Nash, Charles A.

Publications and source records attributed to Nash, Charles A..

At least 19 records

Proton nuclear magnetic resonance (1H NMR) of flammable organic chemicals in radioactive high–level supernatant waste at the Savannah River Site (SRS)

The Savannah River Site stores approximately 36 million gallons of radioactive and hazardous waste that contains approximately 245 million curies. The waste is sent through various chemical processes to reduce its volume and to separate various components. The facility plans to replace formic acid (a chemical used to reduce soluble mercury) with glycolic acid. Recycle solution with glycolate may flow back to the tank farm, where the glycolate can generate hydrogen gas by thermal and radiolytic mechanisms. The current analytical method for detecting glycolate (ion chromatography) in supernatant requires a large dilution to reduce interference from the nitrate anions. Hydrogen nuclear magnetic resonance is an analytical method that requires less sample dilution. It takes advantage of the CH 2 group in glycolate. Liquid samples were spiked with four different levels of glycolate to build a calibration line, as it is recommended in the standard addition method. The detection and quantitation limits determined were 1 and 5 ppm, respectively, for 32 scans, which is well below the process limit of 10 ppm. In one test, 800 scans of a supernatant spiked with 1 ppm glycolate resulted in a -CH 2 peak with a signal-to-noise ratio of 36.

1H↗

Organic Evaporation and Oxidation Testing in Support of Hanford Sample-and-Send

The Hanford site has approximately 56 million gallons of radioactive mixed waste stored in 177 underground storage tanks. The Hanford Waste Treatment and Immobilization Plant (WTP) is being built to treat and immobilize the tank waste. The baseline method for immobilization of Low Activity Waste (LAW) through the WTP is vitrification, but additional immobilization capacity is needed to supplement the initial LAW melters. An alternative cementitious waste form is being investigated for that future immobilization method to supplement vitrification. However, one impediment to a cementitious waste form is the presence of Land Disposal Restricted (LDR) organic chemicals in tank waste. This work evaluates potential avenues to eliminate that impediment to permit possible use of a cementitious waste form and work towards a decision whether additional LDR organic pretreatment would be required. Savannah River National Laboratory (SRNL) performed testing using simulants to examine evaporation as a method to remove some prevalent organics from LAW. Spiking the caustic LAW simulant with selected regulated organic chemicals found one that clearly decomposes because of caustic instability. Oxidation testing of other organic chemicals found some LDR organics degrade as desired and others are stable in the presence of peroxide and permanganate. In addition to studies with simulants, a literature review was performed to evaluate radiological stability of LDR organics. Descriptions of the experimental details, equipment, and results are included in this report. Evaporation testing consisted of preparing the LAW simulant, spiking that simulant with organic chemicals, and evaporating the mixture via differential distillation. The apparatus was a laboratory-scale vacuum evaporator operated at 60 ±5 torr absolute (vacuum evaporation) and also at atmospheric pressure. The LAW simulant represented the liquid expected to be retrieved from the Hanford tank farms at approximately 4.0 M [Na + ] total sodium ion concentration. The concentration of the organic chemicals added was significantly higher than typically found in the tank waste samples since the higher levels were necessary to assist in analytical measurement and tracking of the spiked species. Organic chemicals were chosen for the work with a consideration of how their volatility compares with that of methanol. This was done by comparing the ratio of the pure water Henry’s law coefficient (K h ) of methanol to that of the compound in question (hereafter termed the K h ratio), where ratios above unity indicated less volatility than methanol. Methanol was chosen because it is a common regulated chemical with relatively low volatility but which has been removed by evaporation in previous laboratory work. While organic separation results depend on evaporator design, laboratory experiments verified that organic partitioning to the overhead condensate stream by evaporation is a practical process. The work reported here found difficulties in quantitative analysis of the organic chemicals in aqueous samples. Most of the time there was insufficient analysis to close a mass balance for evaporator runs, but qualitative evidence of carryover was obtained. The methods were also able to show whether organic chemicals were susceptible or resistant to solution oxidation in permanganate or hydrogen peroxide tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank 49H solids disturbance analysis

Tank 49H serves as the feed tank for the Salt Waste Processing Facility (SWPF). Transfers into Tank 49H may disturb any solids that have settled to the bottom of the tank, resulting in feed that may exceed the insoluble solids content limit of 1,200 mg/L of the SWPF Waste Acceptance Criteria (WAC). During a transfer into Tank 49H, material that free falls into Tank 49H through a downcomer could potentially disturb any solids on the bottom of the tank and scour or suspend solids from a settled solids layer or turbid region. A previous analysis and report evaluated the potential to disturb solids when transferring into Tank 49H through the B4 riser and recommended a minimum tank level of 120 inches to prevent disturbing any solids in the bottom of the tank. The scope of this task is to perform additional fluid flow analysis to determine whether accounting for disturbed particle settling and particle mixing and dispersion during transfer could allow the minimum liquid level to be reduced below 120 inches. The analysis utilized models from the technical literature to calculate the size and shape of the “plunging jet” as a function of input parameters such as initial velocity, initial jet diameter, elevation of the initial jet, liquid level in the tank, and solids depth. The analysis relied on the M-Star® simulations performed for the previous analysis to provide bounding estimates of the amount of solid particles disturbed and used the MStar® software to calculate the dispersion and mixing of the disturbed solids with other liquid in the tank as the solids are transported to the transfer pump. The analysis showed that with a solid particle size of 5 micron or less, a liquid level of 120 inches should be maintained to prevent significant disturbance of the solid layer at the bottom of Tank 49H.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis in Support of Disposition of Tank 48 Legacy Material

This report contains the characterization of six 200-mL Tank 48H samples: HTF-48-21-74, HTF-48-21-75, HTF-48-21-76, HTF-48-21-81, HTF-48-21-82, and HTF-48-21-83. The effort supports a Systems Engineering Evaluation (SEE) recommendation involving a Tank 48H decantation strategy that would remove liquid volume and grout the solids. The first three Tank 48H samples were surface samples taken after a quiescent period in the tank. The quiescent period allowed settling of the solids, these being mostly potassium tetraphenylborate. These three surface samples had no measurable solids, though a settling haze could be seen. The latter three samples were taken at 48, 25, and 10 inches from the bottom of Tank 48H immediately after tank mixing pumps had been run. Those samples contained measurable insoluble solids that were readily visible. All six samples were analyzed to provide chemical and radionuclide concentrations as defined as the "Limit" and "Target" in the Saltstone Production Facility (SPF) Waste Acceptance Criteria (WAC) and per the compliance strategy in the Tank Farm Waste Compliance Plan (WCP). Samples were analyzed by many methods to determine pH, density/specific gravity, radioactive isotopes, soluble and insoluble elements, total solids, total insoluble solids, organic and inorganic mercury, volatile and semi-volatile chemicals, and anions. Photographs of the settling of small samples were taken over time and are displayed in this report. The extent of settling was very significant, showing that surface sample liquids are similar to filtrates. However, Cs-137 measurements exceeded WAC limits in all surface samples (1.1E+07 vs. 1.3E+06). The solids were found to contain very high cesium activity, measured as high as 1.1E+10 dpm/gram. Sodium was in the range of 4.24 to 4.74 M for all samples, so the solids would tend to settle with time and would not be at risk of floating without air entrainment. No organic mercury was detected in this work.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis in Support of Disposition of Tank 48 Legacy Material

This report contains the characterization of six 200-mL Tank 48H samples: HTF-48-21-74, HTF-48-21-75, HTF-48-21-76, HTF-48-21-81, HTF-48-21-82, and HTF-48-21-83. The effort supports a Systems Engineering Evaluation (SEE) recommendation involving a Tank 48H decantation strategy that would remove liquid volume and grout the solids. The first three Tank 48H samples were surface samples taken after a quiescent period in the tank. The quiescent period allowed settling of the solids, these being mostly potassium tetraphenylborate. These three surface samples had no measurable solids, though a settling haze could be seen. The latter three samples were taken at 48, 25, and 10 inches from the bottom of Tank 48H immediately after tank mixing pumps had been run. Those samples contained measurable insoluble solids that were readily visible. All six samples were analyzed to provide chemical and radionuclide concentrations as defined as the "Limit" and "Target" in the Saltstone Production Facility (SPF) Waste Acceptance Criteria (WAC) and per the compliance strategy in the Tank Farm Waste Compliance Plan (WCP). Samples were analyzed by many methods to determine pH, density/specific gravity, radioactive isotopes, soluble and insoluble elements, total solids, total insoluble solids, organic and inorganic mercury, volatile and semi-volatile chemicals, and anions. Photographs of the settling of small samples were taken over time and are displayed in this report. The extent of settling was very significant, showing that surface sample liquids are similar to filtrates. However, Cs-137 measurements exceeded WAC limits in all surface samples (1.1E+07 vs. 1.3E+06). The solids were found to contain very high cesium activity, measured as high as 1.1E+10 dpm/gram. Sodium was in the range of 4.24 to 4.74 M for all samples, so the solids would tend to settle with time and would not be at risk of floating without air entrainment. No organic mercury was detected in this work.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Potential for Evaporation and In Situ Reaction of Organic Compounds in Hanford Supplemental LAW

The presence of regulated organic species in Hanford nuclear tank waste is assessed in this report, along with fate of the organics and possible evaporative treatment. A narrowed list of regulated organic species of concern is developed based upon published analyses, chemical properties like aqueous solubility, and chemical reactivity under alkaline conditions. Published analyses include tank headspace and liquid samples, review of chemical reagents formerly used at Hanford, and the Tank Waste Information Network System (TWINS). This work supports possible stabilization of Hanford Supplemental Low Activity Waste (SLAW) by grouting.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Potential for Evaporation and In Situ Reaction of Organic Compounds in Hanford Supplemental LAW

The presence of regulated organic species in Hanford nuclear tank waste is assessed in this report, along with fate of the organics and possible evaporative treatment. A narrowed list of regulated organic species of concern is developed based upon published analyses, chemical properties like aqueous solubility, and chemical reactivity under alkaline conditions. Published analyses include tank headspace and liquid samples, review of chemical reagents formerly used at Hanford, and the Tank Waste Information Network System (TWINS). This work supports possible stabilization of Hanford Supplemental Low Activity Waste (SLAW) by grouting.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Batch Contact Equilibrium Testing of Crystalline Silicotitanate (CST) Sieve Cuts in SRS Average Simulant and Examination of CST Samples Aged in Caustic and Simulant in Support of Tank Closure Cesium Removal 1A (TCCR-1A)

Batch contact testing to determine cesium equilibrium loading on Crystalline Silicotitanate ion exchange media in Savannah River Site Average Waste Simulant at 25 °C indicated that smaller diameter particles isolated by sieving pretreated CST media may load slightly higher (<10%) amounts of cesium, though the differences are within analytical uncertainty. In addition, ion exchange media sub-samples stored in 2-4 M NaOH and caustic simulant solutions for ~2.5 years were examined by optical microscopy and the 3 M NaOH sample was also analyzed to determine whether changes in the particle size distribution occurred during storage. No visual indications of particle attrition or agglomeration were observed for any sample. Particle size analysis indicated that a slight decrease occurred in the average particle diameter following contact with 3 M NaOH (541 µm average diameter versus 566 µm for the pretreated CST prior to contact). A small increase (from 0 to <0.5 wt. %) in the number of particles ranging from 271 and 322 µm was also observed for the CST sample contacted with 3 M NaOH relative to a sample of the original pretreated material. However, this small change could be due to sub-sampling differences or analytical uncertainty. It does not appear that small particles are formed to a significant degree during CST caustic contact or that small particles which do form (presumably from attrition of larger particles during pretreatment) load significantly more cesium than the bulk material. Minimal other negative consequences were observed associated with CST extended caustic or simulant contact, except for the tendency for more concentrated salt solutions to form some salt crystals which deposit on the media over time.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling of Glycolate Destruction in the Recycle Collection Tank

The Savannah River Site’s DWPF is being upgraded with the introduction of the NG flowsheet. Glycolic acid has been shown to be a superior alternative to formic acid for sludge processing. The new flowsheet improves or maintains necessary parameters such as 1) reduction of mercury, 2) adjustment of feed rheology, 3) pH stability, and 4) adjustment of melter oxidation/reduction potential. Further, the use of glycolic acid virtually eliminates the potential for catalytic hydrogen generation in DWPF processing DWPF process condensates are collected and returned to the Savannah River Site (SRS) CSTF. The RCT collects off-gas condensate during chemical processing, vitrification, and other unit operations performed in DWPF and is the singular return vessel delivering recycle effluent back to CSTF. Each batch of recycle will have a small amount of glycolate from chemical processing and melter off-gas condensates. To avoid potential flammability issues due to thermolysis of glycolate in the CSTF, Savannah River National Laboratory (SRNL) provided to Savannah River Remediation (SRR) at their request a Task Technical and Quality Assurance Plan (TTQAP) to quantify and mitigate glycolate returns via DWPF’s recycle stream. The request included testing of a process to oxidize glycolate and other organic species that are responsible for hydrogen generation from thermolysis. Following that work SRR provided a Task Technical Request (TTR) that requested process modeling. In 2021 a TTQAP was issued to cover the modeling work. Modeling draws data from laboratory scale studies using chemical simulants and radioactive waste samples. Chemical kinetic modeling was performed to evaluate the feasibility of using sodium permanganate to destroy glycolate in the RCT. The results from the laboratory studies were summarized in a series of reports. Reference 9 is a report of lab scale processing of actual DWPF Slurry Mix Evaporate Condensate Tank (SMECT) and Offgas Condensate Tank (OGCT) samples in the SRNL Shielded Cells. Tests at caustic conditions demonstrated sodium permanganate was effective in converting glycolate to oxalate, and permanganate (Mn 7+ ) is reduced to manganate (Mn 6+ ) with no significant formation of carbon dioxide or carbonate. Equation (1) was found to best describe the observed reaction of glycolate with permanganate under nominal (60 to 145 mg/L in RCT) glycolate entrainment conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Supplemental Low Activity Waste Simulant Evaporation Testing for Removal of Organics

The Hanford site has approximately 56 million gallons of radioactive waste stored in 177 underground storage tanks. The Hanford Waste Treatment and Immobilization Plant (WTP) is being built to treat and immobilize the tank waste. The baseline method for immobilization of Low Activity Waste (LAW) is vitrification, but additional immobilization capacity is likely needed to supplement the initial melters. An alternative cementitious waste form is being investigated for that future supplemental immobilization method. However, one impediment to a cementitious waste form is the presence of Land Disposal Restricted (LDR) organic chemicals in tank waste. Developing a method to remove the organics would eliminate that impediment to permit possible use of a cementitious waste form. Savannah River National Laboratory (SRNL) performed testing to examine evaporation as a method to remove some prevalent organics from the Supplemental LAW (SLAW) stream. Samples of product streams from the evaporation were analyzed to determine partitioning of the organics. Modeling was also performed to determine if the experimental and modeling results matched. A description of the experimental details, equipment, and results of that testing are included in this report.The work is intended to inform future SLAW flowsheet development activities and gather useful data about the partitioning of constituents through a possible SLAW feed evaporator.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Technologies for Enhancing Grout for Immobilizing Hanford Supplemental Low-Activity Waste (SLAW)

An expert panel consisting of the document authors was assembled by Washington River Protection Solutions, LLC (WRPS) and tasked with (1) identifying technical and regulatory limitations to treating and disposing of grouted low-activity waste (LAW), and (2) with identifying and evaluating a wide range of technical solutions to these limitations. The analysis included technologies to allow inventory management and/or improve retention of iodine, technetium, and nitrate either in the waste packages, or within the Integrated Disposal Facility (IDF), and, technologies to ensure regulated organics are below Resource Conservation and Recovery Act of 1976 (RCRA) Land Disposal Restriction (LDR) levels.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling the Destruction of Glycolate in the Defense Waste Processing Facility (DWPF) Recycle Stream and Concentration Factors for Glycolate in the 2H Evaporator

Two models were developed to predict maximum glycolate concentrations in the Savannah River Site (SRS) Concentration, Storage, and Transfer Facility (CSTF) from implementation of the Nitric-Glycolic flowsheet at the Defense Waste Processing Facility (DWPF). One model describes the kinetics of glycolate destruction via chemical oxidation with sodium permanganate. This model conservatively predicts glycolate concentration delivered to the CSTF with a high probability the actual glycolate concentration is lower than predicted. The second model describes the potential concentration of said residual glycolate within the 242-16H (i.e., “2H”) Evaporator system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Summary of Analytical Results from Samples Supporting Tank Closure Cesium Removal (TCCR) Batch 3 and Modeling Results for Cs Loading on CST

Savannah River Remediation (SRR) is currently operating the Tank Closure Cesium Removal (TCCR) process to remove 137 Cs from tank waste supernate using an ion exchange process. As part of that process, Savannah River National Laboratory (SRNL) receives and analyzes samples in support of the qualification of each batch to be processed. SRNL recently received supernate samples retrieved from Tank 10H as well as in-tank batch contact samples for characterization in support of qualifying Batch 3 for processing through the TCCR unit. Some results from analysis of those samples have been previously reported. This report documents the remaining analyses of the in-tank batch contact samples as well as the results of ZAM (Zheng, Anthony, Miller) isotherm modeling performed for comparison to the measured results. Results of the additional analyses include analysis of the loading of other radionuclides besides 137 Cs on the crystalline silicotitanate (CST) contained within the in-tank batch contact test samples. Results from those analyses revealed the next highest contributor to the activity on the CST was 90 Sr with an average loading of 2.76E+08 dpm/g CST compared to 3.56E+10 dpm/g CST for the 137Cs. Isotopes of plutonium were also detected on the samples. ZAM modeling was performed using the measured composition of the Tank 10H Batch 3 qualification samples. The modeling predicted a maximum Cs loading approximately 2.2x higher than the measured result. This is a slightly lower ratio (expected/measured) compared to what was observed for the prior TCCR in-tank batch contact testing performed for Batches 1A and 2 where the ZAM results were 2.7-2.8x higher than the measured values.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ZAM Modeling Study to Support the Tank Closure Cesium Removal (TCCR) 1A Unit

Currently at the Savannah River Site (SRS), the Tank Closure Cesium Removal (TCCR) is an “at-tank” process designed to remove cesium from aqueous tank waste. Cesium will be removed by ion exchange using the engineered IONSIV® R9120 form of Crystalline Silicotitanate (CST) media. The current TCCR design has two columns online in a lead-lag configuration to optimize media usage and achieve the target decontamination. Once the lead column is saturated with cesium, it will be removed from service, the lag column will rotate into the lead position, and a new column with fresh ion-exchange media will be placed into the lag position. The TCCR process for cesium removal from Tank 10H is detailed in X-SOW-H- 00002. Demonstration of the system began in early calendar year 2019 with two batches of salt solution generated by dissolving saltcake in Tank 10H, followed by processing of these batches through the TCCR system. A third TCCR Tank 10H dissolved saltcake batch is scheduled for processing soon. Upon completion of the demonstration with Tank 10H dissolved saltcake, Tank 9H salt solution will be transferred to Tank 10H and subsequently processed through the TCCR unit with new CST media (referred to as R9120-B 30x60) added to new IX columns. The TCCR processing campaign of Tank 9H salt solution is referred to as TCCR-1A .

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Summary of Expedited Results from Samples Supporting Tank Closure Cesium Removal (TCCR) Batch 3

Savannah River Remediation (SRR) is currently operating the Tank Closure Cesium Removal (TCCR) process to remove 137 Cs from tank waste supernate using an ion exchange process. As part of that process, Savannah River National Laboratory (SRNL) receives and analyzes samples in support of the qualification of each batch to be processed. SRNL recently received supernate samples retrieved from Tank 10H as well as in-tank batch contact samples for characterization in support of qualifying Batch 3 for processing through the TCCR unit. SRNL received and characterized a set of dip samples collected from Tank 10H (one surface and one variable depth sample). No solids were observed in either sample and therefore the samples were combined, and a suite of analyses were performed on the composite sample. The density of the combined sample was 1.174 g/mL (0.18 %RSD), which was consistent with the measured sodium concentration of 3.54 M (0.08 %RSD). The 137Cs activity in the sample was 4.75E+07 dpm/mL (4.28 %RSD) and the total Cs concentration was calculated to be 1.54 mg/L (1.16E-05 M). The in-tank batch contact samples consist of 0.1 g of crystalline silicotitanate (CST) contained within a teabag device. Duplicate samples were submerged in Tank 10H supernate for a period of about 13 days, after which time they were retrieved and transferred to SRNL for analysis. At SRNL the CST was rinsed to remove excess salt solution and the CST was then air dried before being digested for analysis. Results of the analysis indicated a 137 Cs loading of 3.66E+10 ± 1.40E+09 dpm/g or 16.5 ± 0.63 Ci/kg CST . This value represents a bounding upper limit as it includes the addition of two sigma uncertainty from replicate analysis of the individual teabag samples as well as the addition of the small amount of 137 Cs activity measured in the rinse solutions. The above values are based on the air-dried mass of CST. Correcting to the true dry mass using a F-factor of 0.8191 results in a maximum loading of 20.2 ± 0.77 Ci/kg CST .

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Removal Performance Comparisons of Crystalline Silicotitanate Media Batches with Savannah River Site Waste Simulant

The Tank Closure Cesium Removal (TCCR) system uses ion exchange columns filled with Crystalline Silicotitanate (CST) media to process radioactive waste solutions for the removal of Cs- 137. The TCCR project is currently focused on dissolving Savannah River Site (SRS) Tank 10H waste (primarily sodium salt cake solids) within the tank followed by at-tank ion exchange column treatment. Plans are underway to prepare and install a second TCCR unit at SRS. Capacity and particle size differences exist between archived (IE-911) and more recently prepared CST media batches (9120-B and 9140-B). Side-by-side comparison testing was performed to evaluate the cesium removal performance of each batch to aid in selecting the preferred CST batch and media characteristics to load into the second TCCR unit. Batch contact equilibrium and flow-through column tests have been conducted with three CST batches using an SRS Average Simulant.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Permanganate Oxidation of Actual Defense Waste Processing Facility (DWPF) Slurry Mix Evaporator Condensate Tank (SMECT) and Offgas Condensate Tank (OGCT) Samples to Remediate Glycolate

Savannah River Remediation (SRR) tasked Savannah River National Laboratory (SRNL) to examine glycolate destruction in radioactive samples emulating the proposed process. Experiments with radioactive Defense Waste Processing Facility (DWPF) condensates were performed to demonstrate the oxidation of glycolate using sodium permanganate. One test each was performed for Off-Gas Condensate Tank (OGCT) and Slurry Mix Evaporator Condensate Tank (SMECT) samples received. Condensates were blended with Recycle Collection Tank (RCT) heel simulant and Slurry Mix Evaporator (SME) product containing glycolate to represent typical RCT compositions with estimated nominal entrainment of glycolate. A permanganate to glycolate (P/G) molar ratio targeting 5.7 decreased sample glycolate concentration below Ion Chromatography (IC), glycolate method reporting limits in less than 2 hours for the OGCT sample and in less than 8 hours for the SMECT sample.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Removal Performance Comparisons of Crystalline Silicotitanate Media Batches with Savannah River Site Waste Simulant

The Tank Closure Cesium Removal (TCCR) system uses ion exchange columns filled with Crystalline Silicotitanate (CST) media to process radioactive waste solutions for the removal of Cs137. TCCR currently focuses on dissolving Savannah River Site (SRS) Tank 10H waste (primarily sodium salt cake solids) within the tank followed by at-tank ion exchange column treatment. Plans are underway to prepare and install a second TCCR unit at SRS. Capacity and particle size differences exist between archived (IE-911) and more recently-prepared CST media batches (9120- B and 9140-B). Side-by-side comparison testing was performed to evaluate the cesium removal performance of each batch to aid in selecting the preferred CST batch and media characteristics to load into the second TCCR unit. Batch contact equilibrium and flow-through column tests have been conducted with three CST batches using an SRS Average Simulant. Simulant batch contact equilibrium cesium loading results for the three CST batches (including two lots of one batch) are provided in Table ES-1. The 35 °C data indicates that the archived IE-911 batch has a higher cesium capacity than recently-prepared CST media and that the minor TCCR CST 9120-B media lot (2099000035) has similar cesium removal performance to the major TCCR lot (2099000034). Tests conducted at 25 ºC for the archived IE-911 CST batch indicated lower cesium removal performance with this simulant batch than was observed recently with a different SRS Average Simulant batch. A dilution factor (DF) is typically utilized when modeling engineered CST media cesium loading performance to account for mass contributions from the binder material. In cases where CST performance is lower than expected, this factor includes corrections for the binder and for low performance. The ZAM (Zheng, Anthony, and Miller) Isotherm Model DF values are provided in Table ES-1 for each simulant batch contact result. DF values near 0.5 were determined for the 9120-B and 9140-B CST batch contact tests while DF values near 0.6 (20% higher) were determined for the tests with IE-911. These dilution factors are lower than recently observed with a different SRS Average Simulant batch (9140-B DF = 0.68; IE-911 DF = 1.0). Based on these results, it appears that some component in the simulant solution used for equilibrium testing may have resulted in reduced cesium loading on the CST media.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗