Mitigation of Aerosol Impacts of Ash Deposition and Emissions from Coal Combustion (Final Technical Report)
This project was selected under FOA-0001989 Area of Interest (AOI) 2 – Power Plant Component Improvement. The objective of this AOI was to test and validate technologies and methodologies that can improve the efficiency, reliability, and/or flexibility of individual power plant components in existing plants. The aerosol mitigation technology comprises injection of sorbent into the boiler through injection lances using a positive-pressure blower. The injected sorbent interacts with flame-vaporized aerosolforming components produced during combustion reducing the abundance of sub-micrometer (< 1 micron) particles and fireside ash deposits in the boiler. The primary objective of this project was to validate a sorbent-based technology for mitigating fireside heat transfer surface fouling-related challenges in a full-scale coal-fired power generation facility, thereby, improving plant performance and reliability.