Search NASA⌕ Search

Engineering topics

Nelson, Gilbert L.

Publications and source records attributed to Nelson, Gilbert L..

Practical Guide to Chemometric Analysis of Optical Spectroscopic Data

The methodology and mathematical treatment of several classic multivariate methods for the analysis of spectroscopic data is demonstrated in a straightforward way that can be used as a basis for teaching an undergraduate introductory course on chemometric analysis. The multivariate techniques of classical least squares (CLS), principal component regression (PCR), and partial least squares (PLS), as well as the univariate Beer’s law method have been described and compared, building students’ understanding by starting with the univariate method and progressing step by step into the multivariate methods. Equations for the production of regression vectors from training set spectral data is described and their use demonstrated for the prediction of constituent concentrations on a separate validation set of spectra. Extreme care is taken to ensure consistency in variable formatting of data matrices. This provides a key foundation to understanding how spectral data are manipulated using these different mathematical approaches for building quantitative regression models. Each method is applied to a real-world data set, and the results are discussed to show students the types of information that can be gleaned from each method. A training set comprised of 20 infrared absorbance spectra containing 3 constituents (benzene, polystyrene, and gasoline) of known composition are used to demonstrate the matrix operations for each regression method. A separate set of 12 real-world napalm samples (containing benzene, polystyrene and gasoline) are used as a validation set to demonstrate the ability to utilize the regression models on an unknown dataset. A toolbox (PNNL Chemometric Toolbox) written in MATLAB language is supplied in the Supplemental Information file and can be used as a companion for understanding the development and deployment of the chemometric algorithms described in this paper. The datasets of the infrared spectra are also supplied, allowing users to build and inspect the chemometric models on their own. Finally, the Toolbox includes scripts to assist users in loading their own datasets into MATLAB and performing CLS, PCR, and PLS on their data.

Upper-Division Undergraduate, Analytical Chemistry↗

Measuring Nd(III) Solution Concentration in the Presence of Interfering Er(III) and Cu(II) Ions: A Partial Least Squares Analysis of Ultraviolet–Visible Spectra

Optical spectroscopy is a powerful characterization tool with applications ranging from fundamental studies to real-time process monitoring. However, it can be difficult to apply to complex samples that contain interfering analytes which are common in processing streams. Multivariate (chemometric) analysis has been examined for providing selectivity and accuracy to the analysis of optical spectra and expanding its potential applications. Here we will discuss chemometric modeling with an in-depth comparison to more simplistic analysis approaches and outline how chemometric modeling works while exploring the limits on modeling accuracy. Understanding the limitations of the chemometric model can provide better analytical assessment regarding the accuracy and precision of the analytical result. This will be explored in the context of UV–Vis absorbance of neodymium (Nd 3+ ) in the presence of interferents, erbium (Er 3+ ) and copper (Cu 2+ ) under conditions simulating the liquid–liquid extraction approach used to recycle plutonium (Pu) and uranium (U) in used nuclear fuel worldwide. Finally, the selected chemometric model, partial least squares regression, accurately quantifies Nd 3+ with a low percentage error in the presence of interfering analytes and even under conditions that the training set does not describe.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enabling Microscale Processing: Combined Raman and Absorbance Spectroscopy for Microfluidic On-Line Monitoring

Microfluidics have many potential applications including characterization of chemical processes on a reduced scale, spanning the study of reaction kinetics using on-chip liquid–liquid extractions, sample pretreatment to simplify off-chip analysis, and for portable spectroscopic analyses. The use of in situ characterization of process streams from laboratory-scale and microscale experiments on the same chemical system can provide comprehensive understanding and in-depth analysis of any similarities or differences between process conditions at different scales. A well-characterized extraction of Nd(NO 3 ) 3 from an aqueous phase of varying NO 3– (aq) concentration with tributyl phosphate (TBP) in dodecane was the focus of this microscale study and was compared to an earlier laboratory-scale study utilizing counter current extraction equipment. Here, we verify that this same extraction process can be followed on the microscale using spectroscopic methods adapted for microfluidic measurement. Concentration of Nd (based on UV–vis) and nitrate (based on Raman) was chemometrically measured during the flow experiment, and resulting data were used to determine the distribution ratio for Nd. Extraction distributions measured on the microscale were compared favorably with those determined on the laboratory scale in the earlier study. Both micro-Raman and micro-UV–vis spectroscopy can be used to determine fundamental parameters with significantly reduced sample size as compared to traditional laboratory-scale approaches. This leads naturally to time, cost, and waste reductions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reimagining pH Measurement: Utilizing Raman Spectroscopy for Enhanced Accuracy in Phosphoric Acid Systems

Measurement of pH is an integral component of chemical studies and process control; however traditional pH probes are difficult to utilize in harsh or complex chemical systems. Optical spectroscopy-based on-line monitoring offers a powerful and novel route for characterizing system parameters, such as pH, and is well adapted to deployment in harsh environments or chemically complex systems. Specifically, Raman spectroscopy combined with chemometric analysis can provide an improved method of on-line pH measurement. Therefore, multivariate curve resolution analysis of Raman spectra can be utilized to determine speciation as a function of pH and subsequent chemometric modeling can be used to correlate spectral response to pH. This was demonstrated with phosphoric acid, a chemical system known to challenge traditional pH probes. Raman spectra exhibit clear changes with pH due to changing speciation, and chemometric modeling can be successfully utilized to correlate those fingerprints to pH. Using this approach, true pH of the phosphoric acid system can be measured with greater accuracy than with traditional pH probes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Online monitoring of solutions within microfluidic chips: simultaneous Raman and UV-Vis absorption spectroscopies

Microfluidics is an appealing analytical tool in the global effort to close the nuclear fuel cycle. Using a microfluidic chip permits analysis of greatly reduced sample volumes compared to what is necessary for traditional analytical methods. There is a commensurate reduction in disposal volume and cost. Development of spectroscopic methods practicable on the microscale are necessary to take advantage of the microchip configuration. This study uses simultaneously applied UV-vis and micro-Raman spectroscopies adapted to function on the microscale to analyze in situ both the Nd3+ (UV-vis active) and HNO3 (Raman active) concentrations in the same sample. An adjustable translation platform was designed to hold the micro-Raman probe above and perpendicular to the chip face, and the UV-vis probe in the plane of the chip. These complimentary spectral techniques when processed through multivariate PLS (Partial Least Squares) models gave an accurate picture of the widely varying solution concentrations as a function of time for each solution component. Solution matrix effects can drastically alter analyte signatures as measured by both UV-vis absorbance and Raman spectroscopy. PLS methods successfully modeled these spectral changes and accurately measured concentrations of components of interest within the microfluidic chip.

on-line monitoring, microfluidics, Raman, UV-vis↗

Micro-Raman technology to interrogate two-phase extraction on a microfluidic device

Microfluidic devices provide ideal environments to study solvent extraction. When droplets form and generate plug flow down the microfluidic channel, the device acts as a microreactor in which the kinetics of chemical reactions and interfacial transfer can be examined. Among the many benefits of microreactors is the ability to maintain small sample volumes, which is especially important when studying solvent extraction in harsh environments, such as in separations related to the nuclear fuel cycle. In solvent extraction, the efficiency of the process depends on complex formation and rates of transfer in biphasic systems. Thus, it is important to understand the kinetic parameters in an extraction system to maintain a high efficiency and effectivity of the process. Here we present a methodology that combines chemometric analysis with on-line micro-Raman spectroscopy to monitor biphasic extractions within a microfluidic device. This monitoring provided concentration measurements in both organic and aquoeus plugs as they flowed through the microfluidic channel. The biphasic system studied was comprised of HNO3 as the aqueous phase and 30 % (v/v) tributyl phosphate in n-dodecane comprised the organic phase, which simulated the Plutonium Uranium Redox EXtraction (PUREX) process. Using pre-equilibrated solutions (post extraction) the validity of the technique and methodology is illustrated. Following this validation, solutions that were not equilibrated were examined and the kinetics of interfacial mass transfer within the biphasic system were established. Results were compared to kinetics already determined on a macro scale to prove the efficacy of the technique

extraction, interfacial transport, liquid:liquid e↗

Development and testing of a novel micro-Raman probe and application of calibration transfer method for the quantitative analysis of microfluidic nitric acid streams

To simplify and improve the safety of reprocessing used nuclear fuel, an initial assessment was made of Raman microscopy applied to microfluidic volumes with a view toward the on-line spectroscopic measurement of highly radioactive solutions. This study compares a microscopic Raman probe (excitation focal point diameter 70 µm) to a larger, well studied probe (excitation focal point diameter 125 µm) used in prior investigations. This was done by chemometrically modeling and predicting concentrations of HNO3 solutions (0 M to 8 M) as they flowed through microfluidic cells based upon spectra from each probe. Spectra recorded for each probe using the same static HNO3 solution set contained in 2 dram glass vials were used as training sets to produce models for the respective probes. Modeling required baseline, normalization and smoothing preprocessing to compensate for a reduced path length between the static glass vial training set (4 cm) and the reduced path length flow cell (1 cm), wide ranging solution concentrations, and the associated non-linear spectral changes, and abrupt and uneven concentration changes of flowing solutions. The micro-Raman probe is able to produce spectra that may be analyzed chemometrically to accurately predict the concentration of flowing HNO3 solutions down to microliter volumes. Based upon RMSECV and RMSEP modeling statistics concentration predictions of the micro-Raman probe are comparable to those obtained for a macro-Raman on identical samples.

microscopic Raman probe, MicroRaman, nitric acid, ↗

Multivariate Analysis To Quantify Species in the Presence of Direct Interferents: Micro-Raman Analysis of HNO 3 in Microfluidic Devices

Microfluidic devices are a growing field with significant potential for application to small scale processing of solutions. Much like large scale processing, fast, reliable, and cost effective means of monitoring the streams during processing are needed. Here we apply a novel Micro-Raman probe to the on-line monitoring of streams within a microfluidic device. For either macro or micro scale process monitoring via spectroscopic response, there is the danger of interfering or confounded bands obfuscating results. By utilizing chemometric analysis, a form of multivariate analysis, species can be accurately quantified in solution despite the presence of overlapping or confounded spectroscopic bands. This is demonstrated on solutions of HNO 3 and NaNO 3 within micro-flow and microfluidic devices.

Lines, Amanda M.↗

Advances in Online Monitoring for Measurement within Nuclear Fuel Reprocessing Streams

Abstract – Significant effort has been focused on the back end of the nuclear fuel cycle including treatment and reuse of irradiated fuel. Solvent extraction reprocessing methods that have been developed often contain various steps, with each one tailored to the separation of specific radionuclides, which are highly dependent upon solution properties. The instrumentation used to monitor these processes must be robust, require little or no maintenance, and be able to withstand harsh environments such as high radiation fields and aggressive chemical matrices. Our group has been investigating the use of optical spectroscopy for the on-line monitoring of actinides, lanthanides, and acid strength within fuel reprocessing streams. This paper describes the application of the electronic and vibrational spectroscopic techniques for radiochemical process monitoring. In this context, our team experimentally assessed the potential of Raman and UV-vis spectroscopic techniques for online real-time monitoring of the U(VI)/nitrate ion/nitric acid and Pu(VI/IV)/Np(VI/V/IV)/Nd(III) in solutions relevant to used nuclear fuel reprocessing. These techniques demonstrated robust performance in the repetitive batch measurements of each analyte in a wide concentration range using simulant and commercial dissolved used fuel solutions. Currently this has been demonstrated on the macroscopic scale, using sample probes requiring large solution volumes. In an effort to minimize waste and reduce dose to personnel, we have modified this technique to allow measurement at the microfluidic scale using a Raman microprobe. Under the current sampling environment, Raman samples typically require upwards of 10 mL and larger. Using the new sampling system, we can sample volumes at 10 µL or less, which is a scale reduction of over 1,000 fold in sample size. This will significantly reduce the requirements for handling hazardous materials, and greatly reduce the costs associated with worker protection from exposure to radioactive and hazardous materials, and costs due to waste disposal.

process monitoring, U, nitric acid, microfluidic, ↗