A Comparison of the Performance of Three Nongradient-Based Optimization Algorithms During the Design of an Accelerator-Driven Subcritical Assembly for Mo-99 Production
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Nelson, Noel.
Explore the source record for details and available documents.
Molybdenum-99 (99Mo) has been in short supply in the recent decades. The most common productionmechanism, irradiation in a reactor fueled by highly enriched uranium (HEU), raisesproliferation concerns. Novel efforts are being pursued to meet the demand for 99Mo withoutHEU irradiation, relying on the processing of low-enriched uranium or natural uranium. Onesuch concept is to use an electron linear accelerator to generate bremsstrahlung that, through aphotonuclear reaction, can help multiply neutrons in a subcritical assembly. The goal of this workwas to neutronically optimize the subcritical assembly for keff and 99Mo production. This optimizationis unique for The design was optimized in terms of reflector type, pitch, and LEU andNU mass. Results of the paper show the effects of fuel mass, pitch, and reflector material on keffand the NU fission fraction. keff was found to be mostly driven by LEU mass, and the NU fissionfraction was dependent on several parameters, primarily pitch and mass.
Method for visualizing and interacting with ionizing radiation data using augmented reality. This code provides coupling radiation transport data with immersive augmented reality experiences for users in real-world environments. Moreover, it provides real-time, simulation-based, radiation exposure feedback to user as a function of behavior in the immersive environment.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
On January 23–25, 2018 in Washington, DC, the National Nuclear Security Administration (NNSA) Office of Defense Nuclear Nonproliferation (DNN) Research and Development (NA-22) supported the three-day Nuclear Data Roadmapping and Enhancement Workshop (NDREW) to enable nonproliferation missions. The goal was to assemble users and producers of nuclear data to provide input to identify nuclear data needs, suggest solutions to address these needs, and rank potential solutions with regard to mission impact. The workshop was organized into 12 discussion sessions which were bookended by introductory and concluding presentations. Eight discussion topics were defined by specific nuclear reaction or data types, while the other four covered infrastructure, benchmarks, uncertainties, and code development needs. Over 110 attendees represented national laboratories, universities, and headquarters, as well as international collaborators and industry representatives. Based on survey results and other feedback, attendees found the workshop valuable since it initiated a new conversation between programs and provided collaborative opportunities across stakeholder groups such as data users and experimentalists/evaluators. The proceedings presented herein summarize the content of the workshop, provide session notes and important highlights, and documents recommendations from the attendees.
The data integration with modeled predictions (DIMP) model is a promising inverse radiation transport method for solving the special nuclear material (SNM) holdup problem. Unlike previous methods, DIMP is a completely passive nondestructive assay technique that requires no initial assumptions regarding the source distribution or active measurement time. DIMP predicts the most probable source location and distribution through Bayesian inference and quasi-Newtonian optimization of predicted detector re-sponses (using the adjoint transport solution) with measured responses. DIMP performs well with for-ward hemispherical collimation and unshielded measurements, but several considerations are required when using narrow-view collimated detectors. DIMP converged well to the correct source distribution as the number of synthetic responses increased. DIMP also performed well for the first experimental validation exercise after applying a collimation factor, and sufficiently reducing the source search vol-ume's extent to prevent the optimizer from getting stuck in local minima. DIMP's simple point detector response function (DRF) is being improved to address coplanar false positive/negative responses, and an angular DRF is being considered for integration with the next version of DIMP to account for highly collimated responses. Overall, DIMP shows promise for solving the SNM holdup inverse problem, especially once an improved optimization algorithm is implemented.
Detector response functions (DRFs) are often used for inverse analysis. We compute the DRF of a sodium iodide (NaI) nuclear material holdup field detector using the code named g03 developed by the Center for Engineering Applications of Radioisotopes (CEAR) at NC State University. Three measurement campaigns were performed in order to validate the DRF’s constructed by g03: on-axis detection of calibration sources, off-axis measurements of a highly enriched uranium (HEU) disk, and on-axis measurements of the HEU disk with steel plates inserted between the source and the detector to provide attenuation. Furthermore, this work quantifies the uncertainty of the Monte Carlo simulations used in and with g03, as well as the uncertainties associated with each semi-empirical model employed in the full DRF representation. Overall, for the calibration source measurements, the response computed by the DRF for the prediction of the full-energy peak region of responses was good, i.e. within two standard deviations of the experimental response. In contrast, the DRF tended to overestimate the Compton continuum by about 45–65% due to inadequate tuning of the electron range multiplier fit variable that empirically represents physics associated with electron transport that is not modeled explicitly in g03. For the HEU disk measurements, computed DRF responses tended to significantly underestimate (more than 20%) the secondary full-energy peaks (any peak of lower energy than the highest-energy peak computed) due to scattering in the detector collimator and aluminum can, which is not included in the g03 model. We ran a sufficiently large number of histories to ensure for all of the Monte Carlo simulations that the statistical uncertainties were lower than their experimental counterpart’s Poisson uncertainties. The uncertainties associated with least-squares fits to the experimental data tended to have parameter relative standard deviations lower than the peak channel relative standard deviation in most cases and good reduced chi-square values. The highest sources of uncertainty were identified as the energy calibration polynomial factor (due to limited source availability and NaI resolution) and the Ba-133 peak fit (only a very weak source was available), which were 20% and 10%, respectively.
Detector response functions (DRFs) have become the subject of increasing scientific interest for the last thirty years in several industrial applications of radiation detection. These applications include gamma-ray, prompt gamma-ray, and X-ray spectrometry for elemental analysis and location as applied to mining, radio-tracing in medicine, and holdup source characterization. However, it is difficult to create a rigorous mathematical formulation of the DRF. Therefore, semi-empirical and stochastic approaches have been developed instead to construct detector and application specific DRFs. A DRF can be considered to be a function that converts the energy-dependent incidence of incoming source particles onto a detector into a detector response spectrum that simulates the experimental response. The DRF can also be used in the reverse sense in an inverse problem setting, as a step in the process of predicting the physical characteristics of an unknown source (e.g. the holdup problem and library spectra). Much of the recent work on DRFs has been performed by Gardner. He has developed accurate DRF models through semi-empirical curve fitting and Monte Carlo simulation. His DRFs for 3" X 3" NaI detectors have been developed with the experimental measurements taken by Heath and for 6"x6" bare (unshielded) NaI(Tl) detector data with single-energy sources centered on the detector face at a distance of 10 cm. There was agreement with the Heath benchmark detector measurements within two Poisson standard deviations of the measured data. DRFs have also been developed for other detectors such as high purity Germanium detectors and Si(Li) for the same geometries as NaI. Other than a few artifacts such as backscatter peaks, there was good agreement between simulated responses and the experimental data.