Search NASA⌕ Search

Engineering topics

Nawani, Pranav

Publications and source records attributed to Nawani, Pranav.

Fluorescence-Based Aqueous Phosphate Sensing Using Eu(cpboda)(DMF) 2

Fluorescence-based phosphate sensing using phosphate-sensitive phosphors is a promising approach for in situ monitoring of phosphate pollution in waterways and reservoirs. To date, the most sensitive phosphor developed for this purpose is Tb(cpboda)(DMF) 2 , where cpboda = (3,3'-((5-Carboxy-1,3-phenylene)bis(oxy))dibenzoic acid). In this study, we further improve this sensitivity by replacing the Tb 3+ ions with Eu 3+ ions to make Eu(cpboda)(DMF) 2 and find concentration-independent phosphate-sensitivity of 1570 ± 120, which is ≈8× more sensitive than the Tb-version. This improvement is attributed to Eu 3+ having a hypersensitive transition, while Tb 3+ does not. Additionally, we characterize the phosphor’s optical properties, photodegradation, and water solubility. We find that the phosphor presents challenges with regards to both photodegradation and solubility, as it is found to be poorly soluble in water and is quickly photodegraded under UV radiation <360 nm. However, these obstacles can, in theory, be overcome with the use of direct excitation of the Eu 3+ ions at 394 nm and careful design of an analysis instrument to reduce concentration variations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Aqueous phosphate detection using Eu(acac) 3

Currently, the majority of phosphate-sensitive phosphors reported in literature are metal-based complexes that require complicated and expensive synthesis to prepare. Here, in this study, we investigate the phosphate detecting capabilities of an inexpensive off-the-shelf phosphor: Eu(acac) 3 . We characterize its phosphate sensitivity as a function of sensor concentration and find that the quenching coefficient is inversely proportional to sensor concentration. This results in the limit-of-detection scaling linearly with sensor concentration. We determine its concentration-independent sensitivity to be 1.558 ± 0.012, which results in our lowest sensor concentration (44 μM) having a limit-of-detection of 3.39 ± 0.68 μM. We also find that for phosphate concentrations less than the sensor concentration, the fluorescence intensity ratio behaves linearly, but transitions to a non-linear functionality as the phosphate concentration exceeds the sensor concentration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a Portable In Situ Phosphorous Sensor

While phosphorus is a critical nutrient for all forms of life, runoff leads to phosphorus accumulation in surface water where it can cause a variety of health, environmental, and economic problems. The Department of Energy is interested in conducting long-term field experiments to monitor the impact of phosphorus in terrestrial and aquatic environments, and to better understand a cost vs. benefit analysis of reducing phosphorus pollution. Performing such long-term experiments requires affordable sensors capable of monitoring low-level phosphorus concentrations under challenging environmental conditions. However, such sensors are currently not available. The goal of this proposed project is to develop and demonstrate a low-cost portable phosphorus sensor suitable for in situ measurements. We will determine the technical requirements for a Raman-based sensor system, design and build a signal amplifier, integrate it with a Raman-based sensor, and demonstrate a proof-of-concept level sensor system. The expected accomplishments for Phase I include the identification of the technical requirements of a combined Raman laser/spectrometer and cavity enhancement system, building a proof-of-concept level sensor system capable of detecting orthophosphate compounds at the desired level of 0.25 mg P/L and organic P compounds, and verification of the sensor performance under laboratory and field conditions. In addition, we will identify initial hardening requirements that will need to be implemented during Phase II. While we plan to develop an integrated sensor system for monitoring phosphorus, the cavity-based enhancement system can also be used in combination with other (non-phosphorus) Raman sensors that we plan to develop or that are already commercially available. A recent market report highlights the increasing demand for such environmental monitoring applications, with the market for chemical detection anticipated to grow at a compound annual growth rate of 6.5% (2020-2025). Wide-spread monitoring of phosphorus could reduce the damage from eutrophication in freshwater, which is estimated to be $2.2 billion annually, thereby increasing biodiversity, reducing costs required for drinking water treatment, and decreasing economic losses related to recreation and angling and lake property values.

54 ENVIRONMENTAL SCIENCES↗