Search NASA⌕ Search

Engineering topics

Nawaz, Kashif

Publications and source records attributed to Nawaz, Kashif.

At least 145 records · Page 8

Experiment and non-local crystal plasticity finite element study of nanoindentation on Al-8Ce-10Mg alloy

Cerium and magnesium strengthened aluminum alloys, or Al-Ce-Mg, is a recently developed alloy family that exhibits good mechanical properties at elevated temperatures (~300 °C). To examine the single-crystal properties of Al-Ce-Mg alloys, nanoindentation experiments are conducted in this study. A crystal plasticity finite element model (CPFEM) with the evolution of geometrically necessary dislocations (GNDs) is applied to simulate the indentation in individual grains. A parametric study is carried out to investigate the sensitivity of each crystal plasticity model parameter to the indentation behavior. The highly sensitive parameters are calibrated by matching the indentation load-depth curves, while the rest parameters are obtained from bulk polycrystal uniaxial tension tests. Overall, satisfactory matching between experiment and simulation is obtained for each individual grain. The calculated hardness, as determined from the experiment, shows the dependence on indent depth, which is captured by the GND model. Furthermore, the effect of grain orientation and neighboring grains to nanoindentation behavior have been discussed with the comparison between the simulation and experiments.

36 MATERIALS SCIENCE↗

Critical review and future prospects for desiccant coated heat exchangers: Materials, design, and manufacturing

Solid desiccant dehumidification is a promising alternative to vapor compression-based air-dehumidification to reduce energy consumption and improve air quality. Desiccant coated heat exchanger (DCHE), as one type of solid desiccant dehumidification system, can improve system performance and efficiency. The thermal performance and moisture removal capability of the DCHE greatly influence its dehumidification performance.The present work aims to critically analyze the designs, materials, and manufacturing methods of heat exchangers used for solid desiccant coating and look into recent developments in regular heat exchangers, potentially deployed as a substrate for DCHE applications. A comprehensive literature review of publications regarding solid desiccant materials, heat exchangers, manufacturing and coating methods, binder materials, and the performance of heat exchangers has been developed. Alternative heat exchangers are described as better options than fin and tube heat exchangers that have been considered thus far for DCHE applications. Additionally, the heat exchanger's manufacturing process and materials over their thermal and mass exchange performance have been analyzed. Despite the widespread use of fin and tube heat exchangers for solid desiccant coating, recent developments in heat exchanger design, and related fields such as manufacturing methods and materials, open the possibilities for their application in solid desiccant dehumidification systems. Lastly, the authors provide their outlook on possible developments of DCHE technology, aiming to increase systems' energy and dehumidification performance.

36 MATERIALS SCIENCE↗

Theoretical Analysis of a Single-Stage Gas-fired Ejector Heat Pump Water Heater

Ejector-driven systems have the ability to operate at high efficiencies, utilizing recycled thermal energy as a power source. For a typical ejector heat pump (EHP) system, the increase of the condenser temperature reduces the coefficient of performance (COP). In addition, if the condenser temperature is higher than the critical temperature, the ejector may not function. In this situation, the condenser temperature must be reduced, and an additional heater will be utilized to heat the production water from the condenser temperature to the desired temperature. In this study, a single-stage gas-fired EHP is investigated and thermodynamically modeled to optimize the system COP for the purpose of heating water by utilizing the thermal energy from the ambient air. The effects of the high-temperature evaporator (HTE) and low-temperature evaporator (LTE) on the ejector critical back pressure and the EHP system performance are examined for a HTE temperature range of 120–180 °C and LTE temperatures of 15.5, 17.5, and 19.5 °C. Our results show that an optimized COP for the EHP system exists and is dependent on HTE and LTE temperatures and the primary nozzle throat diameter. In addition, it is found that the peak EHP COP does not necessarily coincide with a large ejector COP. From this study, a maximum EHP COP of 1.31 is achieved at a HTE temperature of 170 °C and LTE temperature of 19.5 °C with a total heating capacity of 15.98 kW.

42 ENGINEERING↗

Developing an experimental-computational framework to investigate the deformation mechanisms and mechanical properties of Al-8Ce-10Mg alloys at micro and macroscales

There is a promising future for the use of aluminum-cerium-magnesium alloys in a broad range of applications, including devices that operate at high temperatures. With cerium currently considered a waste product of rare earth mining validation studies of possible applications are essential to reduce the environmental waste. Here, a computational-experimental framework is developed to investigate the role both the intermetallic and matrix have on the mechanical properties of these alloys. A set of experiments, including SEM/EBSD imaging, nanoindentation, in-situ SEM tensile testing, and in-situ SEM-DIC tests are performed to characterize the microstructure and mechanical properties of these alloys. Furthermore, the elastic, plastic, and failure deformation mechanisms of the microstructure, and their correlation with the bulk scale mechanical properties are investigated. Experimental results are also used to calibrate parameters for a crystal plasticity finite element model, by performing a computational framework that minimizes the error between the computational and experimental results. This model is then utilized to investigate how the area percentage of intermetallics and the crystallographic texture control the mechanical properties of the alloy. Simulation results show that an increase in the percentage of intermetallics increase the strength but decrease the ductility of the alloy. Also, a change in material texture improves strength and reduces damage that leads to material failure. The development of the crystal plasticity model, as discussed in this work, opens opportunities for future investigations of similar aluminum-cerium-magnesium alloys.

36 MATERIALS SCIENCE↗

Nondimensional convection numbers modeling thermally stratified storage tanks: Richardson's number and hot-water tanks

Thermally stratified storage tank studies have spanned over 50 years to increase the thermal storage efficiency and accurate prediction of the outlet temperature particularly for solar applications. The studies have reviewed and modeled the jet and plume flow phenomena inside the tank due to the inlet mixing and stratification level. Kelvin–Helmholtz and Rayleigh–Taylor instabilities are the major drivers of the mixing in these tanks. Momentum jets deflecting off walls at the bottom of the tank also create significant mixing. Reviewing Richardson models shows that the categorization was based on the range of Reynolds numbers at the inlet. Unfortunately, the use of superficial velocity in calculating the Richardson number results in critical values in the literature ranging from below 0.25 to 100. The most used length scale associated with these flows is an inertial scale based on the tank height or diameter although the mixing can occur at a relatively smaller scale. The various inlet devices and a large span of flow rates experienced in thermally stratified storage tanks requisite the use of the Reynolds number in combination with a convection number for accurate one dimensional models that predict performance over the long-term. The evaluation of peak shifting of electric loads leveraging renewable sources for applications, including residential hot-water tanks, commercial water tanks, and large-scale chilled water storage tanks, require these models. Finally, this paper is focused on establishing the significance of the convection numbers in conjunction with the Reynolds number for modeling the thermal stratification in storage tanks.

14 SOLAR ENERGY↗

Analysis of basic airflow configurations for separate sensible and latent cooling systems with indoor air recirculation

Separate sensible and latent cooling (SSLC) is a technology with efficiency and comfort advantages over conventional cooling systems used for space conditioning of buildings. Using multiple cooling processes at different temperatures allows SSLC to save energy by raising the evaporation temperature of the sensible cooling process. In this paper, all possible airflow configurations of SSLC systems are enumerated under the following constraints: exactly two heat exchangers are used, and air is recirculated to the conditioned space (no exhaust or outdoor air treatment). Seven designs are identified, with varying free operating variables, and each is modeled. Analysis reveals that several configurations are equivalent, and there is only one unique basic airflow SSLC configuration: the one with the sensible and latent heat exchangers placed in series. The efficiency of the SSLC system is compared against that of the conventional system. Under standard conditions, an SSLC system can improve the coefficient of performance by 14.8%. In addition to the numerical simulation, the optimal operating condition of the basic air configuration of the SSLC system is derived analytically. The basic SSLC system is shown to offer the highest performance improvement when the outdoor temperature is relatively cool and the space sensible heat ratio is high.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Parametric Studies of Heat Pump Water Heater Using Low GWP Refrigerants

A storage heat pump water heater (HPWH) comprises a vapor compression system and a hot water tank. It can lead to more than 70% energy saving, compared with electric resistance heating. HPWH usually uses a wrapped-tank coil as the water heater. The wrapped coil has a strong interaction with the water tank and impose a new challenge for the engineering design and simulation study. Based on the US DOE/ORNL Heat Pump Design Model (HPDM), i.e., a public-domain, component-based thermal system modelling platform, a segment-to-segment wrapped-tank coil model coupled with a one-dimensional stratified water tank model were developed, which facilitates modeling and design HPWHs having various configurations and components. Additionally, the hardware-based design model was used to evaluate refrigerants having lower global warming potentials to replace R-134a, including R-1234yf, R-1234ze, R-290, R-513A and R-450A, when effects of compressor size, refrigerant charge on 24-hour uniform energy factor (UEF) and first-hour rating (FHR) were investigated.In the drop-in replacements, R-1234ze achieved the best UEF, and R-290 resulted in the lowest UEF. When downsizing the compressor to maximize the UEFs, the UEFs of R-134a, R-290, R1234yf, R-450A and R-513A ascended to the range of 4.4 to 4.53, with R-513A having the highest UEF. The R-1234ze ended up having the lowest UEF of 4.27. Refrigerants having larger volumetric vaporization heat led to higher FHRs if using the fixed-size compressor, that R-290 resulted in the highest FHR.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling of crystallization fouling on a horizontal-tube falling-film evaporator for thermal desalination

Scale formation within horizontal-tube falling-film evaporators is an important issue for thermal desalination, because of the deterioration of heat transfer performance and added maintenance costs. Predicting the fouling process is crucial for desalination plant design, operation, and maintenance. In this paper, a model is developed to predict the crystallization fouling process during seawater falling-film flow over a horizontal tube bundle. The scaling is estimated based on deposition theory, with couple heat transfer including the in-tube steam condensation, conduction through the tube wall and the scale layer, and falling-film evaporation. The spatial and temporal variations of temperature, heat transfer coefficient, and scale thickness are predicted, and the effects of variations in process parameters of steam, feed seawater, and tube properties on the scale thickness, evaporation rate, and heat transfer coefficient for falling-film evaporation are analyzed. Comparisons to existing experimental data show the scaling layer thickness falls in the general range of reported measurements, with a slight overestimation due to neglecting the delay of scaling onset under real conditions. The scale layer thickness increases dramatically as the in-tube steam pressure is increased or the seawater flow rate is decreased. In general, the scaling layer becomes thicker on the lower tubes in the tube bundle, due to the heat and mass transfer of the falling film. The effect of tube material on scaling appears mainly dependent on thermal conductivity; thus, using polymer rather than a stainless steel tube decreases scaling and evaporation rate 96% and 88%, respectively. Finally, this work has potential to guide thermal desalination plant design, material selection, and operating parameter optimization.

42 ENGINEERING↗

Structural, Thermal, and Mechanical Characterization of a Thermally Conductive Polymer Composite for Heat Exchanger Applications

Polymer composites are being considered for numerous thermal applications because of their inherent benefits, such as light weight, corrosion resistance, and reduced cost. In this work, the microstructural, thermal, and mechanical properties of a 3D printed polymer composite with high thermal conductivity are examined using multiple characterization techniques. Infrared spectroscopy and X-ray diffraction reveal that the composite contains a polyphenylene sulfide matrix with graphitic fillers, which is responsible for the high thermal conductivity. Furthermore, differential scanning calorimetry determines that the glass transition and melting point of the composite are 87.6 °C and 285.6 °C, respectively. Thermogravimetric analysis reveals that the composite is thermally stable up to ~400 °C. Creep tests are performed at different isotherms to evaluate the long-term performance of the composite. The creep result indicates that the composite can maintain mechanical integrity when used below its glass transition temperature. Nanoindentation tests reveal that modulus and hardness of the composite is not significantly influenced by heating or creep conditions. These findings indicate that the composite is potentially suitable for heat exchanger applications.

36 MATERIALS SCIENCE↗

Properties of SiC-Si made via binder jet 3D printing of SiC powder, carbon addition, and silicon melt infiltration

In this work, we report the physical and mechanical properties of ceramic composite materials fabricated by binder jet 3D printing (BJ3DP) with silicon carbide (SiC) powders, followed by phenolic resin infiltration and pyrolysis (IP) to generate carbon, and a final reactive silicon melt infiltration step. After two phenolic resin infiltration and pyrolysis cycles; porosity was less than 2%, Young's modulus was close to 300 GPa, and the flexural strength was 517.6 ± 24.8 MPa. However, diminishing returns were obtained after more than two phenolic resin infiltration and pyrolysis cycles as surface pores in carbon were closed upon the formation of SiC, resulting in reaction choking and residual-free carbon and porosity. The instantaneous coefficient of thermal expansion of the composite was found to be independent of the number of phenolic IP cycles and had values of between 4.2 and 5.0 ppm/°C between 300 and 100°C, whereas the thermal conductivity was found to have a weak dependence on the number of phenolic IP cycles. While the manufacturing procedures described here yielded highly dense, gas impermeable, siliconized SiC composites with properties comparable to those of bulk siliconized silicon carbide processed according to conventional techniques, BJ3DP enables the manufacture of objects with complex shape, unlike conventional techniques.

36 MATERIALS SCIENCE↗

A Flow Rate Dependent 1D Model for Thermally Stratified Hot-Water Energy Storage

Stratified tank models are used to simulate thermal storage in applications such as residential or commercial hot-water storage tanks, chilled-water storage tanks, and solar thermal systems. The energy efficiency of these applications relates to the system components and the level of stratification maintained during various flow events in the tank. One-dimensional (1D) models are used in building energy simulations because of the short computation time but often do not include flow-rate dependent mixing. The accuracy of 1D models for plug flow, plug flow with axial conduction, and two convection eddy-diffusivity models were compared with experimental data sets for discharging a 50-gal residential tank and recharging the tank with hot water from an external hot-water source. A minimum and maximum relationship for the eddy diffusivity factor were found at Re <2100 and >10,000 for recirculation of hot water to the top of the tank and vertical tubes inletting cold water at the bottom. The root mean square error decreased from >4 °C to near 2 °C when considering flow-based mixing models during heating, while the exponential decay of the eddy diffusion results in a root mean square error reduction of 1 °C for cone-shaped diffusers that begin to relaminarize flow at the inlet.

1D flow model↗

Thermodynamic Analysis of Thermo-vacuum Clothes Drying Operation

Clothes drying accounts for a significant amount of energy consumed in residential and commercial sectors. A thermal vacuum clothes drying technology (TVCD) is proposed as an advanced clothes dryer which can significantly reduce the energy requirements by expediting the drying process. In the conventional convective clothes dryer, hot dry air is introduced into the drum which gets in direct contact to dry the clothes. This process is energy inefficient since the significant amount of heat and the water carried out with the exhaust stream are wasted. In contrast to the conventional convective drying technique, the drying mechanism of TVCD is through nucleate boiling at low temperature due to reduced vessel pressure. The process is not only efficient but also reduces the required time for drying. The objective of this paper is to develop a comprehensive thermodynamic model to predict the transient drying process of TVCD. The three-stage system model including the detail analysis of individual components is capable of simulating the variation of the water content in the textile under various operational conditions. The preliminary results show that the drying time of 3 lb textile from 70% to 2.5% in TVCD is approximately four times less than the time required in the conventional clothes dryer. Parametric studies are carried out to understand the effect of operation conditions and component geometry on the system performance. Energy consumption of the system is also analyzed.

Yang, Cheng-Min↗

Heat Transfer and Pressure Drop Characteristics of Water Flow Boiling in Internally Enhanced Tubes

Flow boiling is a critical process for many thermal conversion processes such as HVAC&R, water heating, power generation and desalination applications. The major goal of this paper is to enhance the in-tube heat transfer for flow boiling of water and further improve the efficiency of the boiler. This paper presents an experimental investigation of the heat transfer and pressure drop characteristics for water under forced convection and boiling conditions inside both smooth and enhanced tubes. The results in the smooth copper tube are compared with several correlations and used as a baseline. The two-phase heat transfer and pressure drop performance of the water flow boiling in the internally enhanced tube is investigated, and the influence of internal surface pattern on the thermal characteristics is discussed. The relations of the heat transfer coefficient with mass flux, heat flux and vapor quality are analyzed according to the results.

Yang, Cheng-Min↗

A Numerical Analysis of The Pool Boiling Process in Flooded Evaporators Using Different Refrigerants

The pool boiling process can be observed in several energy conversion processes including commercial and industrial refrigeration, industrial air-cooling operations, and power generation. The process becomes more involved when pool boiling in a tube bundle is considered. In the current study, a numerical model is developed to predict the key performance parameters of a flooded evaporator while considering a range of working fluids. A kettle reboiler configuration was considered, and a performance model was developed to account for boiling on individual tubes, merging of vapor bubbles, and movement under gravity. A volume of fluid (VOF) model was used to deal with the different phases in the simulation. Various fluids were considered in this study including HFE-7000, HFE-7300, and water. The trajectories of the bubbles were tracked, and the resulting information has been summarized in physical measurable quantities.

Zhang, Mingkan↗

Gas-Phase Temperature Mapping of Evaporating Microdroplets

Evaporation is a ubiquitous and complex phenomenon of importance to many natural and industrial systems. Evaporation occurs when molecules near the free interface overcome intermolecular attractions with the bulk liquid. As molecules escape the liquid phase, heat is removed, causing evaporative cooling. The influence of evaporative cooling on inducing a temperature difference with the surrounding atmosphere as well as within the liquid is poorly understood. Here, we develop a technique to overcome past difficulties encountered during the study of heterogeneous droplet evaporation by coupling a piezo-driven droplet generation mechanism to a controlled micro-thermocouple to probe microdroplet evaporation. The technique allowed us to probe the gas-phase temperature distribution using a micro-thermocouple (50 μm) in the vicinity of the liquid–vapor interface with high spatial (±10 μm) and temporal (±100 ms) resolution. We experimentally map the temperature gradient formed surrounding sessile water droplets having varying curvature dictated by the apparent advancing contact angle (100° ≲ θ ≲ 165°). The experiments were carried out at temperatures below and above ambient for a range of fixed droplet radii (130 μm ≲ R ≲ 330 μm). Our results provide a primary validation of the centuries-old theoretical framework underpinning heterogeneous droplet evaporation mediated by the working fluid, substrate, and gas thermophysical properties, droplet apparent contact angle, and droplet size. We show that microscale droplets residing on low-thermal-conductivity substrates such as glass absorb up to 8× more heat from the surrounding gas compared to droplets residing on high-thermal-conductivity substrates such as copper. Finally, our work not only develops an experimental understanding of the heat transfer mechanisms governing droplet evaporation but also presents a powerful platform for the study and characterization of liquid–vapor transport at curved interfaces wetting and nonwetting advanced functional surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pressure Exchanger for Energy Recovery in a Trans-Critical CO2 Refrigeration System

Trans-critical CO2 vapor compression (VC) refrigeration cycles require a high compression ratio, which is associated with high expansion losses. To recover these expansion losses, a pressure exchange process between the low- and high-pressure sides of the VC cycle is proposed and examined in this study. The proposed pressure exchange system is an open type constant volume process where the high- and low-pressure flows mix inside the system. This prototype is inspired by the pressure exchangers used in reverse-osmosis (RO) desalination systems. In this system, a 2D model was generated and modeled using the computational fluid dynamics (CFD) technique. The numerical model ignored any losses due to leakage or hydraulic friction and the process is considered adiabatic. For the modeling, it was assumed that the inlet conditions for the two pressure exchanger flows are similar to the flow conditions at the evaporator and gas cooler outlets in a VC cycle. Two parameters are examined to test the validity of the system and understand their effect on the performance, including the inlet flow rate represented by the inlet velocity and the process time represented by the speed of rotation. A total of nine cases were simulated and analyzed in this study.

30 DIRECT ENERGY CONVERSION↗

Separate sensible and latent cooling: Carnot limits and system taxonomy

Energy efficiency and thermal comfort can be improved by independent control of temperature and humidity. In recent work, an emerging class of cooling systems known as separate sensible and latent cooling (SSLC) systems have demonstrated 14 to 47% energy savings, while simultaneously providing better comfort control than conventional air conditioning. In this work, SSLC is defined as using two or more cooling processes with unequal sensible heat ratio (SHR) to control temperature and humidity independently and dynamically. Fundamental efficiency limits of SSLC systems are developed for the first time, demonstrating that the Carnot efficiency for SSLC is higher than that of conventional systems. It is revealed that SSLC has particularly high potential for moderate outdoor temperatures, high sensible building loads, and drier indoor conditions. Additionally, this work proposes a classification scheme for SSLC systems, revealing an enormous number of feasible cycle permutations. This provides a framework for the important research task of developing SSLC systems that will save energy, be practical to construct, and be controllable.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗