Extreme ultraviolet microscope characterization using photomask surface roughness

We demonstrate a method for characterizing the field-dependent aberrations of a full-field synchrotron-based extreme ultraviolet microscope. The statistical uniformity of the inherent, atomic-scale roughness of readily-available photomask blanks enables a self-calibrating computational procedure using images acquired under standard operation. We characterize the aberrations across a 30-um field-of-view, demonstrating a minimum aberration magnitude of smaller than λ/21 rms averaged over the center 5-um area, with a measurement accuracy better than λ/180 rms. The measured field variation of aberrations is consistent with system geometry and agrees with prior characterizations of the same system. In certain cases, it may be possible to additionally recover the illumination wavefront from the same images. Our method is general and is easily applied to coherent imaging systems with steerable illumination without requiring invasive hardware or custom test objects; hence, it provides substantial benefits when characterizing microscopes and high-resolution imaging systems in situ.

47 OTHER INSTRUMENTATION↗

EUV photolithography mask inspection using Fourier ptychography

Fourier ptychography is a computational imaging techniques that combines various full-field coherent images acquired under varied illumination angles and combined to yield a angular spectrum with a large synthetic numerical aperture and non-interferometric phase information. We present here the implementation of this technique in a full-field soft x-ray microscope designed to emulate modern EUV lithography tools imaging conditions, and we show that this technique can be used for the study of EUV photomasks. The technique allows us to quantitatively characterize phase defects (predominant in EUV lithography), to study new mask designs made of phase structures, to study sub-resolution assist features and extend the resolution of the microscope down to 26-nm, correspond to the N1 technology node.

Wojdyla, Antoine↗

Amplitude versus phase effects in extreme ultraviolet lithography mask scattering and imaging

It is well established that extreme ultraviolet (EUV) mask multilayer roughness leads to wafer-plane linewidth roughness (LWR) in the lithography process. Analysis and modeling done to date has assumed, however, that the roughness leading to scatter is primarily a phase effect and that the amplitude can be ignored. Under this assumption, simple scattering measurements can be used to characterize the statistical properties of the mask roughness. Here, we explore the implications of this simplifying assumption by modeling the imaging impacts of the roughness amplitude component as a function of the balance between amplitude and phase induced scatter. In addition to model-based analysis, we also use an EUV microscope to compare experimental through focus data to modeling in order to assess the actual amount of amplitude roughness on a typical EUV multilayer mask. The results indicate that amplitude roughness accounts for less than 1% of the total scatter for typical EUV masks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of shot noise in photoresists for extreme ultraviolet lithography through comparative analysis of line edge roughness in electron beam and extreme ultraviolet lithography

In this paper, the influence of the absorption shot noise on line edge roughness (LER) of photoresists for extreme ultraviolet (EUV) lithography is studied experimentally through the comparative analysis of LER obtained by EUV (92 eV photons) and 100 keV e-beam lithography. Techniques for performing EUV and e-beam lithography with a matched image log slope for a fair comparison of LER values are described. Measurements of absorption of 100 keV electrons estimated through a transmissive electron energy loss spectroscopy measurement with a 120 keV electron beam showed that despite having access to core levels in the material (e.g., 284 eV edge in carbon), these electrons mostly just excite the energy levels less than 100 eV in the resist, with a mean deposited energy of 35 eV. By combining the incident flux and the absorption probabilities, the absorbed quanta for patterning of 50 nm half-pitch line/space features was found to be similar between the two patterning technologies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficient Fresnel zoneplate pattern data preparation for high-resolution nanofabrication

A Fresnel zoneplate is a diffractive optical element consisting of concentric rings (zones) for which the transmitted light produces a focal spot that is used in all wavelength regimes, including X-rays. The pattern of transmission openings determines the location of the spot and the sub-half wavelength size of the openings can adjust the intensity. Today, very general transmission zoneplate patterns are used for many special imaging and image compensation purposes. Manufacturing zoneplates require a zoneplate pattern file, which precisely describes the size, shape, and contour of the rings based on the desired optical properties of the lens. Generating such a pattern requires the delicate balance of achieving the required optical performance while maintaining manageable file sizes and computation times. Here we describe a new algorithm meeting these needs. In conclusion, by precisely controlling the number of shapes in each zone, the algorithm simultaneously optimizes the desired optical tolerances with the pattern file size.

47 OTHER INSTRUMENTATION↗

Impact of tool design on defect detection sensitivity in extreme ultraviolet actinic blank inspection

Here, we discuss the impact of various tool design perspectives on defect detection sensitivity for dark-field-based extreme ultraviolet (EUV) actinic blank inspection. We consider the impact of pixel size, EUV source type, and photon collection efficiency on critical defect signal-to-noise ratio (SNR) performance. The results show that as the pixel size approaches the target defect image size, defect SNR increases, and that pixel size also determines the dominant noise source in the inspection system. Moreover, the choice of the EUV source affects the optimal numerical aperture (NA) and illumination settings. For plasma-discharged sources, more photons provided by larger partial coherent illumination can improve the defect SNR, while coherent illumination is needed to get a higher defect SNR for synchrotron-based source. In the end, we show that simply increasing the photon collection efficiency by using high-NA optics or increasing the source power cannot always improve the defect SNR. In a speckle-noise dominated situation, larger outer NA includes more noise than defect signal, thus resulting in a lower SNR. The impact of source power also saturates at a certain level as the system becomes speckle-noise limited compared to photon-noise limited.

42 ENGINEERING↗

Impact of noise sources and optical design on defect detection sensitivity in extreme ultraviolet actinic pattern inspection tool

Here, we discuss the impact of various noise sources and the optical design in bright field extreme ultraviolet (EUV) actinic inspection of mask features for defects in the patterned absorber. It is shown that an optimum pixel size is needed to maximize the defect signal-to-noise ratio (SNR) to balance the trade-off in increasing signal strength with shot noise from defect signal and the background pattern intensity (mask layout image) and speckle noise from the mask blank roughness. Moreover, we consider defocus showing that the EUV mask phase effect has an asymmetric impact on pattern defect SNR's through-focus behavior. The impact of defocus limits inspection performance based on defect SNR. Using critical defect sizes in a case study, we show the defect SNR performance of the limiting case and discuss the possibility of utilizing a nominal defocus in the inspection system to leverage the phase effect of EUV mask absorber to improve the defect SNR. A 50% improvement in defect SNR is shown to be possible by introducing a -50 nm nominal defocus into the bright field inspection system.

42 ENGINEERING↗

Emulation of anamorphic imaging on the SHARP extreme ultraviolet mask microscope

The SHARP high-numerical aperture actinic reticle review project is a synchrotron-based, extreme ultraviolet (EUV) microscope dedicated to photomask research. SHARP emulates the illumination and imaging conditions of current EUV lithography scanners and those several generations into the future. An anamorphic imaging optic with increased mask-side numerical aperture (NA) in the horizontal and increased demagnification in the vertical direction has been proposed in this paper to overcome limitations of current multilayer coatings and extend EUV lithography beyond 0.33 NA. Zoneplate lenses with an anamorphic 4×/8× NA of 0.55 are fabricated and installed in the SHARP microscope to emulate anamorphic imaging. SHARP’s Fourier synthesis illuminator with a range of angles exceeding the collected solid angle of the newly designed elliptical zoneplates can produce arbitrary angular source spectra matched to anamorphic imaging. A target with anamorphic dense features down to 50-nm critical dimension is fabricated using 40 nm of nickel as the absorber. In a demonstration experiment, anamorphic imaging at 0.55 4×/8× NA and 6 deg central ray angle (CRA) is compared with conventional imaging at 0.5 4× NA and 8 deg CRA. A significant contrast loss in horizontal features is observed in the conventional images. Finally, the anamorphic images show the same image quality in the horizontal and vertical directions.

36 MATERIALS SCIENCE↗

Quantitative phase retrieval with arbitrary pupil and illumination

We present a general algorithm for combining measurements taken under various illumination and imaging conditions to quantitatively extract the amplitude and phase of an object wave. The algorithm uses the weak object transfer function, which incorporates arbitrary pupil functions and partially coherent illumination. The approach is extended beyond the weak object regime using an iterative algorithm. Finally, we demonstrate the method on measurements of Extreme Ultraviolet Lithography (EUV) multilayer mask defects taken in an EUV zone plate microscope with both a standard zone plate lens and a zone plate implementing Zernike phase contrast.

97 MATHEMATICS AND COMPUTING↗

Phase measurements of EUV mask defects

Extreme Ultraviolet (EUV) Lithography mask defects were examined on the actinic mask imaging system, SHARP, at Lawrence Berkeley National Laboratory. Also, a quantitative phase retrieval algorithm based on the Weak Object Transfer Function was applied to the measured through-focus aerial images to examine the amplitude and phase of the defects. The accuracy of the algorithm was demonstrated by comparing the results of measurements using a phase contrast zone plate and a standard zone plate. Using partially coherent illumination to measure frequencies that would otherwise fall outside the numerical aperture (NA), it was shown that some defects are smaller than the conventional resolution of the microscope. We found that the programmed defects of various sizes were measured and shown to have both an amplitude and a phase component that the algorithm is able to recover.

42 ENGINEERING↗