Search NASA⌕ Search

Engineering topics

Nakagawa, I.

Publications and source records attributed to Nakagawa, I..

Precision measurement of the neutral pion lifetime

The explicit breaking of the axial symmetry by quantum fluctuations gives rise to the so-called axial anomaly. This phenomenon is solely responsible for the decay of the neutral pion π0 into two photons (γγ), leading to its unusually short lifetime. Here, we precisely measured the decay width Γ of the π 0 → γγ process. The differential cross sections for π0 photoproduction at forward angles were measured on two targets, carbon-12 and silicon-28, yielding Γ(π 0 → γγ)=7.798±0.056(stat.)±0.109(syst.) eV, where stat. denotes the statistical uncertainty and syst. the systematic uncertainty. We combined the results of this and an earlier experiment to generate a weighted average of Γ(π 0 → γγ)=7.802±0.052(stat.)±0.105(syst.) eV. Our final result has a total uncertainty of 1.50% and confirms the prediction based on the chiral anomaly in quantum chromodynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High precision measurement of Compton scattering in the 5 GeV region

The cross section of atomic electron Compton scattering $\gamma + e \rightarrow \gamma^\prime + e^\prime $ was measured in the 4.40--5.475 GeV photon beam energy region by the {\em PrimEx} collaboration at Jefferson Lab with an accuracy of 2\% and less. The results are consistent with theoretical predictions that include next-to-leading order radiative corrections. The measurements provide the first high precision test of this elementary QED process at beam energies greater than 0.1 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High precision photon flux determination for photon tagging experiments

The Jefferson Laboratory PrimEx Collaboration has developed and implemented a method to control the tagged photon flux in photoproduction experiments at the 1% level over the photon energy range from 4.9 to 5.5 GeV. This method has been successfully implemented in a high precision measurement of the neutral pion lifetime. Here, we outline the experimental equipment and the analysis techniques used to accomplish this. These include the use of a total absorption counter for absolute flux calibration, a pair spectrometer for online relative flux monitoring, and a new method for post-bremsstrahlung electron counting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Measurement of the {pi}{sup 0} Radiative Decay Width

High precision measurements of the differential cross sections for {pi}{sup 0} photoproduction at forward angles for two nuclei, {sup 12}C and {sup 208}Pb, have been performed for incident photon energies of 4.9-5.5 GeV to extract the {pi}{sup 0}{yields}{gamma}{gamma} decay width. The experiment was done at Jefferson Lab using the Hall B photon tagger and a high-resolution multichannel calorimeter. The {pi}{sup 0}{yields}{gamma}{gamma} decay width was extracted by fitting the measured cross sections using recently updated theoretical models for the process. The resulting value for the decay width is {Gamma}({pi}{sup 0}{yields}{gamma}{gamma})=7.82{+-}0.14(stat){+-}0.17(syst) eV. With the 2.8% total uncertainty, this result is a factor of 2.5 more precise than the current Particle Data Group average of this fundamental quantity, and it is consistent with current theoretical predictions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Run-08 pC polarization analysis

In this note we will discuss the analysis of RHIC run 08 pC data that were collected during February 14 - March 10, 2008. An analysis method that is similar to Run 05 and Run 06 was adopted for Run 08 analysis (except few minor changes, which are described below). A detailed analysis note and a NIM article that describe the pC analysis procedure (for run 05 and run 06) can be found elsewhere [1]. In brief, the analysis consists of calibrating the detectors, determining energy corrections (“dead layers”), determining good runs and extracting the polarization from data. Next few sections describe these steps more in detail.

43 PARTICLE ACCELERATORS↗

Application of precise altimetry to the study of precise leveling of the sea surface, the Earth's gravity field, and the rotation of the Earth

Our program includes five research items: (1) determination of a precision geoid and gravity anomaly field; (2) precise leveling and detection of tidal changes of the sea surface and study of the role of the tide in the global energy exchange; (3) oceanic effect on the Earth's rotation and polar motion; (4) geological and geophysical interpretation of the altimetry gravity field; and (5) evaluation of the effectiveness of local tracking of TOPEX/POSEIDON by use of a laser tracker.

Segawa, J.↗