Flexible Transformers for Resilient and Adaptable Power Systems

This paper presents experience with grid ready flexible transformer unit, which is in service for two years without any difficulty. Transformer unit is capable of changing short circuit impedance on load and it is equipped with state-of-the-art monitoring system.

field validation↗

Advanced Flexible Transformers

Advanced grid solutions are comprised of advanced transmission technologies and grid enhancing technologies. In this webinar, experts will provide participants with insights into eight advanced grid solutions. The advanced transmission technologies that will be discussed include point-to-point high voltage direct current and advanced conductoring and the grid enhancing technologies that experts will explore include topology optimization, advanced power flow control, dynamic line rating, energy storage, virtual power plants, and advanced flexible transformers

flexible power transformer, power flow controller,↗

FLEXIBLE POWER TRANSFORMERS TO IMPROVE RESILIENCY OF TRANSMISSION NETWORKS

For decades, transformer flexibility of operation has been limited to adjustable voltage ratio and, in some cases, several ratings with staged cooling. Transformers reconnectable to multiple voltage ratings have been primarily applied as emergency replacements. Other versions of “flexible transformers” were developed for continuous, long-term operation at specific sites, with application limited to large utilities. A new technology that supports today’s power systems adaptability requirements has been developed to provide not only voltage and power rating flexibility, but also an adjustable short-circuit impedance. This last, unique feature allows for a closer match to actual system operational requirements and could be used in the future to enhance resiliency and improve dynamic control of electrical grids. While the solution’s fundamentals have already been introduced in several technical forums, the intention of this article is to focus on the potential benefits of this new type of transformer and share the deployment experience of a full-scale prototype that has been in operation in a major U.S. utility since 2021

flexible transformer, resilient grid, variable lea↗

Decomposition characteristics of C4F7N-based SF6-alternative gas mixtures

C4F7N [2,3,3,3-tetrafluoro-2-(trifluoromethyl)propanenitrile]/CO2 gas mixtures are being developed as an eco-friendly electrical insulator to replace SF6, the most potent greenhouse industrial gaseous dielectric. However, recent studies have reported complicated and often conflicting decomposition pathways for C4F7N/CO2 gas mixtures, which has raised concerns. In this work, the decomposition characteristics of C4F7N/CO2 gas mixtures were studied comprehensively by both designed computations and experiments. Computations were performed starting from fundamental propositions of C4F7N/CO2 decompositions, which were further experimentally verified by pyrolysis, long-term thermal aging with/without catalytic materials (industrial-grade molecular sieves 4A), and electrical decomposition by spark discharge. The results of both computations and experiments suggest that in an ideal thermal decomposition, C4F7N is likely to decompose into C2F6 and small fluoronitriles first at high temperatures. The generation of C3F6 and C2N2 from C4F7N thermal decomposition at lower temperatures appears because of the catalytic effect of incompatible materials, for example, the industrial-grade molecular sieves 4A that we tested. The electron impact dissociation of C4F7N plays an important role in C4F7N electrical decomposition, leading to additional formation of distinctive small molecules of CF4 and C2N2 of low concentrations. It was pointed out based on a real arcing test in a load disconnector that the decomposition of C4F7N gas mixtures in real applications will be at a much moderate and manageable rate than what was obtained from the highly accelerated laboratory tests presented in this work. The signatures of decomposition products extracted in this study provide invaluable guidance for developing decomposition-based diagnosis and fixation of decomposition byproducts toward SF6-free power grids.

Physics↗

Flexible transformer system

A system includes conductive windings extending around a magnetic core and impedance-varying windings extending around the magnetic core. The impedance-varying windings include positive windings and negative windings. The conductive windings and the impedance-varying windings conduct electric current around the magnetic core. The system includes a first impedance tap changer that is electrically coupled with the positive windings of the impedance-varying windings and a second impedance tap changer electrically coupled with the negative windings of the impedance-varying windings. A controller controls the first impedance tap changer and the second impedance tap changer to change an impedance of the system by changing which portion of the positive windings and which portion of the negative windings are conductively coupled with the conductive windings, and which portion of the positive windings and which portion of the negative windings are disconnected from the conductive windings.

Ndiaye, Ibrahima↗

Grid-Ready Flexible Transformers for Resilient Transmission Networks

Today’s transmission networks extend for hundreds of kilometers, transferring significant amounts of electrical energy. For every country, there are sort of “back- bone” lines, where a massive failure of transformers would create serious challenges to sustain a reliable energy supply. Natural phenomena and human driven actions could be triggers of such catastrophic events. For large utilities, or groups of utilities, it would be highly convenient to count with “flexible transformers”, which could be used as replacements for different voltage levels and with impedance adjustable to match optimum local requirements of impacted substations. Currently applied “emergency transformers” are fixed-impedance devices. In this contribution, a new concept of flexible, “future-grid ready” type of power transformers, specially devised for transmission networks is explained. This transformer has adjustable impedance features, which could be on-line operated. The concept has been proven to be functional and stable in the factory lab and in the field, by means of a prototype autotransformer of of 100 MVA, 165/69 Kv.

impedance of transformers↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

As we know, power transformers are the most critical asset of the transmission network. Although highly reliable, they still can fail prematurely or ultimately retire at the end of their service life. In today’s design practices, transformers are tailored to their specific application and therefore cannot replace each other unless identical. Additionally, they provide minimal support to the grid operation and therefore limit the grid flexibility and resiliency when facing severe conditions. In this presentation, we will introduce the concept of flexible power transformer and demonstrate how one single unit can serve as a spare to multiple units in a given fleet, allow to control the power flow between transformers or lines operating in parallel and ultimately be used to limit subsequent faults in transmission lines. We will also introduce the world’s first prototype in operation, a 60MVA, 165kV flexible autotransformer.

flexible power transformer, autotransformer, varia↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sensitivity analysis of the technical and economic feasibility of converter-interfaced CHP System

The adoption of small-to-medium sized (1MW~20MW) combined heat and power (CHP) system is lagging, especially in industrial and commercial applications. Our prior research has proved that interfacing CHP with grid-ready converters can increase its economic value and technical benefits; this paper is focused on investigating the critical parameters impacting profitability of converter-interfaced CHP, including CHP sizing scenario, energy price, generator cost, converter cost, voltage support price, converter to engine size ratio and interconnection delay. An automatic toolkit for evaluating CHP return on investment (ROI) is developed to enhance the computation capability and efficiency. Based on varying the value of critical parameters, 975 use cases are analyzed. Results show that the profitability of converter-interfaced CHP over directly-coupled CHP is more sensitive to energy price, delays in interconnection process, converter cost and much less to generator cost or voltage support price.

converter, CHP, ROI, economic feasibility, sensiti↗

Transformer system

A flexible transformer system includes conductive windings extending around a magnetic core of a transformer phase and impedance-varying windings extending around the magnetic core of the transformer phase. The conductive windings and the impedance-varying windings are configured to conduct electric current around the magnetic core of the transformer phase. The system includes an impedance switch coupled with the impedance-varying windings and with the conductive windings. The impedance switch is configured to change an impedance of the system by changing which impedance-varying winding of the impedance-varying windings is conductively coupled with the conductive windings and which impedance-varying winding of the impedance-varying windings is disconnected from the conductive windings.

Premerlani, William James↗

Harmonics and Stability Evaluation of Converter-Interfaced Combined Heat and Power Units

Grid integration of medium-sized combined heat and power (CHP) units is challenging due to strict grid codes and conventional generators lack of control flexibility to meet these grid codes. Adding a two-stage ac-dc-ac power electronics interface between the generator and the utility grid will accelerate the interconnection process of CHP units. For the dc-ac stage, a voltage source converter (VSC) has been widely used as a grid-tied inverter because of its fast control and low total harmonics distortion (THD). In this paper, several topologies of generator-side rectifiers for ac-dc power conversion are explored and analyzed. The harmonics impact of various rectifiers on the CHP generator are evaluated. The overall cost of the electrical system, when using various types of rectifiers, is assessed and the VSC back-to-back converter interface configuration is found to be optimal. The overall system stability is also examined using small-signal impedance analysis to assess potential instability issues at the system level.

CHP, Harmonics, Generator Rectifier Unit, DC Imped↗

Integration Study of Converter-Interfaced Combined Heat and Power Plants

Combined Heat and Power (CHP) systems, as a proven technology, provide numerous benefits to the plant owner by saving electricity bill, reducing carbon dioxide emissions, and improving electricity service reliability. However, their integration into the distribution grid faces many barriers including the complexity of grid code requirements and the lack of technical expertise in commercial and small industrial plants to interface with the utility and accelerate the interconnection process. To solve these issues, this study proposes a converter-interfaced solution for CHP integration. Simulations including various fault scenarios and load flow under different grid conditions are carried out to compare technical performances of the proposed solution with directly-coupled CHP. Results show that the generator size of converter-interfaced CHP can be reduced by approximately 25% and it also provides advantageous features such as reduced stress level under fault conditions and a better dynamic stability margin. In addition, a power factor controller is designed and reactive power from CHP is dispatched in such a way that the CHP plant is compliant with power factor requirements from utilities under all operating conditions.

Converter, Combined heat and power, Distributed en↗

Feasibility Analysis of Converter-Interfaced Combined Heat and Power System

As a promising new design concept, the converter-interfaced combined heat and power (CHP) system is coupled to the bulk grid through a rectifier and a grid-ready tied inverter. Compared to the traditional directly-coupled CHP system, it removes the requirement for oversizing the CHP generator, limits the short-circuit contribution of the generator and simplifies the grid integration process of CHP system. This paper evaluates the economic benefits of this concept by calculating the annualized Return-on-Investment (ROI) and comparing it to the directly-coupled system. The economic analysis includes timeseries simulations to compute energy transactions with the bulk grid as well as sizing the equipment to calculate the capital and operational costs. Obtained results indicate that in majority of user cases evaluated, the converter-interfaced CHP systems can provide better ROI than directly-coupled systems. Given the additional technical benefits provided by inverter-based distributed energy resources (DERs), the proposed concept is proved to be technically viable and economically feasible.

03 NATURAL GAS↗

Grid Ready, Flexible Large Power Transformer

GE Research and its partner Prolec GE have proposed a novel and breakthrough concept to improve the flexibility and interchangeability of large power transformers (LPTs). LPTs refer in this report to transformers with a power rating equal or greater than 100 MVA. The concept consists of a 3-phase autotransformer bank having one specified high voltage side (HV) voltage and three configurable low voltage side (LV) voltage taps. Moreover, the leakage impedance is adjustable offline using taps which allows to accommodate short-circuit requirements for a wide range of LPTs applications. The research performed aimed to develop and validate a cost-effective design of a flexible LPT and to demonstrate its competitiveness with the LPT fleet currently in operation in the U.S. The concept is intended for the long-term replacement of existing LPTs. In this project, the U.S based population of LPTs was analyzed to determine their commonality in power, voltage classes, and impedance range. Up to 9,700 units, currently deployed in the NERC’s Eastern and Western interconnection regions, were evaluated. This analysis yielded the specifications of two flexible LPTs to be designed to demonstrate the manufacturability and competitiveness of the concept: a 345 kV, 230 MVA and a 230 kV, 100 MVA LPTs. The two LPTs are both configurable to 161 kV, 138 kV, and 115 kV on the LV side and allow leakage impedance variation between 4% and 14%. The design output showed that the flexible LPT is manufacturable and competitive with conventional LPT. The proposed design has a power efficiency of 99.5% and a total active part weight increase ranging only between 15% and 28% relative to conventional LPTs it can be substituted with. Indeed, for the flexible LPT, the higher the LV side voltage is, the higher is its power rating. Hence, flexible LPTs are more competitive when compared with the largest conventional LPT they can replace. Power systems analyses were carried out to evaluate the performance of the flexible LPT when replacing an existing conventional LPT. These analyses showed that short-circuit and inrush currents will remain respectively within 15% and 9.4% of their original levels suggesting that no substations equipment is likely to be replaced due the installation of the flexible LPT. In addition, the analyses showed that the transient overvoltage anticipated at the impedance configuration switch will be manageable and will not pose any particular risk during lightning or switching events. This research proved that the deployment of flexible LPTs in the U.S power grid can greatly improve the grid reliability and its resiliency especially in the event of the loss of multiple LPTs. Moreover, the concept can significantly help reduce LPTs’ spare inventory by providing a high spare coverage level. The performed analysis showed that the designed 345 kV flexible LPT can serve as a spare for up to 34 units currently in operation in the U.S while the designed 230 kV flexible LPT can replace up to 101 units. Flexible LPTs offer new opportunities to U.S utilities to improve interchangeability of LPTs in the transmission system and to better strategize the upcoming renewal of about 70% of the population of LPTs anticipated to retire within the next two decades.

24 POWER TRANSMISSION AND DISTRIBUTION↗