Search NASA⌕ Search

Engineering topics

Nelson, S L

Publications and source records attributed to Nelson, S L.

At least 19 records

Radiochemistry as a (rho)R Diagnostic with the RAGS Gas Collection System

Radiochemical diagnostic techniques such as gas-phase capsule debris analysis may prove to be successful methods for establishing the success or failure of ignition experiments at the National Ignition Facility (NIF). Samples in the gas phase offer the most direct method of collection by simply pumping out the large target chamber following a NIF shot. The target capsules will be prepared with dopants which will produce radioactive noble gas isotopes upon activation with neutrons. We have designed and constructed the Radchem Apparatus for Gas Sampling (RAGS) in order to collect post-shot gaseous samples for NIF capsule diagnostics. The design of RAGS incorporates multiple stages intended to purify, transfer, and count the radioactive decays from gaseous products synthesized in NIF experiments. At the moment the dopant of choice is {sup 124}Xe, which will undergo (n,{gamma}) and (n, 2n) reactions to produce {sup 125}Xe and {sup 123}Xe. The half-lives of each are on the order of multiple hours and are suitable for long-term gamma-counting. These isotopes and the rest of the gases evolved in a NIF shot will be drawn through the NIF turbo pumps, past the temporarily shuttered cryo pumps (to aid our collection efficiency), and towards the first main portion of the RAGS system: the pre-cleaner. The pre-cleaner will consist of a water removal system, a series of heated getter cartridges to remove most other impurities such as N{sub 2}, O{sub 2}, CO{sub 2}, etc., and a residual gas analyzer (RGA) to monitor vacuum quality. The noble gases will flow through the precleaner and into the second stage of the system: the cryo collector. This cryo collector consists of a main cryo head for noble gas collection which will operate for approximately five minutes post-shot. Afterwards a valve will close and isolate the pre-cleaner, while the cryo head warms to release the Xe gas to one of two locations - either a second cryo station for in-situ gamma counting, or to a small cooled gas bottle for removal and counting. Additional capabilities of the RAGS system include a noble gas calibration apparatus attached to the NIF target chamber, which will be operated hours pre-shot to determine collection efficiency through the whole RAGS system via the signal detected from the RGA. Also it is possible there will be the addition of a helium puff system to drive the Xe through the pre-cleaner and collection stations. It is also likely that multiple cryo collection stations will be built into the system in the future to fractionate and collect other noble gases such as Kr, Ar, and possibly Ne. A prototype pre-cleaner has been built at Lawrence Berkeley National Laboratory (LBNL) and is in the testing phases. The information learned in this testing will help collaborators at Sandia National Laboratory that are building and delivering the systems that will be deployed at NIF. The LBNL testing so far has demonstrated that radioactive fission gases can be flowed through the system with and without carrier gases of air and/or He, and the activity can be collected on an activated charcoal sample. Further testing in the upcoming months will hopefully yield more information about any presence of Xe in the water removed from the system, and commissioning of a small cryo cooler as well.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Aerosol-Assisted Solid Debris Collection for the National Ignition Facility

The National Ignition Facility (NIF) has been completed and has made its first shots on-target. While upcoming experiments will be focused on achieving ignition, a variety of subsequent experiments are planned for the facility, including measurement of cross sections, astrophysical measurements, and investigation of hydrodynamic instability in the target capsule. In order to successfully execute several of these planned experiments, the ability to collect solid debris following a NIF capsule shot will be required. The ability to collect and analyze solid debris generated in a shot at the National Ignition Facility (NIF) will greatly expand the number of nuclear reactions studied for diagnostic purposes. Currently, reactions are limited to only those producing noble gases for cryogenic collection and counting with the Radchem Apparatus for Gas Sampling (RAGS). The radchem solid collection diagnostic has already been identified by NIF to be valuable for the determination and understanding of mix generated in the target capsule's ablation. LLNL is currently developing this solid debris collection capability at NIF, and is in the stage of testing credible designs. Some of these designs explore the use of x-ray generated aerosols to assist in collection of solid debris. However, the variety of harsh experimental conditions this solid collection device will encounter in NIF are challenging to replicate. Experiments performed by Gary Grim et al. at Sandia National Laboratory's RHEPP1 facility have shown that ablation causes a cloud of material removed from an exposed surface to move normal to and away from the surface. This ablation is certain to be a concern in the NIF target chamber from the prompt x-rays, gamma rays, etc. generated in the shot. The cloud of ablated material could interfere with the collection of the desired reaction debris by slowing down the debris so that the kinetic energy is too low to allow implantation, or by stopping the debris from reaching the collection device entirely. Our goal is to use this primary ablation wave to our advantage, by the creation of ionized alkali metal halide salt aerosols. This technique is similar to that used by many particle accelerator groups for gas-jet transport. Ideally the salt would be ablated from a substrate, encounter the reaction debris, agglomerate, and be collected for further study. We have done studies at laser and pulsed-power facilities (Titan laser at LLNL, Trident laser at LANL, Zebra z-pinch at Nevada Terawatt Facility) evaluating the hardiness of materials for placement in the NIF target chamber, as well as testing aerosol generation by the incident x-rays generated in device shots. To test this method's potential success in the NIF environment, we have tested KCl, KI, RbI, and CsI films of 1 and 2 um linear thickness on aluminum and silicon wafer substrates in these aforementioned facilities, at varied distances. These salts do ablate in the presence of sufficient x-ray fluence. Further analysis to quantify the final ablation depth as a function of x-ray fluence is ongoing. Half of each sample was masked with a thick tungsten foil for photon opacity. KCl was the most difficult salt to ablate, from comparing the tungsten-masked side of the samples to the unmasked side of the samples. This is likely due to KCl's absorbance peak being at lower wavelengths than that of KI, {approx}160 nm vs. {approx}220 nm, respectively. Samples with and without collimation were tested to identify if any condensation of these ablated salts occurred after ablation. Visual inspection of the silicon wafer witness plates placed parallel to the direction of the incident photons showed that a vapor was deposited on the wafers next to the collimators. Further analysis with EDS in the case of the collimated samples conclusively identified the vapor as CsI. We also intend to examine samples of bare substrate exposed to the same experimental conditions for post-shot change via SEM images, optical microscopy, and atomic force microscopy (AFM). Furthermore, tests with separated isotopes may be done to reduce background contamination. When sample optimization is complete, we plan to develop a 'catcher' device for these desorbed aerosols. Current ideas include biased grids to either attract the ionized particles to the grid, or repel them towards a collection device.

36 MATERIALS SCIENCE↗

Measurement of the 208Pb(52Cr, n)259Sg Excitation Function

The excitation function for the 208Pb(52Cr, n)259Sg reaction has been measured using the Berkeley Gas-filled Separator at the Lawrence Berkeley National Laboratory 88-Inch Cyclotron. The maximum cross section of pb is observed at a center-of-target laboratory-frame energy of 253.0 MeV. In total, 25 decay chains originating from 259Sg were observed and the measured decay properties are in good agreement with previous reports. In addition, a partial excitation function for the 208Pb(52Cr, 2n)258Sg reaction was obtained, and an improved 258Sg half-life of ms was calculated by combining all available experimental data.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

New Isotope 263Hs

A new isotope of Hs was produced in the reaction 208Pb(56Fe, n)263Hs at the 88-Inch Cyclotron of the Lawrence Berkeley National Laboratory. Six genetically correlated nuclear decay chains have been observed and assigned to the new isotope 263Hs. The measured cross section was 21+13-8.4 pb at 276.4 MeV lab-frame center-of-target beam energy. 263Hs decays with a half-life of 0.74 ms by alpha-decay and the measured alpha-particle energies are 10.57 +- 0.06, 10.72 +- 0.06, and 10.89 +- 0.06 MeV. The experimental cross section is compared to a theoretical prediction based on the Fusion by Diffusion model [W. J. Swiatecki et al., Phys. Rev. C 71, 014602 (2005)].

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiochemistry diagnostics for the National Ignition Facility

Radiochemistry-based techniques will be an important complement to x-ray implosion diagnostics. Simulations demonstrate the value of alpha-induced or deuteron-induced reactions as a direct measurement of static mix contamination in DT-filled ignition capsules. In this proceedings we examine to what extent neutron-induced reactions might be highly correlated with the energetically down-scattered neutron fraction which is, in turn, related to the critical quantity of fuel areal density, {rho}R. Although alpha and deuteron reactions are highly suppressed in HT/D-filled capsules, neutron-induced reactions produce robust abundances and 2% measurements of the relevant radiological ratios is achievable. We conclude that radiochemical data are strongly correlated with the down-scattered fraction and fuel areal density. Unknown physics, primarily uncertainties in the direct T-T fusion neutron cross section and, to a lesser extent, various radiochemical production cross sections are important but calibration shots can be used to reduce these errors. The primary advantage of radiochemistry remains - it is the only technique that samples down-scattered neutrons from the entire capsule during the burn. In particular radiochemistry correlated with other diagnostics can be used to minimize experimental uncertainties and thus maximize gain.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

High-K multi-quasiparticle states and rotational bands in {sub 103}{sup 255}Lr

Two isomeric states have been identified in {sup 255}Lr. The decay of the isomers populates rotational structures. Comparison with macroscopic-microscopic calculations suggests that the lowest observed sequence is built upon the [624]9/2{sup +} Nilsson state. However, microscopic cranked relativistic Hartree-Bogoliubov (CRHB) calculations do not reproduce the moment of inertia within typical accuracy. This is a clear challenge to theories describing the heaviest elements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear physics and heavy element research at LLNL

This paper highlights some of the current basic nuclear physics research at Lawrence Livermore National Laboratory (LLNL). The work at LLNL concentrates on investigating nuclei at the extremes. The Experimental Nuclear Physics Group performs research to improve our understanding of nuclei, nuclear reactions, nuclear decay processes and nuclear astrophysics; an expertise utilized for important laboratory national security programs and for world-class peer-reviewed basic research.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Multi-quasiparticle states in {sup 256}Rf

Excited states in {sup 256}Rf were populated via the {sup 208}Pb({sup 50}Ti,2n) fusion-evaporation reaction. Delayed {gamma}-ray and electron decay spectroscopy was performed and three isomeric states in {sup 256}Rf have been identified. A fourth low-energy nonyrast state was identified from the {gamma}-ray decay of one of the higher lying isomers. The states are interpreted as multi-quasiparticle excitations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the {sup 208}Pb({sup 52}Cr,n){sup 259}Sg excitation function

The excitation function for the {sup 208}Pb({sup 52}Cr,n){sup 259}Sg reaction has been measured using the Berkeley Gas-filled Separator at the Lawrence Berkeley National Laboratory 88-Inch Cyclotron. The maximum cross section of 320{sub -100}{sup +110} pb is observed at a center-of-target laboratory-frame energy of 253.0 MeV. In total, 25 decay chains originating from {sup 259}Sg were observed and the measured decay properties are in good agreement with previous reports. In addition, a partial excitation function for the {sup 208}Pb({sup 52}Cr,2n){sup 258}Sg reaction was obtained, and an improved {sup 258}Sg half-life of 2.6{sub -0.4}{sup +0.6} ms was calculated by combining all available experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of complementary reactions in the production of Mt

The new reaction {sup 208}Pb({sup 59}Co,n){sup 266}Mt was studied using the Berkeley Gas-filled Separator at the Lawrence Berkeley National Laboratory 88-Inch Cyclotron. A cross section of 7.7{sub -3.3}{sup +5.2} pb was measured at a compound nucleus excitation energy of 14.9 MeV. The measured decay properties of {sup 266}Mt and its daughters correspond well with existing data. We compare this experimental result to transactinide compound nucleus formation model predictions, and the previously studied {sup 209}Bi({sup 58}Fe,n){sup 266}Mt reaction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New isotope {sup 263}Hs

A new isotope of Hs was produced in the reaction {sup 208}Pb({sup 56}Fe,n){sup 263}Hs at the 88-Inch Cyclotron of the Lawrence Berkeley National Laboratory. Six genetically correlated nuclear decay chains have been observed and assigned to the new isotope {sup 263}Hs. The measured cross section was 21{sub -8.4}{sup +13} pb at 276.4 MeV lab frame center-of-target beam energy. {sup 263}Hs decays with a half-life of 0.74{sub -0.21}{sup +0.48} ms by {alpha}-decay and the measured {alpha}-particle energies are 10.57 {+-} 0.06, 10.72 {+-} 0.06, and 10.89 {+-} 0.06 MeV. The experimental cross section is compared to a theoretical prediction based on the Fusion by Diffusion model [W. J. SwiaPtecki et al., Phys. Rev. C 71, 014602 (2005)].

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Extraction of niobium and tantalum isotopes using organophosphorus compounds -- Part II -- Extraction of 'carrier-free' concentrations from HCl/LiCl solutions

We have studied the extraction of niobium and tantalum from mixed hydrochloric acid/lithium chloride media by bis(2-ethylhexyl) hydrogen phosphate (HDEHP) and bis(2-ethylhexyl) hydrogen phosphite (BEHP) as a function of hydrogen ion (H+) concentration. The amount of niobium extracted by both HDEHP and BEHP decreased with increasing hydrogen ion concentration. Equilibrium with niobium occurred within 10 s at all hydrogen ion concentrations for both systems. For tantalum, the amount extracted increased until 6 - 9 M H+, before decreasing at higher H+ concentrations when extracted by both HDEHP and BEHP. Equilibrium occurred within 10 s at two H+ concentrations when extracted by HDEHP. The data obtained are used as the basis to discuss the speciation of Nb and Ta under the conditions studied and to evaluate possible extraction mechanisms.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Comparison of reactions for the production of {sup 258,257}Db: {sup 208}Pb({sup 51}V,xn) and {sup 209}Bi({sup 50}Ti,xn)

Excitation functions for the 1n and 2n exit channels of the {sup 208}Pb({sup 51}V,xn){sup 259-x}Db reaction were measured. A maximum cross section of the 1n exit channel of 2070{sub -760}{sup +1100} pb was measured at an excitation energy of 16.0 {+-} 1.8 MeV. For the 2n exit channel, a maximum cross section of 1660{sub -370}{sup +450} pb was measured at 22.0 {+-} 1.8 MeV excitation energy. The 1n excitation function for the {sup 209}Bi({sup 50}Ti,n){sup 258}Db reaction was remeasured, resulting in a cross section of 5480{sub -1370}{sup +1730} pb at an excitation energy of 16.0 {+-} 1.6 MeV, in agreement with previous values [F. P. Hessberger et al., Eur. Phys. J. A 12, 57 (2001)]. Differences in cross section maxima are discussed in terms of the fusion probability below the barrier.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Influence of projectile neutron number in the {sup 208}Pb({sup 48}Ti, n){sup 255}Rf and {sup 208}Pb({sup 50}Ti, n){sup 257}Rf reactions

Four isotopes of rutherfordium, {sup 254-257}Rf, were produced by the {sup 208}Pb({sup 48}Ti, xn){sup 256-x}Rf and {sup 208}Pb({sup 50}Ti, xn){sup 258-x}Rf reactions (x=1,2) at the Lawrence Berkeley National Laboratory 88-Inch Cyclotron. Excitation functions were measured for the 1n and 2n exit channels. A maximum likelihood technique, which correctly accounts for the changing cross section at all energies subtended by the targets, was used to fit the 1n data to allow a more direct comparison between excitation functions obtained under different experimental conditions. The maximum 1n cross sections of the {sup 208}Pb({sup 48}Ti, n){sup 255}Rf and {sup 208}Pb({sup 50}Ti, n){sup 257}Rf reactions obtained from fits to the experimental data are 0.38{+-}0.07 nb and 40{+-}5 nb, respectively. Excitation functions for the 2n exit channel were also measured, with maximum cross sections of 0.40{sub -0.17}{sup +0.27} nb for the {sup 48}Ti induced reaction, and 15.7{+-}0.2 nb for the {sup 50}Ti induced reaction. The impact of the two neutron difference in the projectile on the 1n cross section is discussed. The results are compared to the Fusion by Diffusion model developed by Swiatecki, Wilczynska, and Wilczynski.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of complementary reactions for the production of {sup 261,262}Bh

Two heavy-ion induced fusion reactions producing {sup 261,262}Bh were studied using the Berkeley Gas-filled Separator at the Lawrence Berkeley National Laboratory 88-Inch Cyclotron. An excitation function for the production of {sup 262}Bh via the reaction {sup 209}Bi({sup 54}Cr,n){sup 262}Bh was measured with a maximum cross section from a fit to the data of 430 {+-} 110 pb observed at a compound nucleus excitation energy of 15.7 MeV. New data have been measured for the 1n exit channel of the {sup 208}Pb({sup 55}Mn, n){sup 262}Bh reaction. We present an updated excitation function with an observed maximum cross section of 530{+-}100 pb at a compound nucleus excitation energy of 14.1 MeV. Events corresponding to the 2n exit channel for the {sup 209}Bi({sup 54}Cr,2n){sup 261}Bh and {sup 208}Pb({sup 55}Mn,2n){sup 261}Bh reactions were also observed and are presented as partial excitation functions. The measured decay properties correspond well with existing experimental data. We compare these experimental results to cross section predictions from a model by Swiatecki et al. and discuss entrance channel effects on the magnitude of 1n cross sections.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗