Netlander Positioning with the Mars Infrastructure Constellation and its Impact on Martian Geodesy
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Nandi, S..
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The radio signal from the Galileo prove to the orbiter experienced attenuation due to ammonia in Jupiter's atmosphere during the probe descent.
In July of 1995 the Airborne Emission Spectrometer was deployed to Nashville, Tennessee to participate in the 1995 Ozone Study Intensive Campaign of the Southern Oxidants Study. AES is a high resolution mid-infrared interferometer that measures the spectrum of upwelling radiation in the 650-4250 cm-1 range.
Explore the source record for details and available documents.
Ongoing Study to understand ground level ozone production and transport in the southeastern U.S.
Current methods of angular spacecraft positioning using station differenced range data require an additional observation of an extragalactic radio source (quasar) to estimate the timing offset between the reference clocks at the two Deep Space Stations. The quasar observation is also used to reduce the effects of instrumental and media delays on the radio metric observable by forming a difference with the spacecraft observation (delta differential one-way range, delta DOR). An experiment has been completed using data from the Global Positioning System satellites to estimate the station clock offset, eliminating the need for the quasar observation. The requirements for direct measurement of the instrumental delays that must be made in the absence of a quasar observation are assessed. Finally, the results of the 'quasar-free' differential one-way range, or DOR, measurements of the Mars Observer spacecraft are compared with those of simultaneous conventional delta DOR measurements.
A Global Positioning System (GPS) flight receiver provides a means to precisely determine orbits for satellites in low to moderate altitude orbits. Above a 5000-km altitude, however, relatively few GPS satellites are visible. New approaches to orbit determination for satellites at higher altitudes could reduce DSN antenna time needed to provide navigation and orbit determination support to future missions. Modification of GPS ground receivers enables a beacon from the orbiter to be tracked simultaneously with GPS data. The orbit accuracy expected from this GPS-like tracking (GLT) technique is expected to be in the range of a few meters or better for altitudes up to 100,000 km with a global ground network. For geosynchronous satellites, however, there are unique challenges due to geometrical limitations and to the lack of strong dynamical signature in tracking data. We examine two approaches for tracking the Tracking and Data Relay Satellite System (TDRSS) geostationary orbiters. One uses GLT with a global network; the other relies on a small 'connected element' ground network with a distributed clock for short-baseline differential carrier phase (SB Delta Phi). We describe an experiment planned for late 1993, which will combine aspects of both GLT and SB Delta Phi, to demonstrate a new approach for tracking the Tracking and Data Relay Satellites (TDRSs) that offers a number of operationally convenient and attractive features. The TDRS demonstration will be in effect a proof-of-concept experiment for a new approach to tracking spacecraft which could be applied more generally to deep-space as well as near-Earth regimes.
The Tracking and Data Relay Satellite System (TDRSS) was successfully used to track the Galileo spacecraft on December 8, 1992, during the Galileo Earth-2 Flyby. This flyby enabled Galileo to obtain a gravity-assisted energy increase as part of the Venus-Earth-Earth trajectory en route to the planet Jupiter.
The tracking and Data Relay Satellite System (TDRS) was successfully used to track the Galielo spacecraft on December 8, 1992, during the Galielo Earth-2 flyby. This flyby enabled Galielo to obtaina gravity assited energy increase as part of the Venus-Earth-Earth trajectory en route to the planet Jupiter.
A new radio metric positioning technique has demonstrated improved orbit determination accuracy for the Magellan and Pioneer Venus Orbiter orbiters. The new technique, known as Same-Beam Interferometry (SBI), is applicable to the positioning of multiple planetary rovers, landers, and orbiters which may simultaneously be observed in the same beamwidth of Earth-based radio antennas. Measurements of carrier phase are differenced between spacecraft and between receiving stations to determine the plane-of-sky components of the separation vector(s) between the spacecraft. The SBI measurements complement the information contained in line-of-sight Doppler measurements, leading to improved orbit determination accuracy. Orbit determination solutions have been obtained for a number of 48-hour data arcs using combinations of Doppler, differenced-Doppler, and SBI data acquired in the spring of 1991. Orbit determination accuracy is assessed by comparing orbit solutions from adjacent data arcs. The orbit solution differences are shown to agree with expected orbit determination uncertainties. The results from this demonstration show that the orbit determination accuracy for Magellan obtained by using Doppler plus SBI data is better than the accuracy achieved using Doppler plus differenced-Doppler by a factor of four and better than the accuracy achieved using only Doppler by a factor of eighteen. The orbit determination accuracy for Pioneer Venus Orbiter using Doppler plus SBI data is better than the accuracy using only Doppler data by 30 percent.
The radio metric tracking technique known as Same-Beam Interferometry has been shown to improve orbit determination accuracy for the Magellan and Pioneer 12 Orbiter.
This paper discusses a covariance study on the feasibility of using station-differenced carrier phase on short baselines to track the TDRSS satellites. Orbit accuracies for the TDRSS using station-differenced carrier phase data and range data collected from White Sands, NM are given for various configurations of ground stations and range data precision. A one-sigma-position position accuracy of 25 meters can be achieved using two orthogonal baselines of 100 km for the station-differenced phase data and range data with 1 m accuracy. Relevant configuration parameters for the tracking system and important sources of error are examined. The ability of these data to redetermine the position after a station keeping maneuver is addressed. The BRTS system, which is currently used for TDRSS orbit determination, is briefly described and its errors are given for comparison.
The radio metric tracking technique known as Same-Beam Interferometry (SBI) has been shown to improve orbit determination accuracy for the Magellan and Pioneer 12 orbiter. Previous efforts to explore the technique were carried out by making open loop recordings of the carrier signals from the two spacecraft and extracting their phases through post processing. This paper reports on the use of a closed loop receiver to simultaneously measure the carrier signals from two spacecraft in order to produce SBI data in near real time. The Experiment Tone Tracker is a digital closed loop receiver installed in two of NASA's Deep Space Network stations which can simultaneously extract the phase of up to eight tones. The receivers were used in late September and October of 1992 to collect Doppler and SBI data from Pioneer 12 and Magellan. The demise of the Pionner 12 on October 8th during the start-up phase of our tests precluded the collection of an extensive set of SBI data, however two passes of SBI and several arcs of single spacecraft Doppler data were recorded. The SBI data were analyzed and determined to have statistical errors consistent with error models and similar to open loop data.
Orbit determination results are presented for Magellan and Pioneer 12 utilizing same-beam interferometer (SBI) data, which is a new data type for planetary orbiter navigation. The orbit determination data employing this data type, based on orbit-to-orbit consistency, has been explained in terms of nominal error models. Results show the orbit determination accuracy for Pioneer 12 using Doppler plus SBI data to be better than the accuracy utilizing only Doppler data by 30 percent.