Search NASA⌕ Search

Engineering topics

Netepenko, A.

Publications and source records attributed to Netepenko, A..

At least 19 records

Excellent performance of 650 MHz single-cell niobium cavity after electropolishing

Electropolishing process and cathodes have undergone modification and optimization for both low- and high-beta 650 MHz five-cell niobium cavities for PIP-II. Cavities treated with these modified electropolishing conditions exhibited smooth surfaces and good performance in baseline tests. Nonetheless, due to administrative constraints on project cavities, maximum gradient performance testing was not conducted. This paper presents a study conducted on a single-cell 650 MHz cavity utilizing the optimized electropolishing conditions, highlighting the maximum performance attained for this specific cavity. The cavity tested at 2 K in a vertical cryostat reached a superior accelerating field gradient of 53.3 MV/m at Q0 of 1.6x1010, which is the highest gradient attained for this type of large-sized cavities.

43 PARTICLE ACCELERATORS↗

Direct measurement of microwave loss in Nb films for superconducting qubits

Niobium films are a key component in modern two-dimensional superconducting qubits, yet their contribution to the total qubit decay rate is not fully understood. The presence of different layers of materials and interfaces makes it difficult to identify the dominant loss channels in present two-dimensional qubit designs. In this paper, we present the study that directly correlates measurements of RF losses in such films to material parameters by investigating a high-power impulse magnetron sputtered (HiPIMS) film atop a three-dimensional niobium superconducting radio frequency (SRF) resonator. By using a 3D SRF structure, we are able to isolate the niobium film loss from other contributions. Our findings indicate that microwave dissipation in the HiPIMS-prepared niobium films, within the quantum regime, resembles that of record-high intrinsic quality factor of bulk niobium SRF cavities, with lifetimes extending into seconds. Microstructure and impurity level of the niobium film do not significantly affect the losses. These results set the scale of microwave losses in niobium films and show that niobium losses do not dominate the observed coherence times in present two-dimensional superconducting qubit designs, instead highlighting the dominant role of the dielectric oxide in limiting the performance. We can also set a bound for when niobium film losses will become a limitation for qubit lifetimes.

Abdisatarov, B.↗

Towards the first high-Q treatments for 800 MHz 5-cell elliptical cavities

High-efficiency, high-velocity, sub-GHz elliptical superconducting RF cavities are a critical enabling technology for multiple upcoming accelerator development projects such as for the Powerful Energy Recovery Linac for Experiments (PERLE), and for the Future Circular Collider s (FCC) Booster, and future realizations of its Collider ring. The ambitious quality factor and gradient requirements of these applications require strong SRF R&D programs aimed at developing and optimizing advanced surface processing techniques for 800 MHz cavities. We report the initiation of the 800 MHz R&D program at Fermilab, with the aim of developing high-performance cavities compatible with PERLE and FCC applications.

McGee, K.↗

Transfer of EP and Doping Technology for PIP-II HB650 Cavities from Fermilab to Industry

Fermilab has optimized the surface processing conditions for PIP-II high beta 650 MHz cavities. This encompasses conditions for bulk electropolishing, heat treatment, nitrogen doping, post-doping final electropolishing, and post-processing surface rinsing. The technology has been effectively transitioned to industry. This paper highlights the efforts made to fine-tune the process and to smoothly share them with the partner labs and an associated vendor.

Chouhan, V.↗

High Q SRF cavity-based searches for beyond the standard model physics

The SRF technology developed for accelerators can be successfully applied to new applications, including quantum computing, dark matter searches and beyond the standard model physics. The ultra-high quality factor of SRF cavities can enable unprecedented sensitivity in fields outside of the usual accelerator applications, for examples fundamental and beyond the standard model physics. Applications of SRF cavities for gravitational waves searches are also being investigated. The SQMS Physics and Sensing thrust is working on this effort as it strives to combine SRF cavities with QIS, with a focus on BSM and fundamental physics.

Berlin, A.↗

Nb SRF cavities applied to searches for beyond the standard model physics

The SRF technology developed for accelerators can be successfully applied to new applications, including quantum computing, dark matter searches and beyond the standard model physics. The ultra-high quality factor of SRF cavities can al-low to achieve unprecedented sensitivity in fields outside of the usual accelerator applications, for examples fundamental and beyond the standard model physics. Applications of SRF cavities for gravitational waves searches are also being investigated. The SQMS Physics and Sensing thrust is working on this effort as it strives to combine SRF cavities with QIS, with a focus on BSM and fundamental physics. Using Nb SRF cavities, we run a proof of principle search for the dark photon dark matter candidate at fixed frequency demonstrating the deepest sensitivity to wavelike dark mater [1]. The Dark SRF experiment uses two 1.3GHz SRF cavities to conduct a light shining through wall (LSW) experiment to attempt producing and detecting dark photons in the laboratory. The results of this first superconducting LSW search were recently published [2] and we are now working on the second phase of the experiment, which will be run in a dilution refrigerator using 2.6GHz SRF cavities. In addition to the limits we have achieved, we will also present the experiments we are currently developing, such as the heterodyne axion DM search [3, 4], the SERAPH series of experiments, and gravitational waves searches based on SRF cavities as proposed in [5-8].

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Commissioning of SRF Cavity Analyzer System

Research and development in Superconducting Radio Frequency (SRF) cavities manufacturing, surface treatment, preparation, and doping techniques for the improvement of cavities performance necessitate reliable cavities’ intrinsic quality factor measurement with accurate and repeatable results. Fermilab Vertical Test Stand facility (VTS) performs ~270 cavities tests per year, including R&D cavities as well as production cavities at each step of their preparation for the placement in accelerator’s cryomodules. Current Fermilab VTS testing system is based on the scalar approach of power measurement, which neglects potential error factors of the RF networks with distributed parameters, hence the assessed measurement errors of such a system might be slightly underestimated. Alternative approach, utilizing a vector measurement (amplitude and phase) of RF signals in the setup with a cavity as a device under test, promises an enhanced accuracy and results traceability. New cavity an alyser system based on this approach (Vector VTS) was developed by D. Frolov et al. and currently undergoes a commissioning process. Basic underlying principles of the system will be presented with the methods of quality factor extraction from S-parameters measurement of multiport cavities and brief error analysis will be discussed. The system architecture will be shown with main components parameters and ensuing testing capabilities. Multiple tests results will be discussed with a cross-check comparison of the results obtained with a conventional testing method. System advantages such as automated calibration process and additional features as a built- in microphonics measurement capability will be presented.

Netepenko, A.↗

PI Loop Resonance Control for Dark Photon Experiment at 2 K Using a 2.6 GHz SRF Cavity

Two 2.6 GHz SRF cavities are being used for a dark photon search at the vertical test stand (VTS) in FNAL, for the second phase of the Dark SRF experiment. During testing at 2 K the cavities experience frequency detuning caused by microphonics and slow frequency drifts. The experiment requires that the two cavities have the same frequency within the cavity's bandwidth. These two cavities are equipped with frequency tuners consisting of three piezo actuators. The piezo actuators are used for fine-fast frequency tuning. A proportional-integral (PI) loop utilizing the three piezos on the emitter was used to stabilize the cavity frequency and match the receiver cavity frequency. The results from this implementation will be discussed. The integration time was also calculated via simulation.

43 PARTICLE ACCELERATORS↗

Flux Expulsion and Material Properties of Niobium Explored in 644-650 MHz Cavities

Upcoming projects requiring high-Q ~650 MHz medium-to-high-${\beta}$ elliptical cavities drive a need to understand magnetic RF loss mechanisms and mitigations in greater detail. High-temperature annealing and fast-cooldowns have proven effective techniques for promoting magnetic flux expulsion in cavities, however the extent of their effectiveness has been observed to vary between niobium material lot and vendor. We explore the fast-cooldown method, and high-temperature annealing (900{\deg}C) in 644-650 MHz cavities fabricated from two different niobium vendors: Tokyo-Denkai, and Ningxia. which promote flux-expulsion efficiency. Using EBSD and PPMS methods, we aim to trace cavity flux expulsion efficiency to specific, measurable properties of the bulk niobium material, which, if identified, can lead to methods by which the flux expulsion properties of Nb material can be predicted prior to cavity fabrication, and can enable fine-tuning of cavity temperature treatments.

43 PARTICLE ACCELERATORS↗

Flux expulsion and material properties of Nb

Upcoming projects requiring high-Q ~650 MHz medium-to-high-! elliptical cavities drive a need to understand magnetic RF loss mechanisms and mitigations in greater detail. We explore the fastcooldown method, and high-temperature annealing (900°C) in 644- 650 MHz SRF cavities fabricated from two different niobium vendors: Tokyo-Denkai (TD), and Ningxia (NX). Using EBSD and PPMS methods, we aim to trace cavity flux expulsion efficiency to specific, measurable properties of the bulk niobium material, which, if identified, can lead to methods by which the flux expulsion properties of Nb material can be predicted prior to cavity fabrication.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

AMR Magnetic Sensors in Flux Expulsion Studies

Magnetic flux expulsion properties of the superconducting material such as bulk niobium, widely used for the radio-frequency cavity fabrication, substantially affect the performance characteristics of the cavities. The quality factor of the SRF resonators can be significantly compromised due to the presence of the trapped flux vortices causing additional RF energy losses in the material. Large number of experiments have been carried out by different research groups to establish the correlation of the flux trapping in niobium cavities with the presence of impurities in niobium as well as various surface treatment methods. Majority of these experiments utilize commercially available cryogenic fluxgate magnetic sensors to measure the field before and after the niobium transition to the superconducting state to quantify the amount of flux trapped. One disadvantage of the typically used fluxgates is the size of the sensing volume. As an example, the Barting-ton F and G type cryogenic fluxgates have a sensing core length of about 30mm, which is comparable to the curvature radius of the cavity walls and hence the magnetic field lines curvature radius after the expulsion. Thus, the measured field value needs to be corrected to account for the sensor effective averaging over the sensing volume. In case of the sharper geometries, for instance if the flux expulsion to be measured on the edge of the rectangular niobium flat sheet with a thickness of ~5mm, the use of the fluxgate would be impractical.

Netepenko, A.↗