Search NASASearch

Engineering topics

Nawaz, Kashif

Publications and source records attributed to Nawaz, Kashif.

At least 19 records

Universal correlation for falling film evaporation heat transfer coefficients of water and seawater

Horizontal falling film evaporators are widely utilized in desalination industries to increase fresh water supply. However, universal correlations for seawater falling film evaporation under varied operational and geometrical conditions are simply unavailable in open literature. Thus, this study aims to develop such a universal correlation for both plain and enhanced tubes. The detailed heat transfer mechanisms are reviewed, and rational parameters are incorporated to develop the universal correlation. A dataset of 994 data points from 9 sources covering a wide range of conditions was compiled. These conditions include Reynolds numbers from 10 to 7235, heat fluxes from 7.7 to 208 kW/m -2 , saturation temperatures from 278 to 401 K, salinities from 0 to 60 gsalt kg -1 water, tube diameters from 15.8 to 50.8 mm, and liquid feeder height to diameter ratios from 1 to 2.25. Upon analysis, it was found that most of the recommended existing correlations exhibited poor predictive accuracy, as evidenced by larger MADs. The developed correlation in this study demonstrated the best predictive accuracy for the entire dataset, yielding a MAD of 16.8 % and an R 2 of 0.82. Furthermore, the performance of the new correlation was individually assessed across a broader spectrum of operational and design conditions, reflecting the individual conditions’ influences with an overall MAD of 20 %.

42 ENGINEERING

A methodology for selection of solid desiccants in energy recovery ventilators

Controlling indoor humidity levels is essential for maintaining acceptable indoor air quality in buildings. The use of energy recovery ventilators (ERVs) is an energy-efficient way to regulate indoor air humidity. Fixed-bed regenerators and rotary wheels are widely used ERVs because of their high sensible and latent effectiveness. These ERVs are made of desiccant-coated substrates, which enable them to transfer moisture between the supply and exhaust air streams. However, the moisture transfer ability of ERVs depends on the physiochemical and sorption properties of desiccants. Extensive, full-scale experiments are required to determine the best desiccant material for these systems. This paper presents a simplified method of selecting suitable desiccant materials for ERVs. The methodology involves important characterization methods, literature correlations for performance prediction, and cost-effective testing methods prior to full-scale testing, and full-scale test methods are discussed in detail. Furthermore, the performance of a few newly derived materials is evaluated and compared with that of conventional desiccants such as silica gel and molecular sieves. The highest latent effectiveness was obtained for composite of super absorbent polymer (SAP) with potassium formate (SAP-HCO2K-50 %), all-polymer porous solid desiccant (APPSD) and metal organic framework (MOF)–MIL–101 (Cr), followed by activated carbon fibre felt (ACFF) Silica sol-LiCl30, SAP, silica gel, MOF–303, and molecular sieve. Researchers and manufacturers would benefit from the proposed methodology and presented data in developing new desiccant materials for ERV applications.

Energy recovery

Corrosion Behavior of a Reactive Bond Between Stainless Steel and a Cast AlCeMg Alloy

Corrosion is a longstanding issue for metal components, especially those used in heat exchanger applications. Al–Ce–Mg alloys may provide a potential solution to this problem due to their good mechanical properties and potential reaction bonding with other metals. The reaction bonding involves a “reactive” bond that occurs upon casting of Al–Ce–Mg alloy over stainless steel (SS). Here this study examined the corrosion response of Al–2Ce–6Mg (atomic percent)/(SS) reactive bond interfaces after samples were completely submerged in nitric, sulfuric, formic, and mixed acids for 267 h. Scanning electron microscopy revealed that in the as-cut condition, reactive bond formations were seen frequently throughout the length of the casting and maintained a secure bond between the alloy and the SS tubes. Furthermore, the nitric, sulfuric, and the mixed acids did not have a deleterious effect on the reactive bond structure. However, formic acid did produce changes in both the microstructural appearance and the elemental profile across the bond due to the formation of corrosion reaction products on the acid-exposed surface.

36 MATERIALS SCIENCE

Demonstration of the carbon capture with building make-up air unit

Building-integrated carbon capture technology has the potential to reduce the cost of CO 2 capture while improving indoor air quality (IAQ). To promote the adoption of CO 2 capture in a building environment, this study investigated the possibility of integrating carbon capture technology with an existing rooftop make-up air unit (MAU) system to trap CO 2 . Here, in this study, a modular compact CO 2 capture system containing amine-functionalized polymer fibers was examined. The system, which was installed at the exhaust of the MAU, captures CO 2 before it leaves the building to enter the atmosphere as a greenhouse gas. The demonstrated average amount of CO 2 captured was 1.1–1.4 mmol/g of adsorbent material. Techno-economic analysis (TEA) was further performed on the CO 2 capture system, considering material costs, energy costs, as well as transportation and regeneration costs. These results were then used to estimate the levelized cost per ton CO 2 captured (LCOC). To achieve LCOC below $\$$100/t-CO 2 , adsorbents should have working capacities of 4.9 t and 3 t-CO 2 /year for 5 years and 10 years of operation, respectively. In summary, this study highlights a viable path toward the decarbonization of the commercial buildings sector and provides quantitative performance and economic insight on the suitability of building-integrated carbon capture technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Energy dataset of Frontier supercomputer for waste heat recovery

The Hewlett Packard Enterprise–Cray EX Frontier is the world’s first and fastest exascale supercomputer, hosted at the Oak Ridge Leadership Computing Facility in Tennessee, United States. Frontier is a significant electricity consumer, drawing 8–30 MW; this massive energy demand produces significant waste heat, requiring extensive cooling measures. Although harnessing this waste heat for campus heating is a sustainability goal at Oak Ridge National Laboratory (ORNL), the 30 °C–38 °C waste heat temperature poses compatibility issues with standard HVAC systems. Heat pump systems, prevalent in residential settings and some industries, can efficiently upgrade low-quality heat to usable energy for buildings. Thus, heat pump technology powered by renewable electricity offers an efficient, cost-effective solution for substantial waste heat recovery. However, a major challenge is the absence of benchmark data on high-performance computing (HPC) heat generation and waste heat profiles. This paper reports power demand and waste heat measurements from an ORNL HPC data centre, aiming to guide future research on optimizing waste heat recovery in large-scale data centres, especially those of HPC calibre.

97 MATHEMATICS AND COMPUTING

Flow maldistribution in plate heat exchangers – Impact, analysis, and solutions

Plate heat exchangers are commonly used in various industrial applications, such as refrigeration, air conditioning, heat pumps, powerplants, and chemical industries. Plate heat exchangers are well known for their superior heat transfer performance, compactness, and low refrigerant charge. Despite offering several advantages, they suffer from flow maldistribution issues. The flow maldistribution can deteriorate both the heat transfer and pressure drop performance, ultimately resulting in a lower system efficiency where plate heat exchangers are deployed. The flow maldistribution issues become more pronounced when the heat exchanger size is relatively large and the number of plates is higher, limiting the deployment of plate heat exchangers in larger industrial systems. Consequently, analyzing and understanding the flow maldistribution behavior in plate heat exchangers and finding ways to mitigate flow maldistribution related issues become essential topics of interest. Further, this review aims to address the effect of flow maldistribution on plate heat exchanger characteristics. First, the experimental and numerical works on flow maldistribution under single-phase and two-phase conditions are detailed. Subsequently, the end-channel and end-plate effects are discussed. Then, the methods to mitigate flow maldistribution in plate heat exchangers are outlined. Finally, based on a thorough literature survey and industrial requirements, future research directions are recommended.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

BTRIC Technical Support for Appalachia: FY 2024 Summary Report on Net Negative Carbon Building Demonstration with AgPod

This report investigates the effects of various concentrations of CO 2 on the photosynthesis and biomass accumulation of crops growing in an AgPod, using kale as the test crop. In the first year of the study, increasing the CO 2 concentration in the AgPod was found to promote higher photosynthetic rates in kale plants up to 1,300 ppm (the highest CO 2 concentration measured). An interesting finding was that net photosynthetic rates of kale leaves remain unsaturated until reaching unusually high levels of photosynthetically active radiation (PAR, > 1,200 µmol m -1 s -1 ) and CO 2 concentration (> 1,100 ppm). Such high levels of saturating PAR and CO 2 concentration values rarely occur under natural conditions, suggesting a promising potential for carbon capture via enriched controlled environment agriculture (ECEA). During the second year of the study, a second crop was planted to confirm the actual effects on growth with increased CO 2 concentrations. Our results suggest that growing kale plants in the AgPod system at higher CO 2 levels resulted in a successful and highly productive crop, up to three times the amount grown at 415 CO 2 . Further, the kale plants grown under higher CO 2 conditions (1000 ppm) are not CO 2 saturated and can potentially further improve yield at even higher CO 2 environments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

A Dynamic Model of Refrigerator with Thermal Energy Storage for Demand Flexibility

A refrigerator is an essential appliance for both commercial and residential applications. Thermal (Cold) energy storage can effectively reduce the carbon emission from refrigerators. This preliminary study investigated the demand flexibility of a domestic refrigerator using thermal (cold) energy storage through dynamic modeling and controls. The models include both fresh and frozen compartments, a vapor compression cycle loop, and thermal storage panels. Results show that thermal energy storage can effectively achieve temperature control of the compartments within the 4-hour time window. The load reduction and cost savings (46.3%) were achieved through the TES using TOU rates.

Gao, Zhiming

Al-Ce Alloy-Based Compact Heat Exchanger for Refrigerant Charge Reduction and Unprecedented Durability (CRADA NFE-21-08888 Final Report)

Oak Ridge National Laboratory and Eck Industries produced and characterized durable and corrosion resistant Al-Ce-Mg alloy-based heat exchanger. Eck Industries successfully casted Al-Ce-Mg heat exchanger. ORNL characterized reaction bonding between Al-2Ce-6Mg alloy and stainless-steel tube in a heat exchanger header. Metallurgical bonds were achieved between stainless steel tubes and Al-Ce-Mg alloy cast headers. ORNL performed corrosion testing on Al-Ce-Mg alloy/stainless steel tube reactive bond interface. In most cases no significant changes to the reactive bond morphology or compositional distribution were observed in the samples after exposure to acid for 267h acid.

36 MATERIALS SCIENCE

High performance heat exchangers for next generation hybrid cooler (CRADA NFE-19-07891 Final Report)

The evaporative cooling process has been successfully deployed in multiple energy conversion processes such as power generation, process cooling, heating, ventilation & cooling (HVAC), and commercial and industrial refrigeration. The heat exchanger is a very common yet extremely critical component of such systems. The device is important since the performance of the overall cooling system heavily relies on the thermal-hydraulic efficiency of the heat exchanger. The possible wet operation as evaporative cooling heat exchanger complicates the issue. Indeed, based on the hybrid nature of operation (fully dry, partially wet, fully wet) the efficiency can vary significantly and can cause performance variation for the whole system. Understanding the importance of the issue, Oak Ridge National Laboratory (Contractor) and Baltimore Aircoil Company (Participant) propose an activity focused on the analysis of the existing heat exchanger technology used in air and evaporative cooling processes and design, development and demonstration of a novel heat exchanger design based on porous materials. The potential candidates include metallic wire meshes and metal foams carefully designed for the proposed application. Prior research has indicated that these materials have great potential for deployment in thermal systems, particularly heat sinks and heat exchangers. It is expected that the successful completion of the project will lead to novel heat exchanger technology for hybrid systems (capable of dry and wet operation) by exploring newly emerging materials and their potential for heat transfer application. The overall goal is to develop a next generation heat exchanger technology which can be deployed in evaporative cooling systems. The impact of the such development is significant since, it will not only make the overall system highly efficient but will also, reduce the total refrigerant charge in the heat exchanger, a critical aspect for the deployment of refrigerants with lower Global Warming Potential (GWP).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Thermal shock resistance of additively manufactured alumina

The mechanical behavior and cracking patterns of thermally-shocked additively manufactured alumina were investigated. The flexural strength of test specimens that had been heated to temperatures ranging from 200°C to 1000°C and then rapidly quenched in water was determined at ambient temperature by four-point bending. Results indicated that the surface cracking patterns had a multifractal structure and that an increase in the thermal shock temperature led to an increase in the density and uniformity of the crack network. Further, the flexural strength results were analyzed with Weibull statistics, where the Weibull moduli for most of the thermal shock conditions tested were found to be statistically indistinguishable. It was also found that a significant decrease (~50%) in flexural strength occurred for heating temperatures ≥300°C. The effect of the manufacturing method on cracking patterns is discussed, as well as the implication of the material behavior for practical applications of these materials.

36 MATERIALS SCIENCE

Al-Ce Alloy-Based Compact Heat Exchanger for Refrigerant Charge Reduction and Unprecedented Durability

• Oak Ridge National Laboratory and Eck Industries produced and characterized durable and corrosion resistant Al-Ce-Mg alloy-based heat exchanger. • Eck Industries successfully casted Al-Ce-Mg heat exchanger. • ORNL characterized reaction bonding between Al-2Ce-6Mg alloy and stainless-steel tube in a heat exchanger header. • Metallurgical bonds were achieved between stainless steel tubes and Al-Ce-Mg alloy cast headers. • ORNL performed corrosion testing on Al-Ce-Mg alloy/stainless steel tube reactive bond interface. • In most cases no significant changes to the reactive bond morphology or compositional distribution were observed in the samples after exposure to acid for 267h acid.

36 MATERIALS SCIENCE

High performance heat exchangers for next generation hybrid cooler (CRADA Final Report)

The evaporative cooling process has been successfully deployed in multiple energy conversion processes such as power generation, process cooling, heating, ventilation & cooling (HVAC), and commercial and industrial refrigeration. The heat exchanger is a very common yet extremely critical component of such systems. The device is important since the performance of the overall cooling system heavily relies on the thermal-hydraulic efficiency of the heat exchanger. The possible wet operation as evaporative cooling heat exchanger complicates the issue. Indeed, based on the hybrid nature of operation (fully dry, partially wet, fully wet) the efficiency can vary significantly and can cause performance variation for the whole system. Understanding the importance of the issue, Oak Ridge National Laboratory (Contractor) and Baltimore Aircoil Company (Participant) propose an activity focused on the analysis of the existing heat exchanger technology used in air and evaporative cooling processes and design, development and demonstration of a novel heat exchanger design based on porous materials. The potential candidates include metallic wire meshes and metal foams carefully designed for the proposed application. Prior research has indicated that these materials have great potential for deployment in thermal systems, particularly heat sinks and heat exchangers. It is expected that the successful completion of the project will lead to novel heat exchanger technology for hybrid systems (capable of dry and wet operation) by exploring newly emerging materials and their potential for heat transfer application. The overall goal is to develop a next generation heat exchanger technology which can be deployed in evaporative cooling systems. The impact of the such development is significant since, it will not only make the overall system highly efficient but will also, reduce the total refrigerant charge in the heat exchanger, a critical aspect for the deployment of refrigerants with lower Global Warming Potential (GWP).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Material selection and manufacturing for high‐temperature heat exchangers: Review of state‐of‐the‐art development, opportunities, and challenges

Abstract Many energy systems demand heat transfer at high temperatures to keep up with high demand for power, so high‐temperature material that can perform and last under these harsh conditions is needed for heat exchangers. The engineering requirements for these high‐temperature heat exchanger material call for high thermal conductivity, high resistance to fracture, high resistance to creep deformation, environmental stability in environments associated with the application, and high modulus of elasticity while maintaining low cost to make and maintain. Naturally, ceramics are a good solution for this endeavor. In the past, high‐temperature heat exchangers made from ceramics have been used. We provide examples of ceramics in relevant heat exchange applications and provide motivation where additive manufacturing (AM) can improve efficiency. AM for the relevant material is under development, and we provide insight on the AM of ceramic materials and examples of AM heat exchangers keeping cost in mind. The motivation of the review paper is to provide a framework for material and manufacturing selection for high‐temperature heat exchangers for AM to keep up with the demand for better efficiency, better material, better manufacturing, and cost moving forward with AM technology in high‐temperature ceramic heat exchangers.

36 MATERIALS SCIENCE

A review of antimicrobial implications for improving indoor air quality

The frequent outbreak of infectious respiratory diseases, such as the recent COVID-19 epidemic, raised the importance of indoor air quality. Removing microorganisms from indoor air is critical to improve indoor air quality. Numerous studies in recent years have been published on developing antimicrobial materials and technologies for antibacterial and antiviral applications. Further, this study critically reviews the recent antimicrobial advances for improving indoor air quality. This paper provides a comprehensive analysis of the antimicrobial mechanisms, development of materials, and deployment strategies, as well as a performance evaluation of the antimicrobial implication for indoor air quality. Furthermore, the challenges and opportunities of future research directions are also highlighted.

59 BASIC BIOLOGICAL SCIENCES

Experimental Study on Flow Condensation of Low Global Warming Potential Refrigerants in a Micro-fin Aluminum Tube

This study investigates the dynamic shifts in refrigerant technologies driven by environmental regulations, particularly emphasizing low global warming potential (GWP). Moreover, there is a rising trend in the adoption of aluminum tubes with internal axial micro-fin structures in heat exchangers to reduce costs. The research focuses on the condensation process within an expanded axial micro-fin aluminum tube with a 5.96 mm fin-tip diameter. Various refrigerants are analyzed, including both single compounds (R-32, R-1234yf, R-1234ze(E)) and zeotropic mixtures (R-454B, R-454C, R-455A). Experimental procedures cover a range of condensation temperatures (35~45 °C), reduced pressures (0.21~0.55), and mass fluxes (150~350 kg/(m² s)), providing crucial data on heat transfer coefficients (HTC) and frictional pressure gradient (FPG). This data is particularly significant for high-glide refrigerants and is instrumental in the design of advanced air conditioning and refrigeration systems aimed at mitigating global warming.

Hu, Yifeng

Modeling and Analysis of a Heat Pump Clothes Dryer with Thermal Energy Storage

Clothes drying is an energy-intensive process that causes significant electricity consumption and carbon emissions in the US. Approximately 83% of Households in the US own a tumble clothes dryer at home and 80% of dryers are electrical resistance dryers with low energy efficiency. Heat pump technology makes it possible for highly efficient and clean drying. Additionally, the ventless design of heat pump clothes dryers (HPCD) provides more installation flexibility. HPCD involves three primary mediums: wet clothes, a closed air loop, and a refrigerant circuit. The evaporator is used to dehumidify the wet air and the condenser is used to re-heat the dry air. One of the critical technological barriers to HPCD market penetration is its long drying time, primarily due to the relatively low discharging temperature and the slow response during the warm-up period. In this study, the thermal energy storage (TES) technology is adopted to address this challenge by providing pre-heating of air prior to the condenser to increase the operating temperature of the process air. The heat pump will charge the phase change material (PCM) in the TES device with heating energy during clothes washing and the PCM will discharge the stored heat to facilitate air heating during clothes drying. To analyze the optimal design and potential for energy saving and drying time reduction, a mathematical model of the HPCD system was developed. The HPCD is a highly dynamic system with a coupled heat and mass transfer and heat pumping cycle. This paper provides solutions to simulate the transient behavior of the system while maintaining low computational cost. The modeling result indicates reduced energy consumption and drying time by integrating TES with HPCD, as compared to electrical resistance dryers. The study can provide significant insights into improving building flexibility with TES and smart appliances.

Liu, Xiaoli