Nedrow, Paul

Publications and source records attributed to Nedrow, Paul.

Inverse-collimated proton radiography for imaging thin materials

Relativistic, magnetically-focused proton radiography was invented at Los Alamos National Laboratory using the 800 MeV LANSCE beam, and is inherently well-suited to imaging dense objects, at areal densities >20 g cm -2 . However, if the unscattered portion of the transmitted beam is removed at the Fourier plane through inverse-collimation, this system becomes highly sensitive to very thin media, of areal densities <100 mg cm -2 . Here, this inversecollimation scheme is described in detail and demonstrated by imaging Xe gas with a shockwave generated by an aluminum plate compressing the gas at Mach 8.8. With a 5-mrad inverse collimator, an areal density change of just 49 mg cm-2 across the shock front is discernible with a contrast-to-noise ratio of 3. Geant4 modeling of idealized and realistic proton transports can guide the design of inverse-collimators optimized for specific experimental conditions and show that this technique performs better for thin targets with reduced incident proton beam emittance. This work increases the range of areal densities to which the system is sensitive to span from ~25 mg cm -2 to 100 g cm -2 , exceeding three orders of magnitude. This enables the simultaneous imaging of a dense system, as well as thin jets and ejecta material that are otherwise difficult to characterize with high-energy proton radiography.

47 OTHER INSTRUMENTATION↗

High-energy proton imaging for biomedical applications

The charged particle community is looking for techniques exploiting proton interactions instead of X-ray absorption for creating images of human tissue. Due to multiple Coulomb scattering inside the measured object it has shown to be highly non-trivial to achieve sufficient spatial resolution. We present imaging of biological tissue with a proton microscope. This device relies on magnetic optics, distinguishing it from most published proton imaging methods. For these methods reducing the data acquisition time to a clinically acceptable level has turned out to be challenging. In a proton microscope, data acquisition and processing are much simpler. This device even allows imaging in real time. The primary medical application will be image guidance in proton radiosurgery. Proton images demonstrating the potential for this application are presented. As a result, tomographic reconstructions are included to raise awareness of the possibility of high-resolution proton tomography using magneto-optics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ejecta model development at pRad (u)

In July 2009 we fielded three explosively (HE) driven Richtmyer-Meshkov instability experiments at the LANSCE Proton Radiography Facility (pRad), and in August of 2009 we fielded one flyer plate experiment on the pRad 40 mm powder gun. One HE experiment was done in vacuum, and the other two within four atmospheres of noble gasses: Xe and Ne. These two gases were chosen to study the viscous effects on ejecta formation. It is unexpected, but the viscosity {eta} of Ne is twice that of Xe, and, due to the atomic mass difference between the two, the kinematic viscosity ({eta}/{rho}) of Ne is about ten times that of Xe. The results showed that ejecta formation is sensitively linked to the gas density, which implies that the Weber number is more important in ejecta formation than the Reynolds number.

99 GENERAL AND MISCELLANEOUS↗

Ultra-high speed burst-mode imager for multi-frame radiography

A 720 x 720 pixel hybrid-CMOS imager was fabricated by Rockwell Scientific (now Teledyne Imaging Sensors). Several cameras have been in operation for 5 years, in a variety of static and dynamic experiments, at the 800MeV proton radiography (pRAD) facility at the LANSCE accelerator. The cameras can operate with a per-pulse adjustable inter-frame time of 250ns to 2s, and with an exposure/integration-time as short as 150 ns. Given the 800 ms total readout time, the imager can be externally synchronized to 0.1-to-5Hz, 50-ns wide proton beam pulses, and record 1000-frame radiographic movies of 5-to-30 minute duration. The effectiveness and dependence of the global electronic shutter on the pixelated Si photo-sensor bias voltage is discussed. The spatial resolution dependence of the full imaging system on various monolithic and structured scintillators is presented. We also present features of a new-generation 10-frame, 1024 x 1024 pixel, 50-ns exposure, 12-bit dynamic range imager, which is now in the design phase.

47 OTHER INSTRUMENTATION↗