Search NASA⌕ Search

Engineering topics

Nemer, Martin B.

Publications and source records attributed to Nemer, Martin B..

Bayesian Inference applied to the Solubility of Phase-3 and Phase-5

This Section covers an introduction to the objectives and techniques used in this analysis. The objectives of the report are given in Subsection 1.1. An introduction to aqueous thermodynamics and how variance might propagate through the relevant thermodynamic equations is given in Subsection 1.2. An introduction to Bayesian inference and its application to thermodynamic modeling is given in Subsection 1.3.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Crystal structures of polymerized lithium chloride and dimethyl sulfoxide in the form of {2LiCl·3DMSO} n and {LiCl·DMSO} n

Two novel LiCl·DMSO polymer structures were created by combining dry LiCl salt with dimethyl sulfoxide (DMSO), namely, catena-poly[[chlorido­lithium(I)]-μ-(dimethyl sulfoxide)-κ 2 O:O-[chlorido­lithium(I)]-di-μ-(dimethyl sulfoxide)-κ 4 O:O], [Li 2 Cl 2 (C 2 H 6 OS) 3 ]n, and catena-poly[lithium(I)-μ-chlorido-μ-(dimethyl sulfoxide)-κ 2 O:O], [LiCl(C 2 H 6 OS)]n. The initial synthesized phase had very small block-shaped crystals (<0.08 mm) with monoclinic symmetry and a 2 LiCl: 3 DMSO ratio. As the solution evaporated, a second phase formed with a plate-shaped crystal morphology. After about 20 minutes, large (>0.20 mm) octa­hedron-shaped crystals formed. The plate crystals and the octa­hedron crystals are the same tetra­gonal structure with a 1 LiCl: 1 DMSO ratio. These structures are reported and compared to other known LiCl·solvent compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gamma radiation sterilization of N95 respirators leads to decreased respirator performance

In response to personal protective equipment (PPE) shortages in the United States due to the Coronavirus Disease 2019, two models of N95 respirators were evaluated for reuse after gamma radiation sterilization. Gamma sterilization is attractive for PPE reuse because it can sterilize large quantities of material through hermetically sealed packaging, providing safety and logistic benefits. The Gamma Irradiation Facility at Sandia National Laboratories was used to irradiate N95 filtering facepiece respirators to a sterilization dose of 25 kGy(tissue). Aerosol particle filtration performance testing and electrostatic field measurements were used to determine the efficacy of the respirators after irradiation. Both respirator models exhibited statistically significant decreases in particle filtering efficiencies and electrostatic potential after irradiation. The largest decrease in capture efficiency was 40–50% and peaked near the 200 nm particle size. The key contribution of this effort is correlating the electrostatic potential change of individual filtration layer of the respirator with the decrease filtration efficiency after irradiation. This observation occurred in both variations of N95 respirator that we tested. Electrostatic potential measurement of the filtration layer is a key indicator for predicting filtration efficiency loss.

36 MATERIALS SCIENCE↗

Remote vibration sensing through opaque media using permanent magnets

A method of sensing vibrations or displacements remotely is provided. Magnets are attached to vibrating objects or the vibrating objects themselves are magnetic. A number of magnetic sensors are placed a specified distance from the magnets. Vibrational displacement of the vibrating objects is determined according to a model that maps changes in magnetic field to vibrations or spatial displacements.

Mazumdar, Yi Chen↗

COVID-19 global pandemic planning: Performance and electret charge of N95 respirators after recommended decontamination methods

Shortages of N95 respirators for use by medical personnel have driven consideration of novel conservation strategies, including decontamination for reuse and extended use. Decontamination methods listed as promising by the Centers for Disease Control and Prevention (CDC) (vaporous hydrogen peroxide (VHP), wet heat, ultraviolet irradiation (UVI)) and several methods considered for low resource environments (bleach, isopropyl alcohol and detergent/soap) were studied for two commonly used surgical N95 respirators (3M™ 1860 and 1870+ Aura™). Although N95 filtration performance depends on the electrostatically charged electret filtration layer, the impact of decontamination on this layer is largely unexplored. As such, respirator performance following decontamination was assessed based on the fit, filtration efficiency, and pressure drop, along with the relationship between (1) surface charge of the electret layer, and (2) elastic properties of the straps. Decontamination with VHP, wet heat, UVI, and bleach did not degrade fit and filtration performance or electret charge. Isopropyl alcohol and soap significantly degraded fit, filtration performance, and electret charge. Pressure drop across the respirators was unchanged. Modest degradation of N95 strap elasticity was observed in mechanical fatigue testing, a model for repeated donnings and doffings. CDC recommended decontamination methods including VHP, wet heat, and UV light did not degrade N95 respirator fit or filtration performance in these tests. Extended use of N95 respirators may degrade strap elasticity, but a loss of face seal integrity should be apparent during user seal checks. NIOSH recommends performing user seal checks after every donning to detect loss of appropriate fit. Decontamination methods which degrade electret charge such as alcohols or detergents should not be used on N95 respirators. The loss of N95 performance due to electret degradation would not be apparent to a respirator user or evident during a negative pressure user seal check.

60 APPLIED LIFE SCIENCES↗

Alternative Materials for Mask Construction by the Public

N95 respirators became scarce to the general public in mid-to-late March of 2020 due to the SARS-CoV-2 epidemic. By mid-April of 2020, most states in the United States were requiring face coverings to be worn while in public enclosed places and in busy outdoor areas where groups of people were in close proximity. Many resorted to cloth masks, homemade masks, procedure masks obtained through online purchases, and other ad-hoc means. Thus, there was and still is a need to determine the aerosol filtration efficacy of commonly available materials that can be used for homemade mask construction. This study focused on non- woven polymeric fabrics that are readily available for homemade mask construction. The conclusion of this study is that non-woven materials that carry a high electric charge or those that can easily acquire charge had the highest aerosol filtration efficiency per unit of pressure drop. Future work should examine a wider variety of these materials and determine the maximum pressure drop that a nominal homemade mask can withstand before a significant portion of airflow is diverted around the mask. More broadly, a better understanding of the charge state on non-woven materials and impact of that charge state on filtration efficiency is needed.

36 MATERIALS SCIENCE↗

Sterilization of N95 Respirators via Gamma Radiation: Comparison of Post-sterilization Efficacy

This study evaluated gamma irradiation for sterilization and reuse of two models of N95 respirators after gamma radiation sterilization as a method to increase availability of N95 respirators during a shortage. The Sandia National Laboratories Gamma Irradiation Facility was used to irradiate two different models of N95 filtering facepiece respirators at doses ranging from 0 kGy(tissue) to 50 kGy(tissue). The following tests were used to determine the efficacy of the respirator after irradiation sterilization: Ambient Aerosol Condensation Nuclei Counter Quantitative Fit Test, tensile test, strain cycling, oscillatory dynamic mechanical analysis, microscopic image analysis of fiber layers, and electrostatic field measurements. Both of the respirator models exhibited statistically significant changes after gamma irradiation as shown by the Quantitative Fit Test, electrostatic testing and the aerosol testing. The change in electrostatic capability of the filter reduced the efficiency of challenging particles near the 200 nm size by approximately 40-50%. Both tested respirators showed statistically significant changes associated with gamma sterilization. However, our results indicate that choices in materials and manufacturing methods to achieve N95 filtration lead to different magnitudes of damage when exposed to gamma radiation at sterilization relevant doses. This damage results in lower filtration performance. While our sample size (2 different types of respirators) was small, we did observe a change in electrostatic properties on a filter layer that coincided with the failure on the Quantitative Fit Test.

61 RADIATION PROTECTION AND DOSIMETRY↗

System and method for measuring fluid properties using magnetic field techniques via magnetic tracer

A method and apparatus for determining a property of a fluid in a vessel. The method uses magnetic tracer particles and an externally applied magnetic field which orients the particles. When the fluid moves, it changes the orientation of the tracer particles, thus changing the magnetic fields. These changes are detected by external magnetic field sensors. By using mathematical models, the property of the fluid in the vessel is determined from the detected magnetic field. In this manner, fluid vorticity, velocity, strain and stress may be estimated.

42 ENGINEERING↗

Flows of Wet Foamsand Concentrated Emulsions

The aim of this project was is to advance a microstructural understanding of foam and emulsion flows. The dynamics of individual surfactant-covered drops and well as the collective behavior of dilute and concentrated was explored using numerical simulations. The long-range goal of this work is the formulation of reliable microphysically-based statistical models of emulsion flows.

Nemer, Martin B.↗