Search NASA⌕ Search

Engineering topics

Nassiri, A

Publications and source records attributed to Nassiri, A.

Status of the Short-Pulse X-ray Project at the Advanced Photon Source

The Advanced Photon Source Upgrade (APS-U) Project at Argonne will include generation of short-pulse x-rays based on Zholents deflecting cavity scheme. We have chosen superconducting (SC) cavities in order to have a continuous train of crabbed bunches and flexibility of operating modes. In collaboration with Jefferson Laboratory, we are prototyping and testing a number of single-cell deflecting cavities and associated auxiliary systems with promising initial results. In collaboration with Lawrence Berkeley National Laboratory, we are working to develop state-of-the-art timing, synchronization, and differential rf phase stability systems that are required for SPX. Collaboration with Advanced Computations Department at Stanford Linear Accelerator Center is looking into simulations of complex, multi-cavity geometries with lower- and higher-order modes waveguide dampers using ACE3P. This contribution provides the current R&D status of the SPX project.

43 PARTICLE ACCELERATORS↗

Low Impedance Bellows for High-current Beam Operations

In particle accelerators, bellows are commonly used to connect beamline components. Such bellows are traditionally shielded to lower the beam impedance. Excessive beam impedance can cause overheating in the bellows, especially in high beam current operation. For an SRF-based accelerator, the bellows must also be particulate free. Many designs of shielded bellows incorporate rf slides or fingers that prevent convolutions from being exposed to wakefields. Unfortunately these mechanical structures tend to generate particulates that, if left in the SRF accelerator, can migrate into superconducting cavities, the accelerator's critical components. In this paper, we describe a prototype unshielded bellows that has low beam impedance and no risk of particulate generation.

43 PARTICLE ACCELERATORS↗

High-power Waveguide Dampers for the Short-Pulse X-Ray Project at the Advanced Photon Source

High-power waveguide dampers have been designed and prototyped for the Short-Pulse X-ray (SPX) cavities at the Advanced Photon Source. The cavities will operate at 2.815 GHz and utilize the TM110 dipole mode. As a result, higher-order (HOM) and lower-order mode (LOM) in-vacuum dampers have been designed to satisfy the demanding broadband damping requirements in the APS storage ring. The SPX single-cell cavity consists of two WR284 waveguides for damping the HOMs and one WR284 waveguide for primarily damping the LOM where up to 2kW will be dissipated in the damping material. The damper designs and high-power experimental results will be discussed in this paper.

43 PARTICLE ACCELERATORS↗

Higher Order Modes Damping Analysis for the SPX Deflecting Cavity Cyromodule

A single-cell superconducting deflecting cavity operating at 2.815 GHz has been proposed and designed for the Short Pulse X-ray (SPX) project for the Advanced Photon Source (APS) upgrade. A cryomodule of 4 such cavities will be needed to produce the required 2-MV deflecting voltage. Each deflecting cavity is equipped with one fundamental power coupler (FPC), one lower order mode (LOM) coupler, and two higher order mode (HOM) couplers to achieve the stringent damping requirements for the unwanted modes. The damping of the LOM/HOM below the beampipe cutoff has been analyzed in the single cavity geometry and shown to meet the design requirements. The HOM above the beampipe cutoff in the 4-cavity cyromodule, however, may result in cross coupling which may affect the HOM damping and potentially be trapped between the cavities which could produce RF heating to the beamline bellows. We have evaluated the HOM damping in the 4-cavity cryomodule using the parallel finite element EM code suite ACE3P developed at SLAC. We will present the results of the cryomodule analysis in this paper.

43 PARTICLE ACCELERATORS↗

Changes to the Advanced Photon Source storage ring as part of the APS renewal project

The Advanced Photon Source (APS) is a third-generation, storage-ring-based x-ray source that has been operating for more than 13 years and is enjoying a long period of stable, reliable operation. While APS is presently providing state-of-the-art performance to its large user community, we must clearly plan for improvements and upgrades to stay at the forefront scientifically. Significant improvements should be possible through upgrades of beamline optics, detectors, and end-station equipment. In this paper, we discuss the evolutionary changes that are envisioned for the storage ring itself. Among the possibilities are long straight sections, additional straight sections, higher current, short-pulse x-rays, improved insertion devices, and improved beam stability.

43 PARTICLE ACCELERATORS↗

Design and study of a high-current 5-cell superconducting rf cavity.

The Advanced Photon Source (APS) at Argonne National Laboratory is considering the development of a superconducting linac-based fourth-generation hard X-ray source to meet future scientific needs of the hard X-ray user community. This work specifically focuses on the design of an optimized 5-cell superconducting radio-frequency structure well suited for a high-energy, high-beam-current energy recovery linac. The cavity design parameters are based on the APS storage ring nominal 7 GeV and 100 mA beam operation. A high-current 5-cell cw superconducting cavity operating at 1.4 GHz has been designed. In order to achieve a high current, the accelerating cavity shape has been optimized and large end-cell beam pipes have been adopted. The beam break-up threshold of the cavity has been estimated using the code TDBBU, which predicts a high threshold beam current for a 7 GeV energy recovery linac model. A copper prototype cavity has been fabricated that uses half-cell modules, initially assembled by clamping the cells together.

43 PARTICLE ACCELERATORS↗

Observations of rising tune during the injection instability of IPNS RCS proton bunch.

In the rapid cycling synchrotron (RCS), a single proton bunch (h=1) is accelerated from 50 MeV to 450 MeV in approximately 14.2 ms. The bunch experiences an instability shortly after injection (<1 ms). During the first millisecond, the beam is bunched but little acceleration takes place; therefore this period is similar to a storage ring mode of operation. Natural vertical oscillations (assumed to be tune lines) show the vertical tune to be rising toward the bare tune value, suggesting neutralization of space charge and a reduction of its detuning effects. Neutralization time near injection ranges from 250 mus - 500 mus, depending on the background gas pressure. Oscillations move from the LSB to the USB before disappearing. Tune measurements made with a recently installed ferrite- magnet pinger system show the horizontal chromaticity to be positive early but approaching zero later in the cycle; on the other hand, the vertical chromaticity is negative throughout the cycle. During pinger studies near injection, two vertical lines are observed. Neutralization of the beam space charge implies the generation of plasma in the beam volume early in the cycle which may then dissipate as the time-varying electric fields of the beam become stronger.

43 PARTICLE ACCELERATORS↗

Vertical Instability at IPNS RCS.

The rapid cycling synchrotron (RCS) of the intense pulsed neutron source (IPNS) at ANL accelerates > 3.0 times 10{sup 12} protons from 50 MeV to 450 MeV with 30-Hz repetition frequency. During the acceleration cycle, the rf frequency varies from 2.21 MHz to 5.14 MHz. Presently, the beam current is limited by a vertical instability. By analyzing turn-by-turn beam position monitor (BPM) data, large- amplitude mode 0 and mode 1 vertical beam centroid oscillations were observed in the later part of the acceleration cycle. The oscillations start in the tail of the bunch, build up, and remain localized in the tail half of the bunch. This vertical instability was compared with a head-tail instability that was intentionally induced in the RCS by adjusting the trim sextupoles. It appears that our vertical instability is not a classical head-tail instability [1]. More data analysis and experiments were performed to characterize the instability.

43 PARTICLE ACCELERATORS↗

The IPNS second harmonic RF upgrade.

The intense pulsed neutron source (IPNS) rapid cycling synchrotron (RCS) is used to accelerate protons from 50 MeV to 450 MeV, at a repetition rate of 30 Hz. The original ring design included two identical rf systems, each consisting of an accelerating cavity, cavity bias supply, power amplifiers and low-level analog electronics. The original cavities are located 180 degrees apart in the ring and provide a total peak accelerating voltage of {approx}21 kV over the 2.21-MHz to 5.14-MHz revolution frequency sweep. A third rf system has been constructed and installed in the RCS. The third rf system is capable of operating at the fundamental revolution frequency for the entire acceleration cycle, providing an additional peak accelerating voltage of up to {approx}11 kV, or at the second harmonic of the revolution frequency for the first {approx}4 ms of the acceleration cycle, providing an additional peak voltage of up to {approx}11 kV for bunch shape control. We describe here the hardware implementation and operation to date of the third rf cavity in the second harmonic mode.

43 PARTICLE ACCELERATORS↗

Short x-ray pulse generation using deflecting cavities at the Advanced Photon Source.

Storage-ring-based third-generation light sources can provide intense radiation pulses with durations as short as 100 ps. However, there is growing interest within the synchrotron radiation user community in performing experiments with much shorter X-ray pulses. Zholents et al. [Nucl. Instr. and Meth. A 425 (1999) 385] recently proposed using RF orbit deflection to generate sub-ps X-ray pulses. In this scheme, two deflecting cavities are used to deliver a longitudinally dependent vertical kick to the beam. An optical slit can then be used to slice out a short part of the radiation pulse. Implementation of this scheme is planned for one APS beamline in the near future. In this paper, we summarize our feasibility study of this method and the expected X-ray beam parameters. We find that a pulse length of less than two picoseconds can be achieved.

43 PARTICLE ACCELERATORS↗

Potential performance and challenges of an energy recovery linac upgrade to the Advanced Photon Source.

The Advanced Photon Source (APS) is a third-generation synchrotron radiation source operating at 7 GeV that has been in operation for over 10 years. In that time, the emittance has been improved from 8 to 3.1 nm, which is close to the practical minimum. Recently, APS undertook an intensive exploration of potential upgrades, including options for a replacement storage ring or Energy Recovery Linac (ERL) injector. Our conclusion was that only the ERL would provide a dramatically new capability. This paper discusses the potential performance available from an ERL upgrade to the APS and reviews the challenges of delivering this performance.

43 PARTICLE ACCELERATORS↗

Planned Use of Pulsed Crab Cavities for Short X-Ray Pulse Generation at the Advanced Photon Source

Recently, we have explored application to the Advanced Photon Source (APS) of Zholents'[1] crab cavity scheme for production of short x-ray pulses. We assumed use of superconducting (SC) cavities in order to have a continuous stream of crabbed bunches and flexibility of operating modes. The challenges of the SC approach are related to the size, cost, and development time of the cavities and associated systems. A good case can be made [2] for a pulsed system using room-temperature cavities. APS has elected to pursue such a system in the near term, with the SC-based system planned for a later date. This paper describes the motivation for the pulsed system and gives an overview of the planned implementation and issues. Among these are overall configuration options and constraints, cavity design options, frequency choice, cavity design challenges, tolerances, instabilities, and diagnostics plans.

43 PARTICLE ACCELERATORS↗