Griffith diffusers

Contoured wall diffusers are designed by using an inverse method. The prescribed wall velocity distribution(s) was taken from the high lift airfoil designed by A. A. Griffith in 1938; therefore, such diffusers are named Griffith diffusers. First the formulation of the inverse problem and the method of solution are outlined. Then the typical contour of a two-dimensional diffuser and velocity distributions across the flow channel at various stations are presented. For a Griffith diffuser to operate as it is designed, boundary layer suction is necessary. Discussion of the percentage of through-flow required to be removed for the purpose of boundary layer control is given. Finally, reference is made to the latest version of a computer program for a two-dimensional diffuser requiring only area ratio, nondimensional length and suction percentage as inputs.

Yang, T.-T.

An inverse problem design method for branched and unbranched axially symmetrical ducts

This paper concerns the potential flow design of axially symmetrical ducts of both circular and annular cross section with or without wall suction or blowing slots. The objective of the work was to develop a method by which such ducts could be designed with directly prescribed wall pressure variation. Previous axially symmetrical design methods applied only to circular cross sectional ducts and required that the pressure distribution be prescribed along the duct centerline and not along the duct wall. The present method uses an inverse problem approach which extends the method of Stanitz to the axially symmetrical case, and an approximation is used to account for the stagnation point in branched duct designs. Two examples of successful designs of diffusers with suction slots are presented.

Nelson, C. D.

Design and experimental performance of short curved wall diffusers with axial symmetry utilizing slot suction

The feasibility of designing short curved wall axially symmetrical subsonic diffusers utilizing suction through slots in the diffuser walls to prevent flow separation was investigated. A potential flow analysis was made, and a digital computer program was written for determining the diffuser wall contour for prescribed boundary conditions. The flow field included branch flow so that the suction slot geometry could be a part of the diffuser design. One bell shaped diffuser and three annular diffusers with area ratios of either 2.5:1 or 3:1 were designed, fabricated, and tested. Minimum suction requirements of metastable operation ranged from 6.3 percent to 12 percent when operating with inlet air velocities in the 1000 to 250 ft/sec (30 to 76 m/sec) range. For stable operation suction rates from 10 percent to 22 percent were required. In all cases the diffuser effectiveness was above 95 percent based on the conventional definition, and from 81 percent to 94 percent when the suction loss was accounted for. The exit velocity profiles were virtually flat with no more than + or - 9% variation over 95 percent of the exit area when operated with sufficient suction to prevent flow separation.

Yang, T.