Electron scattering distributions as a probe of adsorbate orientation - CO and N2

The differential cross section for elastic electron scattering by adsorbed CO and N2 is calculated. The dependence of this cross section on the azimuthal angle of detection depends on the molecular orientation and can be used to differentiate between a molecule lying flat on the surface, a tilted molecule, and an upright one. For molecules lying flat on the surface, the orientation of the molecular axis and of the C and O atoms with respect to the plane of incidence of the electron can be determined.

Nagano, S.

Lightweight, Low-Loss dc Transducer

Direct current is measured by lightweight, magnetically coupled transducer that weighs only 4 grams, without actually being wired into circuit under test. Miniature dc transducer has five windings: 2 for ac excitation inputs, 2 for dc control inputs, and 1 for feedback. Wire gages are selected for minimum size and weight. Size and number of turns of dc windings are selected according to dc current range to be measured.

Nagano, S.

Low current linearization of magnetic amplifier for dc transducer

A magnetic amplifier having two saturable reactor cores with a separate excitation winding on each connected in series opposition, a common control winding, and a common output winding, is adapted for use as a low level signal transducer. The separate excitation windings are excited in push-pull mode through a center tapped transformer, and at least one diode is included in series with a load resistor connected to the output winding. A resistor in series with the output winding and load resistor is connected between the center tap of the excitation transformer and the connection between the two excitation windings of the saturable cores. This series resistor provides a return current path for the output winding and allows the excitation windings of the saturable cores to operate as primary windings of transformers.

Nagano, S.

Base drive for paralleled inverter systems

In a paralleled inverter system, a positive feedback current derived from the total current from all of the modules of the inverter system is applied to the base drive of each of the power transistors of all modules, thereby to provide all modules protection against open or short circuit faults occurring in any of the modules, and force equal current sharing among the modules during turn on of the power transistors.

Nagano, S.

Redundant operation of counter modules

A technique for the redundant operation of counter modules is described. Redundant operation is maintained by detecting the zero state of each counter and clearing the other to that state, thus periodically resynchronizing the counters, and obtaining an output from both counters through AC coupled diode-OR gates. Redundant operation of counter flip flops is maintained in a similar manner, and synchronous operation of redundant squarewave clock generators of the feedback type is effected by connecting together the feedback inputs of the squarewave generators through a coupling resistor, and obtaining an output from both generators through AC coupled diode-OR gates.

Nagano, S.

Reliable inverter systems

Base driver with common-load-current feedback protects paralleled inverter systems from open or short circuits. Circuit eliminates total system oscillation that can occur in conventional inverters because of open circuit in primary transformer winding. Common feedback signal produced by functioning modules forces operating frequency of failed module to coincide with clock drive so module resumes normal operating frequency in spite of open circuit.

Nagano, S.

Module failure isolation circuit for paralleled inverters

A module failure isolation circuit is described which senses and averages the collector current of each paralled inverter power transistor and compares the collector current of each power transistor the average collector current of all power transistors to determine when the sensed collector current of a power transistor in any one inverter falls below a predetermined ratio of the average collector current. The module associated with any transistor that fails to maintain a current level above the predetermined radio of the average collector current is then shut off. A separate circuit detects when there is no load, or a light load, to inhibit operation of the isolation circuit during no load or light load conditions.

Nagano, S.

Circuit for automatic load sharing in parallel converter modules

A nondissipative circuit for automatic load sharing in parallel converter modules having push-pull power transistors is presented. Each transistor has a separate current-sensing transformer and an impedance-adjusting transformer in series with its collector. The impedance-adjusting transformer functions as a current-controlled variable impedance that is responsive to the difference between the peak collector current of the transistor and the average peak current of all collector currents of power transistors in all modules, thereby to control the collector currents of all power transistors with reference to the average peak collector current.

Nagano, S.

Overload protection system

Overload protection circuit utilizes one circuit for suspending inverter action when load abnormality is detected and second circuit to monitor clearance of abnormality. Device wastes no power during normal operating conditions and responds instantaneously when abnormality is cleared.

Nagano, S.

Automatic load sharing in inverter modules

Active feedback loads transistor equally with little power loss. Circuit is suitable for balancing modular inverters in spacecraft, computer power supplies, solar-electric power generators, and electric vehicles. Current-balancing circuit senses differences between collector current for power transistor and average value of load currents for all power transistors. Principle is effective not only in fixed duty-cycle inverters but also in converters operating at variable duty cycles.

Nagano, S.

Synchronous transfer circuits for redundant systems

Circuit arrangements for flip-flops, counters, and clock drivers in redundant systems ensure that control is synchronously transferred to surviving components when failure occurs. In addition to original application to spacecraft systems, redundant circuits have terrestrial uses in power generators, solar-energy converters, computers, vehicle controllers, and other systems demanding high reliability.

Nagano, S.

Overload protection system for power inverter

An overload protection system for a power inverter utilized a first circuit for monitoring current to the load from the power inverter to detect an overload and a control circuit to shut off the power inverter, when an overload condition was detected. At the same time, a monitoring current inverter was turned on to deliver current to the load at a very low power level. A second circuit monitored current to the load, from the monitoring current inverter, to hold the power inverter off through the control circuit, until the overload condition was cleared so that the control circuit may be deactivated in order for the power inverter to be restored after the monitoring current inverter is turned off completely.