Monophosphoryl Lipid A (MPLA) as an Innovative Immune Countermeasure to Mitigate Clinical Immunosuppression Risks for Exploration Space Missions
No abstract available
Engineering topics
Publications and source records attributed to Nelman-Gonzalez, Mayra.
No abstract available
NASA's Vision for Space Exploration centers on exploration class missions including the goals of returning to the moon and landing on Mars. One of NASA's objectives is to focus research on astronaut health and the development of countermeasures that will protect crewmembers during long duration voyages. Exposure to microgravity affects human physiology and results in changes in the urinary chemical composition favoring urinary supersaturation and an increased risk of stone formation. Nephrolithiasis is a multifactorial disease and development of a renal stone is significantly influenced by both dietary and environmental factors. Previous results from long duration Mir and short duration Shuttle missions have shown decreased urine volume, pH, and citrate levels and increased calcium. Citrate, an important inhibitor of calcium-containing stones, binds with urinary calcium reducing the amount of calcium available to form stones. Citrate inhibits renal stone recurrence by preventing crystal growth, aggregation, and nucleation and is one of the most common therapeutic agents used to prevent stone formation. Methods: Thirty long duration crewmembers (29 male, 1 female) participated in this study. 24-hour urines were collected and dietary monitoring was performed pre-, in-, and postflight. Crewmembers in the treatment group received two potassium citrate (KCIT) pills, 10 mEq/pill, ingested daily beginning 3 days before launch, all in-flight days and through 14 days postflight. Urinary biochemical and dietary analyses were completed. Results: KCIT treated subjects exhibited decreased urinary calcium excretion and maintained the levels of calcium oxalate supersaturation risk at their preflight levels. The increased urinary pH levels in these subjects reduced the risk of uric acid stones. Discussion: The current study investigated the use of potassium citrate as a countermeasure to minimize the risk of stone formation during ISS missions. Results suggest that supplementation with potassium citrate decreases the risk of stone formation during and immediately after spaceflight.
A spaceflight-compatible flow cytometer would be useful for the diagnosis of astronaut illness during long duration spaceflight and for conducting in-flight research to evaluate the effects of microgravity on human physiology. Until recently, the primary limitations preventing the development of a spaceflight compatible flow cytometer have been largely mechanical. Standard commercially available flow cytometers are large, complex instruments that use high-energy lasers and require significant training to operate. Standard flow cytometers function by suspending the particles to be analyzed inside a sheath fluid for analysis. This requires the presence of several liters of sheath fluid for operation, and generates a corresponding amount of liquid hazardous waste. The particles are then passed through a flow cell which uses the fluid mechanical property of hydrodynamic focusing to place the cells in single-file (laminar flow) as they pass through a laser beam for scanning and evaluation. Many spaceflight experiments have demonstrated that fluid physics is dramatically altered in microgravity (MSF [Manned Space Flight] Fluid Physics Data Sheet-August 1997) and previous studies have shown that sheath-fluid based hydrodynamic focusing may also be altered during microgravity (Crucian et al, 2000). For these reasons it is likely that any spaceflight compatible design for a flow cytometer would abandon the sheath fluid requirement. The elimination of sheath fluid would remove both the problems of weight associated with large volumes of liquids as well as the large volume of liquid waste generated. It would also create the need for a method to create laminar particle flow distinct from the standard sheath-fluid based method. The spaceflight prototype instrument is based on a recently developed commercial flow cytometer possessing a novel flow cell design that creates single-particle laser scanning and evaluation without the need for sheath-fluid based hydrodynamic focusing. This instrument also possesses a number of design advances that make it conditionally microgravity compatible: it is highly miniaturized and lightweight, uses a low energy diode laser, has a small number of moving parts, does not use sheath fluid and does not generate significant liquid waste. Although possessing certain limitations, the commercial cytometer functions operationally like a standard bench top laboratory flow cytometer, aspirating liquid particle samples and generating histogram or dot-plot data in standard FCS file format. In its current configuration however, the cytometer is limited to three parameter/two-color capability (two color PMTs + forward scatter), does not allow compensation between colors, does not allow linear analysis and is operated by rather inflexible software with limited capabilities. This is due to the fact that the cytometer has been designed and marketed as an instrument specific to a few particular assays, not as a multipurpose cytometer.