Search NASA⌕ Search

Engineering topics

Nakamura, K

Publications and source records attributed to Nakamura, K.

At least 19 records

Greater than 1000-fold Gain in a Free-Electron Laser Driven by a Laser-Plasma Accelerator with High Reliability

Compact free-electron lasers (FELs) based on plasma-based accelerators have been envisioned for many years. While recent milestone experiments have demonstrated feasibility, further progress is needed to establish laser-plasma-accelerator-driven FELs as reliable light sources. Demonstrating both full FEL saturation and reliable operation commensurate with conventional FEL facilities is critical. We report progress on both of these fronts. FEL gain exceeding 1000 at a wavelength of 420 nm in the self-amplified spontaneous emission regime has been measured. Lower and upper bounds for the characteristic exponential gain length were measured at 16.7-22.5 cm. Additionally, reliability of the laser-plasma-accelerator-driven FEL, defined here as the percentage of shots displaying FEL gain, reached an unprecedented level of greater than 90% over the course of an hour while operating at 1 Hz repetition rate.

Barber, S K↗

Low-energy astrophysics with KamLAND

We present two results of a search for MeV-scale neutrino and anti-neutrino events correlated with gravitational wave events/candidates and large solar flares with KamLAND. The KamLAND detector is a large-volume neutrino detector using liquid scintillator, which is located at 1 km underground under the top of Mt. Ikenoyama in Kamioka, Japan. KamLAND has multiple reaction channels to detect neutrinos. Electron antineutrino can be detected via inverse-beta decay with 1.8 MeV neutrino energy threshold. All flavors of neutrinos can be detected via neutrino-electron scattering without neutrino energy threshold. KamLAND has continued the neutrino observation since 2002 March. We use the data set of 60 gravitational waves provided by the LIGO/Virgo collaboration during their second and third observing runs and search for coincident electron antineutrino events in KamLAND. We find no significant coincident signals within a ±500 s timing window from each gravitational wave and present 90% C.L. upper limits on the electron antineutrino fluence between 10 8 –10 13 cm -2 for neutrino energies of 1.8–111 MeV. For a solar-flare neutrino search at KamLAND, we determine the timing window using the solar X-ray data set provided by the GOES satellite series from 2002 to 2019 and search for the excess of coincident event rate on the all-flavor neutrinos. We find no significant event rate excess in the flare time windows and get 90% C.L. upper limits on the fluence of neutrinos of all flavors (electron anti-neutrinos) between 10 10 –10 13 cm -2 (10 8 –10 13 cm -2 ) for neutrino energies in the energy range of 0.4–35 MeV.

79 ASTRONOMY AND ASTROPHYSICS↗

Feasibility study of a compact heavy ion source for investigation of laboratory magnetospheric plasma

We are developing a laser ion source to provide a high brightness multi-charged heavy ion beam as a part of the heavy ion beam probe system, which will be used to diagnose plasma potential in the Ring Trap 1 device at the University of Tokyo. As a probe beam, Nb2+ was selected, and a detailed laser irradiation condition was explored. It was found that the laser power density of 1.2 × 109 W/cm2 gives the maximum particle number of Nb2+ per laser energy from a niobium foil target. Essential ablation plasma parameters to design the laser ion source were also obtained. The expected beam current was more than 12 mA/cm2, with a pulse width of 3.1 µs at 200 mm away from the target.

Nakamura, K. (ORCID:0000000176882589)↗

Petawatt Laser Guiding and Electron Beam Acceleration to 8 GeV in a Laser-Heated Capillary Discharge Waveguide.

Guiding of relativistically intense laser pulses with peak power of 0.85 PW over 15 diffraction lengths was demonstrated by increasing the focusing strength of a capillary discharge waveguide using laser inverse bremsstrahlung heating. This allowed for the production of electron beams with quasimonoenergetic peaks up to 7.8 GeV, double the energy that was previously demonstrated. Charge was 5 pC at 7.8 GeV and up to 62 pC in 6 GeV peaks, and typical beam divergence was 0.2 mrad.

Gonsalves, AJ↗

CeLAND: search for a 4th light neutrino state with a 3 PBq 144 Ce- 144 Pr electron antineutrino generator in KamLAND

The reactor neutrino and gallium anomalies can be tested with a 3-4 PBq (75-100 kCi scale) 144 Ce- 144 Pr antineutrino beta-source deployed at the center or next to a large low-background liquid scintillator detector. The antineutrino generator will be produced by the Russian reprocessing plant PA Mayak as early as 2014, transported to Japan, and deployed in the Kamioka Liquid Scintillator Anti-Neutrino Detector (KamLAND) as early as 2015. KamLAND's 13 m diameter target volume provides a suitable environment to measure the energy and position dependence of the detected neutrino flux. A characteristic oscillation pattern would be visible for a baseline of about 10 m or less, providing a very clean signal of neutrino disappearance into a yet-unknown, sterile neutrino state. This will provide a comprehensive test of the electron dissaperance neutrino anomalies and could lead to the discovery of a 4th neutrino state for Δm$2\atop{new}$ ≳ 0.1 eV 2 and sin 2 (2θ new ) > 0.05.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-D-BRA-04: Computerized Framework for Marker-Less Localization of Anatomical Feature Points in Range Images Based On Differential Geometry Features for Image-Guided Radiation Therapy

Purpose: To propose a computerized framework for localization of anatomical feature points on the patient surface in infrared-ray based range images by using differential geometry (curvature) features. Methods: The general concept was to reconstruct the patient surface by using a mathematical modeling technique for the computation of differential geometry features that characterize the local shapes of the patient surfaces. A region of interest (ROI) was firstly extracted based on a template matching technique applied on amplitude (grayscale) images. The extracted ROI was preprocessed for reducing temporal and spatial noises by using Kalman and bilateral filters, respectively. Next, a smooth patient surface was reconstructed by using a non-uniform rational basis spline (NURBS) model. Finally, differential geometry features, i.e. the shape index and curvedness features were computed for localizing the anatomical feature points. The proposed framework was trained for optimizing shape index and curvedness thresholds and tested on range images of an anthropomorphic head phantom. The range images were acquired by an infrared ray-based time-of-flight (TOF) camera. The localization accuracy was evaluated by measuring the mean of minimum Euclidean distances (MMED) between reference (ground truth) points and the feature points localized by the proposed framework. The evaluation was performed for points localized on convex regions (e.g. apex of nose) and concave regions (e.g. nasofacial sulcus). Results: The proposed framework has localized anatomical feature points on convex and concave anatomical landmarks with MMEDs of 1.91±0.50 mm and 3.70±0.92 mm, respectively. A statistically significant difference was obtained between the feature points on the convex and concave regions (P<0.001). Conclusion: Our study has shown the feasibility of differential geometry features for localization of anatomical feature points on the patient surface in range images. The proposed framework might be useful for tasks involving feature-based image registration in range-image guided radiation therapy.

60 APPLIED LIFE SCIENCES↗

WE-AB-207B-03: A Computational Methodology for Determination of CTV-To-PTV Margins with Inter Fractional Shape Variations Based On a Statistical Point Distribution Model for Prostate Cancer Radiation Therapy

Purpose: Our assumption was that interfractional shape variations of target volumes could not be negligible for determination of clinical target volume (CTV)-to-planning target volume (PTV) margins. The aim of this study was to investigate this assumption as a simulation study by developing a computational framework of CTV-to-PTV margins with taking the interfractional shape variations into account based on point distribution model (PDM) Methods: The systematic and random errors for interfractional shape variations and translations of target volumes were evaluated for four types of CTV regions (only a prostate, a prostate plus proximal 1-cm seminal vesicles, a prostate plus proximal 2-cm seminal vesicles, and a prostate plus whole seminal vesicles). The CTV regions were delineated depending on prostate cancer risk groups on planning computed tomography (CT) and cone beam CT (CBCT) images of 73 fractions of 10 patients. The random and systematic errors for shape variations of CTV regions were derived from PDMs of CTV surfaces for all fractions of each patient. Systematic errors of shape variations of CTV regions were derived by comparing PDMs between planning CTV surfaces and average CTV surfaces. Finally, anisotropic CTV-to-PTV margins with shape variations in 6 directions (anterior, posterior, superior, inferior, right, and left) were computed by using a van Herk margin formula. Results: Differences between CTV-to-PTV margins with and without shape variations ranged from 0.7 to 1.7 mm in anterior direction, 1.0 to 2.8 mm in posterior direction, 0.8 to 2.8 mm in superior direction, 0.6 to 1.6 mm in inferior direction, 1.4 to 4.4 mm in right direction, and 1.3 to 5.2 mm in left direction. Conclusion: More than 1.0 mm additional margins were needed at least in 3 directions to guarantee CTV coverage due to shape variations. Therefore, shape variations should be taken into account for the determination of CTV-to-PTV margins.

60 APPLIED LIFE SCIENCES↗

SU-E-J-177: A Computational Approach for Determination of Anisotropic PTV Margins Based On Statistical Shape Analysis for Prostate Cancer Radiotherapy

Purpose: Our aim of this study was to propose a computational approach for determination of anisotropic planning target volume (PTV) margins based on statistical shape analysis with taking into account time variations of clinical target volume (CTV) shapes for the prostate cancer radiation treatment planning (RTP). Methods: Systematic and random setup errors were measured using orthogonal projection and cone beam computed tomography (CBCT) images for data of 20 patients, who underwent the intensity modulated radiation therapy for prostate cancer. The low-risk, intermediate-risk, and high-risk CTVs were defined as only a prostate, a prostate plus proximal 1-cm seminal vesicles, and a prostate plus proximal 2-cm seminal vesicles, respectively. All CTV regions were registered with a reference CTV region with a median volume to remove the effect of the setup errors, and converted to a point distribution models. The systematic and random errors for translations of CTV regions were automatically evaluated by analyzing the movements of centroids of CTV regions. The random and systematic errors for shape variations of CTV regions were obtained from covariance matrices based on point distributions for the CTV contours on CBCT images of 72 fractions of 10 patients. Anisotropic PTV margins for 6 directions (right, left, anterior, posterior, superior and inferior) were derived by using Yoda’s PTV margin model. Results: PTV margins with and without shape variations were 5.75 to 8.03 mm and 5.23 to 7.67 mm for low-risk group, 5.87 to 8.33 mm and 5.23 to 7.67 mm for intermediate-risk group, and 5.88 to 8.25 mm and 5.29 to 7.82 mm for highrisk group, respectively. Conclusion: The proposed computational approach could be feasible for determination of the anisotropic PTV margins with taking into account CTV shape variations for the RTP.

60 APPLIED LIFE SCIENCES↗

WE-AB-303-07: Computational Monitoring Framework of Four-Dimensional Dose Distributions During Treatment Time Based On a 2D/3D Registration with Adaptive Transformation Parameters in Lung Stereotactic Body Radiotherapy

Purpose: The aim of this study was to develop a computational framework for monitoring four-dimensional (4D) dose distributions during treatment time based on a 2D/3D registration with adaptive transformation parameters (ATPs) in lung stereotactic body radiotherapy (SBRT). Methods: The 4D dose distributions during the SBRT were calculated by applying a pencil beam convolution (PBC) algorithm to simulated 4D-computed tomography (CT) images during treatment time (hereinafter referred to as “treatment” 4D-CT images). The “treatment” 4D-CT images were derived by deforming 3D planning CT images by using transformation parameters so that 2D planning portal dose images (PDIs) can resemble 2D dynamic clinical PDIs in each frame, which were derived from electronic portal imaging device (EPID) images. The transformation parameters were optimized by the Levenberg- Marquardt (LM) algorithm. The optimized transformation parameters in a certain frame were adaptively employed as initial transformation parameters for optimization of the parameters in the consecutive frame. Gamma pass rates (3mm/3%) between dynamic clinical PDIs and dynamic “treatment” PDIs derived from the “treatment” 4D-CT images were measured for comparing the proposed frameworks without and with the ATPs. These proposed frameworks were applied to the EPID dynamic images (40 frames) of two patients with lung cancer, who underwent the SBRT. Results: Gamma pass rates without and with the ATPs were 83.01±4.42% and 89.31±3.18% on average, respectively (p<0.05). Moreover, percentage errors between prescribed doses and estimated doses at an isocenter by the proposed frameworks without and with the ATPs were 10.67±5.66% and 6.34±0.47% on average, respectively (p<0.05). Conclusion: The proposed framework with ATPs could be useful to ensure the quality of the SBRT by monitoring 4D dose distributions during treatment time.

60 APPLIED LIFE SCIENCES↗

Beam transport and monitoring for laser plasma accelerators

The controlled transport and imaging of relativistic electron beams from laser plasma accelerators (LPAs) are critical for their diagnostics and applications. Here we present the design and progress in the implementation of the transport and monitoring system for an undulator based electron beam diagnostic. Miniature permanent-magnet quadrupoles (PMQs) are employed to realize controlled transport of the LPA electron beams, and cavity based electron beam position monitors for non-invasive beam position detection. Also presented is PMQ calibration by using LPA electron beams with broadband energy spectrum. The results show promising performance for both transporting and monitoring. With the proper transport system, XUV-photon spectra from THUNDER will provide the momentum distribution of the electron beam with the resolution above what can be achieved by the magnetic spectrometer currently used in the LOASIS facility.

43 PARTICLE ACCELERATORS↗

Long-range persistence of femtosecond modulations on laser-plasma-accelerated electron beams

Laser plasma accelerators have produced femtosecond electron bunches with a relative energy spread ranging from 100% to a few percent. Simulations indicate that the measured energy spread can be dominated by a correlated spread, with the slice spread significantly lower. Measurements of coherent optical transition radiation are presented for broad-energy-spread beams with laser-induced density and momentum modulations. The long-range (meter-scale) observation of coherent optical transition radiation indicates that the slice energy spread is below the percent level to preserve the modulations.

43 PARTICLE ACCELERATORS↗

Successful Balloon-Occluded Retrograde Transvenous Obliteration for Gastric Varix Mainly Draining into the Pericardiophrenic Vein

Two cases of gastric varices were treated by balloon-occluded retrograde transvenous obliteration via the pericardiophrenic vein at our hospital, and both were successful. One case developed left hydrothorax. Gastric varices did not bled and esophageal varices were not aggravated in both cases for 24-30 months thereafter. These outcomes indicate the feasibility of balloon-occluded retrograde transvenous obliteration via the pericardiophrenic vein.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SEARCH FOR EXTRATERRESTRIAL ANTINEUTRINO SOURCES WITH THE KamLAND DETECTOR

We present the results of a search for extraterrestrial electron antineutrinos ({nu}-bar{sub e}'s) in the energy range 8.3 MeV < E{sub {nu}}-bar{sub e} < 31.8 MeV using the KamLAND detector. In an exposure of 4.53 kton-year, we identify 25 candidate events. All of the candidate events can be attributed to background, most importantly neutral current atmospheric neutrino interactions, setting an upper limit on the probability of {sup 8}B solar {nu}{sub e}'s converting into {nu}-bar{sub e}'s at 5.3 Multiplication-Sign 10{sup -5} (90% CL), if we assume an undistorted {nu}-bar{sub e} shape. This limit corresponds to a solar {nu}-bar{sub e} flux of 93 cm{sup -2} s{sup -1} or an event rate of 1.6 events (kton - year){sup -1} above the energy threshold (E{sub {nu}}-bar{sub e}>=8.3 MeV). The present data also allows us to set more stringent limits on the diffuse supernova neutrino flux and on the annihilation rates for light dark matter particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Novel Au-TiC Catalysts for CO Oxidation and Desulfurization Processes

Recent articles dealing with the physical and chemical properties of novel Au-TiC catalysts are reviewed. High-resolution photoemission, scanning tunneling microscopy and first-principles periodic density-functional calculations were used to study the deposition of gold on a TiC(0 0 1) surface. Gold grows forming two-dimensional (very low coverage) and three-dimensional (medium and large coverage) islands on the carbide substrate. A positive shift in the binding energy of the C 1s core level is observed after the deposition of Au on TiC(0 0 1). The results of the density-functional calculations corroborate the formation of Au-C bonds. In general, the bond between Au and the TiC(0 0 1) surface exhibits very little ionic character, but there is a substantial polarization of electrons around Au that facilitates bonding of the adatoms with electron-acceptor molecules (CO, O{sub 2}, C{sub 2}H{sub 4}, SO{sub 2}, thiophene, etc.). Experimental measurements indicate that Au/TiC(0 0 1) is a very good catalysts for the oxidation of CO, the destruction of SO{sub 2} and the hydrodesulfurization of thiophene. At temperatures below 200 K, Au/TiC(0 0 1) is able to perform the 2CO + O{sub 2} {yields} 2CO{sub 2} reaction and the full decomposition of SO{sub 2}. Furthermore, in spite of the very poor hydrodesulfurization performance of TiC(0 0 1) or Au(1 1 1), a Au/TiC(0 0 1) surface displays a hydrodesulfurization activity higher than that of conventional Ni/MoS{sub x} catalysts. Metal carbides are excellent supports for enhancing the chemical reactivity of gold. The Au/TiC system is more chemically active than systems generated by depositing Au nanoparticles on oxide surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electron Cyclotron / Bernstein Wave Heating and Current Drive Experiments using Phased-array Antenna in QUEST

The phased-array antenna system for Electron Cyclotron/Bernstein Wave Heating and Current Drive experiments has been developed in the QUEST. The antenna was designed to excite a pure O-mode wave in the oblique injection for the O-X-B mode conversion experiments, and its good performances were confirmed at a low power level. The plasma current (<{approx}15 kA) with an aspect ratio of 1.5 was started up and sustained by only RF injection in the low-density operations. The long pulse discharge of 10 kA was also attained for 37 s. The new density window to sustain the plasma current was observed in the high-density plasmas. The single-null divertor configuration with the high plasma current (<{approx}25 kA) was attained in the 17 s plasma sustainment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗