies, chemical interferants, and non-uniform particle sizes. To advance standoff detection of aerosols, modelling the infrared transmittance, reflectance and scattering spectra of aerosolized liquid and solid chemical compounds is required, and then testing that model experimentally via laboratory and field experiments. To perform accurate modeling, the infrared optical constants (n/k), i.e., the complex refractive index, of the compounds of interest are required. Thus, PNNL was tasked to provide the optical constants for a set of analytes relevant to the PICARD program. This report describes the experimental techniques used to derive the optical constants of both liquid and solid compounds using established “gold-standard” protocols, how the experimental data are processed to produce the wavenumber dependent optical constant vectors, and how the data are used in the aerosol absorption spectra modeling.

complex refractive index↗

Comparing gas composition from fast pyrolysis of live foliage measured in bench-scale and fire-scale experiments

Background: Fire models have used pyrolysis data from oxidising and non-oxidising environments for flaming combustion. In wildland fires pyrolysis, flaming and smouldering combustion typically occur in an oxidising environment (the atmosphere). Aims: Using compositional data analysis methods, determine if the composition of pyrolysis gases measured in non-oxidising and ambient (oxidising) atmospheric conditions were similar. Methods: Permanent gases and tars were measured in a fuel-rich (non-oxidising) environment in a flat flame burner (FFB). Permanent and light hydrocarbon gases were measured for the same fuels heated by a fire flame in ambient atmospheric conditions (oxidising environment). Log-ratio balances of the measured gases common to both environments (CO, CO 2 , CH 4 , H 2 , C 6 H 6 O (phenol), and other gases) were examined by principal components analysis (PCA), canonical discriminant analysis (CDA) and permutational multivariate analysis of variance (PERMANOVA). Key results: Mean composition changed between the non-oxidising and ambient atmosphere samples. PCA showed that flat flame burner (FFB) samples were tightly clustered and distinct from the ambient atmosphere samples. CDA found that the difference between environments was defined by the CO-CO 2 log-ratio balance. PERMANOVA and pairwise comparisons found FFB samples differed from the ambient atmosphere samples which did not differ from each other. Conclusion: Relative composition of these pyrolysis gases differed between the oxidising and non-oxidising environments. This comparison was one of the first comparisons made between bench-scale and field scale pyrolysis measurements using compositional data analysis. Implications: These results indicate the need for more fundamental research on the early time-dependent pyrolysis of vegetation in the presence of oxygen.

54 ENVIRONMENTAL SCIENCES↗

Optical constants measurements of liquids for modeling aerosolized threats

Spectroscopic identification of aerosolized chemical threats is challenging due to the complex nature of the photon/particle interaction, as well as the diversity of possible particle sizes, morphologies, and compositions. Constructing a database of laboratory - measured transmittance spectra that covers each permutation is not practical. However, calculation of the spectra using the measured optical constants as a function of wavenumber, n(?) and k(?), for each of the liquids and/or solids composing the aerosol particles provides a viable alternative. These synthetic spectra (vis-à-vis laboratory-measured spectra) can be used to identify chemicals of interest and subtract out background interferents in field measurements. Using a well-established multiple pathlength approach, we measure the optical constants n/k for liquids that may be found as chemical species of interest or common background interferents aerosolized in plumes. These measurements are also used to generate several test case aerosol synthetic spectra.

Lockwood, Schuyler↗

Optimal spectral resolution for solids and liquids using FT and other infrared spectrometers: How much resolution do you really need?

In this study we investigate the possibility of using spectral resolutions for infrared measurements of solids and liquids that are not powers of two, e.g. are not at 1, 2, 4, 8, or 16 cm-1 resolution. In almost all reported literature of the last fifty years the resolution used to record for a Fourier transform infrared spectrum has been a power of two. This stems from the fact that 1) the Cooley-Tukey algorithm used to compute such a transform was constructed to use only powers of two and was also driven by 2) the fact that the computing horsepower required to compute the Fourier transform increases as N?log?_2 (N), where N is the number of points in the interferogram (spectrum). For typical spectra, however, the CPU time is no longer a consideration. Our study is based on both liquid and solid spectra, all of which were recorded at 2 cm-1 resolution. There were at total of 70 solids spectra representing 2,472 spectral peaks and 61 liquids spectra (1,765 spectral peaks), each peak being inspected for being singlet / multiplet in nature. Of the 1,765 liquid bands examined, only 27 had widths less than 5 cm-1. Of the 2,472 solid bands examined, only 39 peaks have widths less than 5 cm-1. For liquids, the mean peak width is 24.7 cm-1 but the median peak width is 13.7 cm-1, and, similarly, for solids, the mean peak width is 22.2 cm-1 but the median peak width is 11.2 cm-1. In both cases, solids and liquids, a skewed peak widths distribution was observed, the peak of the distribution representing narrower bands in the 7 to 9 cm-1 FWHM range but displaying a long tail to the very broad bands, with some displaying spectral widths of 100 cm-1 or more. Because one of the most important criteria for successful instrumental design in IR spectroscopy is the spectral resolution, the data were further analyzed showing that a value to resolve 95% of all bands is 5.7 cm-1 for liquids and 5.3 cm-1 for solids; such a resolution would capture the native linewidth (no instrumental broadening) of 95% of all the solids and liquid bands, respectively. Based on the present results we suggest that, when accounting only for intrinsic linewidths an optimized resolution of 6.0 cm-1 will capture 91% of all condensed-phase bands for IR detection of chemical, mineral, and biological materials.

Forland, Brenda M.↗

Deriving the Infrared Complex Refractive Indices of Organic Powders for Optical Modeling: Comparison of Methods

Identification of solids via infrared reflection spectroscopy requires a spectral library of all solids likely to be encountered. A confounding factor in populating such a spectral library is that the reflectance spectra of solids vary with their form, including particle size, film thickness, and substrate. To reduce the efforts of experimentally constructing such a library, an alternate strategy is to use the wavelength-dependent optical constants, n and k, of a solid to calculate a series of reflectance spectra corresponding to each scenario or morphology. Because most n/k measurements are best performed on mm-sized crystals, however, the challenge of determining the optical constants increases when a solid is only readily available as a powder, as is often the case. Some organic solids, such as caffeine, are both unavailable in large crystals and difficult to press into pellets. In this study, the infrared optical constants, or complex refractive indices, of caffeine were determined using three different methods: single-angle reflectance, infrared spectroscopic ellipsometry, and quantitative absorbance measurements of KBr pellets. The n and k values derived through each method were used to model the hyperspectral imaging reflectance spectrum of a caffeine film on a steel planchet. Over 1,110 – 870 cm-1, the single-angle reflectance-derived n and k had the best correlation with the experimental spectrum. These results suggest different organic solids may require different methods to determine the most accurate infrared complex refractive indices for synthetic spectral libraries.

FTIR, hyperspectral imaging, infrared, infrared (I↗

Optimal Spectral Resolution for Infrared Studies of Solids and Liquids

Due to a legacy originating in the limited capability of early computers, the spectroscopic resolution used in Fourier transform infrared spectroscopy and other systems has largely been implemented using only powers of two for more than 50 years. In this study, we investigate debunking the spectroscopic lore of, e.g., using only 2, 4, 8, or 16 cm −1 resolution and determine the optimal resolution in terms of both (i) a desired signal-to-noise ratio and (ii) efficient use of acquisition time. The study is facilitated by the availability of solids and liquids reference spectral data recorded at 2.0 cm −1 resolution and is based on an examination in the 4000–400 cm −1 range of 61 liquids and 70 solids spectra, with a total analysis of 4237 peaks, each of which was also examined for being singlet/multiplet in nature. Of the 1765 liquid bands examined, only 27 had widths <5 cm −1 . Of the 2472 solid bands examined, only 39 peaks have widths <5 cm −1 . For both the liquid and solid bands, a skewed distribution of peak widths was observed: For liquids, the mean peak width was 24.7 cm −1 but the median peak width was 13.7 cm −1 , and, similarly, for solids, the mean peak width was 22.2 cm −1 but the median peak width was 11.2 cm −1 . While recognizing other studies may differ in scope and limiting the analysis to only room temperature data, we have found that a resolution to resolve 95% of all bands is 5.7 cm −1 for liquids and 5.3 cm −1 for solids; such a resolution would capture the native linewidth (not accounting for instrumental broadening) for 95% of all the solids and liquid bands, respectively. After decades of measuring liquids and solids at 4, 8, or 16 cm −1 resolution, we suggest that, when accounting only for intrinsic linewidths, an optimized resolution of 6.0 cm −1 will capture 91% of all condensed-phase bands, i.e., broadening of only 9% of the narrowest of bands, but yielding a large gain in signal-to-noise with minimal loss of specificity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method to derive the infrared complex refractive indices n(λ) and k(λ) for organic solids from KBr pellet absorption measurements

Obtaining the complex refractive index vectors $n($$\tilde{v})$ and $k($$\tilde{v})$ allows calculation of the (infrared) reflectance spectrum that is obtained from a solid in any of its many morphological forms. Here, we report an adaptation to the KBr pellet technique using two gravimetric dilutions to derive quantitative $n($$\tilde{v})$/$k($$\tilde{v})$ for dozens of powders with greater repeatability. The optical constants of bisphenol A and sucrose are compared to those derived by other methods, particularly for powdered materials. The variability of the $k$ values for bisphenol A was examined by 10 individual measurements, showing an average coefficient of variation for $k$ peak heights of 5.6%. Though no established standards exist, the pellet-derived $k$ peak values of bisphenol A differ by 11% and 31% from their single-angle- and ellipsometry-derived values, respectively. These values provide an initial estimate of the precision and accuracy of complex refractive indices that can be derived using this method. Limitations and advantages of the method are discussed, the salient advantage being a more rapid method to derive $n$/$k$ for those species that do not readily form crystals or specular pellets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Controlling the Fluctuating Tip-Enhanced Raman Spectra of Chloramben on Silver Nanocubes

Tip-enhanced Raman (TER) scattering from molecules residing at plasmonic junctions can be used to detect, identify, and image single molecules. This is most evident for flat molecules interrogated under extreme conditions of temperatures and pressure. It is also the case for (bio)molecular systems that feature preferred orientations/conformations under ambient laboratory conditions. More complex molecules that can adopt multiple conformations and/or that feature different protonation and/or charge states give rise to complex TER spectra. Here we illustrate how the latter can be controlled in the case of chloramben molecules coated onto plasmonic silver nanocubes. We show that characteristic molecular Raman spectra cannot be obtained when tunneling plasmons are operative, i.e., when the tip is in direct contact with the chemically functionalized plasmonic nanoparticles. We rationalize these observations and propose an approach to less invasive, and hence, more analytical TER spectral imaging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preparation and Characterization Methods of Thin Layer Samples for Standoff Detection

Detection of analytes deposited on surfaces is crucial for many applications: Development of methods to prepare thin layers (e.g. ~5 to 100 µm) is important for both system design and field studies. In this work, solid and liquid analytes were deposited on painted and bare substrates including aluminum, glass, plastic, and concrete using an ExactaCoat ultrasonic spray coater. Laboratory hemispherical reflectance (HRF) spectra were collected for samples with different layer thicknesses so as to characterize both the composition and layer thickness. Preliminary results demonstrate that to prepare homogenous layers on surfaces, parameters such as substrate type, analyte solubility, vapor pressure, paint color, surface porosity, and surface roughness are all important. Liquid chemicals posed several issues during deposition: Diisopropyl methyl phosphonate evaporated from surfaces more quickly than the other chemicals and was thus not detected in the HRF experiments. Less volatile liquids, such as tributylphosphate, remained on the surface for the duration of the test, but a uniform layer thickness could not be obtained as the liquid pooled to one side when mounted at an angle. The deposition of solids (e.g., acetaminophen, caffeine and methylphosphonic acid) from volatile solvents such as chloroform also proved problematic due to streaking caused by rapid solvent evaporation. Solids deposited from ethanol, however, worked well on bare substrates. For most samples plotting the integrated infrared band strength vs. surface thicknesses showed a linear relationship, confirming that the surface loading can be controlled by programming the concentration and the number of passes on the ultrasonic sprayer.

Thin layer, deposition, infrared standoff, Hemisph↗

Using synthetic infrared spectra derived from n/k optical constants for standoff detection of chemical deposits

We report results from a recent field experiment to test the validity of using physics-based synthetic infrared spectra to serve as endmembers in a spectral database targeted at chemical deposits. Specifically, the optical constants n and k, (the real and imaginary part of the refractive index) were used to first model infrared reflectance spectra for different thicknesses of chemical layers (e.g. acetaminophen, methylphosphonic acid – MPA, etc.) on various conducting and insulating substrates such as aluminum, wood, and glass. In the experimental portion of the research, thin films of the solid and liquid analytes were deposited onto such substrates to form micron-thick layers of the analytes at different thicknesses: Standoff data from an imaging instrument were then recorded and analyzed to not only identify the different analytes, but also quantify the layer/deposit thickness. To gauge success, the detection results using the synthetic data were compared to the results from hemispherical reflectance (HRF) spectra that were collected for the same sample planchets measured in the field via standoff methods. Preliminary results indicate good agreement between the synthetic reference data as compared to the lab-measured HRF data in terms of their ability to quantitatively reduce longwave infrared data. Specifically, modeled IR spectra for acetaminophen on an aluminum planchet at various thicknesses (1, 2, 5, 10, 15, and 20 µm) were synthesized and compared with standoff field reflectance data as well as HRF laboratory reflectance spectra for two samples: a 5.2 µm- and 12.8 µm-thick layer of acetaminophen on aluminum. Using a first-order approximation, analysis of the field data estimates the thicknesses of the samples to be 2 and 10 µm for the two samples, respectively, while the HRF laboratory data yields thickness estimates of between 5-10 µm and 10 µm, respectively. Both yield reasonable estimates, with the uncertainty most likely due to factors yet to be accounted for in the synthetic spectra such as light scattering.

complex index of refraction, optical constants, hy↗

Comparison of methods to derive infrared optical constants for organic materials for optical modeling

Reflectance spectroscopy, especially at infrared wavelengths, is often used for contact, standoff, and remote sensing of solid materials. The reflectance spectra of solids, however, are complex, relying on many factors, even for the same material. Such phenomena can be modeled if the optical constants as a function of wavelength or wavenumber, n(?) and k(?), are known. Methods to measure the optical constants of solids, however, are challenging, particularly for powdered materials. For powdered materials, a pressed pellet of the neat material is often used when a crystalline specimen is not available. In this work, three techniques, including ellipsometry, single-angle reflectance and KBr transmission spectroscopy, are applied to an organic material, acetaminophen, for comparison, and the effects on the modeled spectra are shown.

ellipsometry, infrared (IR) spectroscopy, FTIR, hy↗

Disentangling the confounding spectroscopy of C 1 molecules: Without symmetry as a guide, everything is allowed

The spectra of C 1 molecules are confounding in that each of the fundamental vibrational modes transform as the same irreducible representation (A) and hence each band consists of a seemingly random distribution of a-, b-, and c-type transitions. This is in contrast to higher symmetry molecules for which band types are readily deduced by simple symmetry rules. Herein, we present a method to simulate the convoluted rotational contours in the gas-phase spectra of C 1 molecules by combining existing ab initio calculations with Colin Western’s PGOPHER rotational contour program. Specifically, ab initio calculations in the NWC HEM suite of programs were employed to predict the components of the dipole moment derivatives along the principal axes of the moments of inertia. This information was then input into PGOPHER to model the fundamental band contours as a sum of a-, b-, and c-type transitions. This method was applied to simulate the rotational contour spectra of a series of representative C 1 molecules which were then compared against both ab initio stick spectra and experimentally measured broadband IR spectra from the Pacific Northwest National Laboratory infrared gas-phase database. In addition to providing further insight beyond what is revealed in a typical stick spectrum, the simulated contours showed good agreement with the measured spectra.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Interactive Spectral Analysis Tool for Chemical Identification and Quantification of Gas-Phase Species in Complex Spectra

A spectral analysis tool has been developed to interactively identify and quantify individual gas-phase species from complex infrared absorbance spectra obtained from laboratory or field data. The SpecQuant program has an intuitive graphical interface that accommodates both reference and experimental data with varying resolution and instrumental lineshape, as well as algorithms to readily align the wavenumber axis of a sample spectrum with the raster of a reference spectrum. Using a classical least squares model in conjunction with reference spectra such as those from the Pacific Northwest National Laboratory (PNNL) gas-phase infrared database or simulated spectra derived from the HITRAN line-by-line database, the mixing ratio of each identified species is determined along with its associated estimation error. After correcting the wavelength and intensity of the field data, SpecQuant displays the calculated mixing ratio versus the experimental data for each analyte along with the residual spectrum with any or all analyte fits subtracted for visual inspection of the fit and residuals. The software performance for multianalyte quantification was demonstrated using moderate resolution (0.5 cm –1 ) infrared spectra that were collected during the time-resolved infrared photolysis of methyl iodide.

Thompson, Christopher J.↗