Search NASA⌕ Search

Engineering topics

Napolitano, J.

Publications and source records attributed to Napolitano, J..

Final Measurement of the 235 U Antineutrino Energy Spectrum with the PROSPECT-I Detector at HFIR

This Letter reports one of the most precise measurements to date of the antineutrino spectrum from a purely 235 U-fueled reactor, made with the final dataset from the PROSPECT-I detector at the High Flux Isotope Reactor. By extracting information from previously unused detector segments, this analysis effectively doubles the statistics of the previous PROSPECT measurement. Further, the reconstructed energy spectrum is unfolded into antineutrino energy and compared with both the Huber-Mueller model and a spectrum from a commercial reactor burning multiple fuel isotopes. A local excess over the model is observed in the 5–7 MeV energy region. Comparison of the PROSPECT results with those from commercial reactors provides new constraints on the origin of this excess, disfavoring at 2.0 and 3.7 standard deviations the hypotheses that antineutrinos from 235 U are solely responsible and noncontributors to the excess observed at commercial reactors, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration strategy of the PROSPECT-II detector with external and intrinsic sources

This paper presents an energy calibration scheme for an upgraded reactor antineutrino detector for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). The PROSPECT collaboration is preparing an upgraded detector, PROSPECT-II (P-II), to advance capabilities for the investigation of fundamental neutrino physics, fission processes and associated reactor neutrino flux, and nuclear security applications. P-II will expand the statistical power of the original PROSPECT (P-I) dataset by at least an order of magnitude. The new design builds upon previous P-I design and focuses on improving the detector robustness and long-term stability to enable multi-year operation at one or more sites. The new design optimizes the fiducial volume by elimination of dead space previously occupied by internal calibration channels, which in turn necessitates the external deployment. In this paper, we describe a calibration strategy for P-II. Here, the expected performance of externally deployed calibration sources is evaluated using P-I data and a well-benchmarked simulation package by varying detector segmentation configurations in the analysis. The proposed external calibration scheme delivers a compatible energy scale model and achieves comparable performance with the inclusion of an additional AmBe neutron source, in comparison to the previous internal arrangement. Most importantly, the estimated uncertainty contribution from the external energy scale calibration model meets the precision requirements of the P-II experiment.

47 OTHER INSTRUMENTATION↗

Precision Møller polarimetry for PREX-2 and CREX

The PREX-2 and CREX experiments in Hall A at Jefferson Lab are precision measurements of parity violating elastic electron scattering from complex nuclei. One requirement was that the incident electron beam polarization, typically , be known with 1% precision. We commissioned and operated a Møller polarimeter on the beam line that exceeds this requirement, achieving a precision of 0.89% for PREX-2, and 0.85% for CREX. The uncertainty is purely systematic, accumulated from several different sources, but dominated by our knowledge of the target polarization. Our analysis also demonstrates the need for accurate atomic wave functions in order to correct for the Levchuk Effect. We describe the details of the polarimeter operation and analysis, as well as (for CREX) a comparison to results from a different polarimeter based on Compton scattering.

43 PARTICLE ACCELERATORS↗

Accurate determination of the electron spin polarization in magnetized iron and nickel foils for Møller polarimetry

The Møller polarimeter in Hall A at Jefferson Lab in Newport News, VA, has provided reliable measurements of electron beam polarization for the past two decades. Past experiments have typically required polarimetry at the 1% level of absolute uncertainty which the Møller polarimeter has delivered. However, the upcoming proposed experimental program including MOLLER and SoLID have stringent requirements on beam polarimetry precision at the level of 0.4% (The MOLLER Collaboration, 2014; The SoLID collaboration, 2019), requiring a systematic re-examination of all the contributing uncertainties. Møller polarimetry uses the double polarized scattering asymmetry of a polarized electron beam on a target with polarized atomic electrons. The target is a ferromagnetic material magnetized to align the spins in a given direction. In Hall A, the target is a pure iron foil aligned perpendicular to the beam and magnetized out of plane parallel or antiparallel to the beam direction. The acceptance of the detector is engineered to collect scattered electrons close to 90° in the center of mass frame where the analyzing power is a maximum (-7/9). One of the leading systematic errors comes from determination of the target foil polarization. Polarization of a magnetically saturated target foil requires knowledge of both the saturation magnetization and g', the electron g-factor which includes components from both spin and orbital angular momentum from which the spin fraction of magnetization is determined. Target foil polarization has been previously addressed in a 1997 publication “A precise target for Møller polarimetry” by de Bever et al. (1997) at a level of precision sufficient for experiments up to this point. Several shortcomings with the previous published value require revisiting the result prior to MOLLER. Here, we utilize the existing world data to provide a best estimate for target polarization for both nickel and iron foils including uncertainties in magnetization, high-field and temperature dependence, and fractional contribution to magnetization from orbital effects. We determine the foil electron spin polarization at 294 K to be 0.08020 ± 0.00018 (@4 T applied field) for iron and 0.018845+/-0.000053 (@2 T applied field) for nickel. Finally, we conclude with a brief discussion of additional systematic uncertainties to Møller polarimetry using this technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision Determination of the Neutral Weak Form Factor of Ca 48

In this work, we report a precise measurement of the parity-violating asymmetry $A_{\rm PV}$ in the elastic scattering of longitudinally polarized electrons from $^{48}{\rm Ca}$. We measure $A_{\rm PV} =2668\pm 106\ {\rm (stat)}\pm 40\ {\rm (syst)}$ parts per billion, leading to an extraction of the neutral weak form factor $F_{\rm W} (q=0.8733$ fm$^{-1}) = 0.1304 \pm 0.0052 \ {\rm (stat)}\pm 0.0020\ {\rm (syst)}$ and the charge minus the weak form factor $F_{\rm ch} - F_{\rm W} = 0.0277\pm 0.0055$. The resulting neutron skin thickness $R_n-R_p=0.121 \pm 0.026\ {\rm (exp)} \pm 0.024\ {\rm (model)}$~fm is relatively thin yet consistent with many model calculations. The combined CREX and PREX results will have implications for future energy density functional calculations and on the density dependence of the symmetry energy of nuclear matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Physics with CEBAF at 12 GeV and future opportunities

Here, we summarize the ongoing scientific program of the 12 GeV Continuous Electron Beam Accelerator Facility (CEBAF) and give an outlook into future opportunities. The program addresses important topics in nuclear, hadronic, and electroweak physics, including nuclear femtography, meson and baryon spectroscopy, quarks and gluons in nuclei, precision tests of the standard model and dark sector searches. Potential upgrades of CEBAF and their impact on scientific reach are discussed, such as higher luminosity, the addition of polarized and unpolarized positron beams, and doubling the beam energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

PROSPECT-II physics opportunities

We report the precision reactor oscillation and spectrum experiment, PROSPECT, has made world-leading measurements of reactor antineutrinos at short baselines. In its first phase, conducted at the high flux isotope reactor (HFIR) at Oak Ridge National Laboratory, PROSPECT produced some of the strongest limits on eV-scale sterile neutrinos, made a precision measurement of the reactor antineutrino spectrum from 235 U, and demonstrated the observation of reactor antineutrinos in an aboveground detector with good energy resolution and well-controlled backgrounds. The PROSPECT collaboration is now preparing an upgraded detector, PROSPECT-II, to probe yet unexplored parameter space for sterile neutrinos and contribute to a full resolution of the reactor antineutrino anomaly, a longstanding puzzle in neutrino physics. By pressing forward on the world’s most precise measurement of the 235 U antineutrino spectrum and measuring the absolute flux of antineutrinos from 235 U, PROSPECT-II will sharpen a tool with potential value for basic neutrino science, nuclear data validation, and nuclear security applications. Following a two-year deployment at HFIR, an additional PROSPECT-II deployment at a low enriched uranium reactor could make complementary measurements of the neutrino yield from other fission isotopes. PROSPECT-II provides a unique opportunity to continue the study of reactor antineutrinos at short baselines, taking advantage of demonstrated elements of the original PROSPECT design and close access to a highly enriched uranium reactor core.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗