Reactivity Coefficient Measurements and Sensitivity Studies [Abstract]

Nuclear data validation is often performed today using criticality measurements. The gold standard for criticality measurements is the International Criticality Safety Benchmark Experiment Project (ICSBEP). The validation specifically focuses on the effective multiplication factor (k eff ). K eff is a relatively easy parameter to infer and has reduced uncertainty due to being at or above critical. However, while k eff is a well-documented parameter with detailed sensitivity and uncertainty analysis, it cannot be used as a standalone metric to determine inaccuracies in nuclear data (e.g., cross section data, PFNS, nu), which is based on theory, physics, and differential measurements. The Experiments Underpinned by Computational Learning for Improvements in nuclear Data (EUCLID) project aims to identify compensating errors in specific nuclear data by optimally designing experiments that are sensitive to a suite of measurement parameters beyond k eff . By identifying how each parameter's nuclear data sensitivity differs from others, experiments can be designed to constrain questionable nuclear data. One sensitivity that is of particular interest to this project includes reactivity coefficient sensitivities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigating Fission Reaction Rate Ratio Sensitivities [Abstract]

Reaction rate ratios are a measurable parameter for reactor and criticality applications. A number of foil irradiations and fission chamber measurements have been performed for critical assemblies at Los Alamos National Laboratory starting in the 1950’s including (i) Godiva, a bare HEU spherical assembly; (ii) Flattop-25, a spherical assembly consisting of an HEU core and a natural uranium reflector; (iii) Jezebel, a bare 239 Pu assembly; and (iv) Flattop-Pu, a spherical assembly consisting of a 239Pu core and a natural uranium reflector. Fission ratio data for 238 U(n,f)/ 235 U(n,f), 237 Np(n,f)/ 235 U(n,f), 233 U(n,f)/ 235 U(n,f) and 239 Pu(n,f)/ 235 U(n,f) were obtained and reported. The EUCLID (Experiments Underpinned by Computational Learning for Improvements in nuclear Data) project at Los Alamos National Laboratory (LANL) aims to constrain nuclear data by using a suite of measurement types beyond k-effective. Recent investigations include the use of pulsed spheres for nuclear data validation and other measurement methods of interest. One focus of the work is to determine if other methods are complimentary to the critical experiments utilized for nuclear data validation. It is anticipated the investigations will help inform methods that may be utilized in machine learning algorithms for nuclear validation. In order to use a measurement type for nuclear validation, it is necessary to obtain cross-section sensitivities for parameters. This work looks at reaction rate ratio sensitivities with SENSMG and Monte Carlo N-Particle R Code Version 6.21.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Including 238 U(n,f)/ 235 U(n,f) and 239 Pu(n,f)/ 235 U(n,f) NIFFTE fission TPC Cross-sections into the Neutron Data Standards Database

The primary purpose of this report is to document how the 238 U/ 235 U and 239 Pu/ 235 U neutron induced fission cross-section ratios, 238 U(n,f)/ 235 U(n,f) and 239 Pu(n,f)/ 235 U(n,f), respectively, measured by the NIFFTE fission Time Projection Chamber (fissionTPC) were included in the most recent database (termed GMA) underlying Neutron Data Standards (NDS) evaluations. This report shows and discusses NDS input files, and underlying assumptions regarding the uncertainty estimate and necessary for including these data. This uncertainty estimate and the resulting files were based on information provided by fissionTPC experimentalists, R.J.Casperson, N.S. Bowden, L. Snyder and K.T. Schmitt for the 238 U ratio, and by L. Snyder for the 239 Pu ratio. The fissionTPC data were included twice, by D. Neudecker and V. Pronyaev, to counter-check results and exclude possible mistakes in their inclusion. It is shown in both evaluations that including fissionTPC 239 Pu(n,f)/ 235 U(n,f) data points to a lower evaluated 239 Pu(n,f) cross section above 10 MeV than the currently released NDS data. This raises the question whether a part of a previous dataset by Tovesson et al., that was previously rejected above 13 MeV for having low values, should be included in the NDS evaluation after all. The evaluated 238 U(n,f) cross section only changes significantly close to the threshold. The impact on the 235 U(n,f) cross section is minimal. fissionTPC data reduce evaluated uncertainties on both observables by 0–12% of the GMA evaluated uncertainties. However, the currently released NDS data contain in addition to these GMA evaluated uncertainties “Unrecognized Sources of Uncertainties” (USU) of 1.2%. It needs to be further discussed within the NDS project, whether the new fissionTPC data should also reduce USU.

238U(n,f)/235U(n,f)↗

Validation testing of 239 Pu IAEA INDEN, LANL and LLNL 239 Pu files from May 2022 [Slides]

239 Pu files validated: ENDF/B-VIII.0, ENDF/B-VIII.0 except for 239 Pu from INDEN (p49) which performs the same in crit testing as (p53), ENDF/B-VIII.0 except for 239 Pu from INDEN (p51), ENDF/B-VIII.0 except for 239 Pu from LANL (4/21), ENDF/B-VIII.0 except for 239 Pu from LLNL (5/16); tweaked nu-bar, ENDF/B-VIII.0 except for 239 Pu from LLNL (5/1)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validating FENDL-2.1 and FENDL-3.2 with a Suite of LLNL Pulsed Sphere Measurements

This report summarizes simulations of LLNL pulsed-sphere neutron-leakage spectra using FENDL- 3.2, an upcoming version of the Fusion Evaluated Nuclear Data Library, and one of its predecessor libraries, FENDL-2.1. These simulated values are compared to values obtained with the recent U.S. nuclear data library, ENDF/B-VIII.0, and its predecessor, ENDF/B-VII.1 as well as experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of the U 235 ( n , f ) prompt fission neutron spectrum from 10 keV to 10 MeV induced by neutrons of energy from 1 MeV to 20 MeV

The characterization of fission-driven nuclear systems primarily relies on calculations of neutron-induced chain reactions, and these calculations require evaluated nuclear data as input. Calculation accuracy heavily depends on input nuclear data evaluation accuracy, and thus high precision on the experimental input to the nuclear data evaluation is essential for fundamental quantities like the energy spectrum of neutrons emitted from neutron-induced fission (i.e., the prompt fission neutron spectrum, PFNS). Despite decades of measurement efforts, prior to the measurements described in this work there were only three literature data sets for the 235 U(n,f) PFNS at incident neutron energies above 1.0 MeV considered reliable for inclusion in nuclear data evaluations and no reliable data sets above 3.0 MeV incident neutron energy. In this work we report on new measurements of the 235 U(n,f) PFNS spanning a grid of 1.0–20.0 MeV in incident neutron energy and 0.01–10.0 MeV in outgoing (PFNS) neutron energy. These measurements were carried out at the Weapons Neutron Research facility at the Los Alamos Neutron Science Center and used a multifoil parallel-plate avalanche counter target with both a Li-glass and a liquid scintillator detector array in separate experiments to span the quoted outgoing neutron energy ranges. The PFNS results are shown in terms of the energy spectra themselves as well as the average PFNS energy $(\langle{E}\rangle)$ and ratios of $\langle{E}\rangle$ at forward and backward angles. Here, the results are compared with literature data and selected nuclear data evaluations. Generally, the data agree with the ENDF/B-VIII.0 evaluation below 5.0-MeV incident neutron energy and more closely with the JEFF-3.3 evaluation above 5.0 MeV, though no evaluations considered for comparison in this work agree with the data across all of the incident and outgoing neutron energies shown, especially in regions where the third-chance fission process becomes available. Additionally, we show a ratio of the present PFNS results for 235 U(n, f) with a recent and highly correlated experiment to measure the 239 Pu(n, f) PFNS at the same experimental facility and with nearly identical equipment and analysis procedures. Many observations reported in this work are the first of their kind and represent significant advancements for knowledge of the 235 U(n, f) PFNS.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Release of Evaluated 235 U(n,f) Average Prompt Fission Neutron Multiplicities Including the CGMF Model

This report documents an evaluation of the average prompt fission neutron multiplicity, $\overline{v}_p$, of 235 U from 200 keV to 15 MeV that is a potential release candidate for the upcoming U.S. nuclear data library, ENDF/B-VIII.1. This evaluation had to be re-done from "scratch", as the input to the $\overline{v}_p$ evaluation of the previous library, ENDF/B-VIII.0, was lost. That means that all available experimental data were re-analyzed and uncertainties were re-estimated. Another major difference to ENDF/B-VIII.0 is that this evaluation includes model information from the Hauser-Feshbach fission fragment decay code CGMF, while ENDF/B-VIII.0 is based purely on experimental data. CGMF links several fission quantities with each other; $\overline{v}_p$ is predicted by assumptions made on, e.g., pre-neutron emission yields as a function of mass, the total kinetic energy, or spin and parity of fission fragments. This allows to perform two types of validation for the new 235 U $\overline{v}_p$: On the one hand, one can employ evaluated CGMF parameters obtained from fitting to experimental 235 U $\overline{v}_p$ to predict yields as a function of mass, the average total kinetic energy, or the mean energy of the prompt fission neutron spectrum. These model-predicted values can then be compared to experimental and evaluated data. The model-predicted fission-observable values using evaluated parameters obtained here are reasonably close to experimental data indicating the evaluated 235 U(n,f) $\overline{v}_p$ are physical. On the other hand, one can validate 235 U $\overline{v}_p$ with respect to integral responses such as fast ICSBEP critical assemblies or LLNL pulsed spheres. LLNL pulsed-sphere neutron-leakage spectra are minimally impacted by the new 235 U $\overline{v}_p$ as these experimental data are shape data and the $\overline{v}_p$ would mostly lead to a change in normalization of the data as the spheres are relatively thin (0.7 and 1.5 mean-free path) and, thus, mostly depend on 235 U $\overline{v}_p$ from 12-15 MeV. The change in the predicted effective neutron multiplication factor, k eff , of selected ICSBEP critical assemblies, however, is large compared to values using ENDF/B-VIII.0 and experimental k eff : The average bias is 108 pcm across all studied k eff values versus 12 pcm for ENDF/B-VIII.0. A reasonable performance in simulating keff (mean bias of 14 pcm) can be retained by tweaking 235 U $\overline{v}_p$ from 3-5 MeV, and combining it with a recent 235 U PFNS evaluation that is also a ENDF/B-VIII.1 release candidate.

235U↗

Including Chi-Nu 235 U PFNS Experimental Data into an ENDF/B-VIII.1 Release Candidate Evaluation

This report documents an evaluation of 235 U prompt fission neutron spectra (PFNS) that is a release candidate for the upcoming U.S. nuclear data library, ENDF/B-VIII.1. This evaluation differs from its predecessor, ENDF/B-VIII.0, mainly by the inclusion of 235 U PFNS measured by the Chi-Nu team of LANL and LLNL. This data set is the first one that covers the 235 U PFNS for continuous incident-neutron energies of 1⁻20 MeV and outgoing-neutron energies from 10 keV⁻10 MeV with high precision. Previous data sets were either measured in a limited energy range or with less precision. Hence, these new Chi-Nu data provide decisive information for the evaluation. The resulting evaluated data correspond well to the new experimental PFNS. The evaluated PFNS also produce average mean energies and 239 Pu/ 235 U PFNS in agreement with associated Chi-Nu data. If one uses the new evaluated data to predict the neutron multiplication factor, k eff , of selected ICSBEP critical assemblies, the differences of simulated values compared to those using ENDF/B-VIII.0 is modest (less than 55 pcm). This difference in k eff can be easily accommodated by changes in the 235 U average prompt fission neutron multiplicity that is currently being re-evaluated. In addition to that, the new PFNS predict on average 235 U LLNL pulsed-sphere neutron-leakage spectra better than ENDF/B-VIIII.0 PFNS.

235U↗

EUCLID Sensitivity Database

This report documents the EUCLID sensitivity database along with its several use-cases. EUCLID computed sensitivities for the following integral responses: Criticality of ICSBEP critical assemblies, LLNL pulsed-sphere neutron-leakage spectra, reaction rates in selected ICBSEP critical assemblies, delayed neutron factions of selected ICSBEP critical assemblies, reactivity coefficients in two ICSBEP critical assemblies, sub-critical assembly responses and Rossi-alpha of selected critical assemblies. It is described for each response what the reported observable constitutes, the method we used to obtain the sensitivities, and which integral experiments were studied. It is also documented briefly in what format these sensitivities are stored. These sensitivities were used for many aspects of the EUCLID project, like ML-supported large-scale nuclear-data validation, or optimization of integral experiments. But these sensitivities can also be applied for more established processes in the nuclear-data application field such as adjustment or assessing the upper sub-critical limit.

Delayed Neutron Fraction↗

Test Results for Checking Reliability of Selected ENDF/B-VIII.0 Evaluated Uncertainties

This report summarizes error messages obtained from counter-checking whether 1 H, 9 Be, 12 C, 27 Al, 235,238 U and 238–242 Pu relative uncertainties of ENDF/B-VIII.0 are realistic. Large parts of this report were generated automatically by the code CovVal. This code allows to test the reliability of relative uncertainties of any isotope. It gives generic error and warning messages if evaluated relative uncertainties of a particular reaction are likely under- or over-estimated. In addition to these error and warning messages, I added comments whether the flagged uncertainties are truly under- or overestimated. I call out these uncertainties that should be further investigated and corrected by an evaluator for an upcoming release of ENDF/B-VIII.1.

07 ISOTOPE AND RADIATION SOURCES↗

Modeling and evaluating 239 Pu and 235 U PFNS and average prompt-neutron multiplicity [Slides]

The following are currently in VIII.1 LANL and IAEA test files: 239 Pu nu-bar including CGMF modeling and CEA data, 239 Pu PFNS including Chi-Nu & CEA data, 239 Pu(n,f) cross section including fission TPC data. The following are currently being tested: 235 U nu-bar including CGMF modeling and 235 U PFNS including Chi-Nu data. Upcoming tasks include the correction of 235 U Chi-Nu PFNS at higher E inc , benchmarking 235 U PFNS and nu-bar evaluations, and getting 238 U nu-bar.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

EUCLID: Experiments Underpinned by Computational Learning for Improvements in Nuclear Data [Slides]

EUCLID will design validation experiments optimized to resolve compensating errors and adjust nuclear data to experiments. A big part of the success of the EUCLID proposal was due to previous work supported by NCSP (MCNP, nuclear data, and NCERC capabilities). The work performed under EUCLID will similarly benefit the NCSP mission. It will lead to new MCNP capabilities, improved nuclear data and nuclear data capabilities, and new methodology and tools that will have large impact on future NCERC experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Definitions for Testing Whether Evaluated Nuclear Data Relative Uncertainties are Realistic in Size

This document describes various tests that can be used to check whether evaluated relative uncertainties stored in nuclear-data covariances are realistic. To be more specific, these tests check whether nuclear-data uncertainties could be either over- or under-estimated given the input that usually enters the evaluation of nuclear-data mean values and covariances. Warning and error messages on the reliability of nuclear-data uncertainties will result from these tests. If uncertainties of one specific nuclear-data observable trigger warning messages from multiple tests, an evaluator should counter-check the reliability of the relative uncertainties of this particular nuclear-data covariance matrix.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of Delayed Neutron Sensitivities for Several ICSBEP Benchmarks using MCNP

The effective delayed neutron (β$_{eff}$) is a very important parameter for reactor and criticality applications. This parameter is equal to the difference in reactivity between delayed critical ($k_{eff}$ = 1, which requires both prompt and delayed neutrons to achieve criticality) and prompt critical ($k_p$ = 1, which requires only prompt neutrons to achieve criticality). This is often referred to as the delayed critical "window" (the region of criticality between delayed and prompt critical). β$_{eff}$ is a reactor kinetics parameters and depends on the nuclides in the system that undergo fission as well as the spectral characteristics of the system. Measurements of β$_{eff}$ have been performed for many criticality experiments. The EUCLID (Experiments Underpinned by Computational Learning for Improvements in nuclear Data) project at Los Alamos National Laboratory (LANL) aims to constrain nuclear data by using a suite of measurement types beyond $k_{eff}$. Our team has recently investigated the use of pulsed spheres for nuclear data validation. Several other measurement methods are also of interest, including β$_{eff}$ (investigated here) and reactivity coefficients (investigated in a separate work at this same meeting). One focus of our work is to determine if other methods are complimentary to the critical experiments already utilized for nuclear data validation. This is important because if a method has similar sensitivities then it will not be particularly useful for nuclear data validation as it will provide the same information as the critical experiments already being used. Here "similar" could refer to several characteristics, one being the shape of a sensitivity profile over energy. In the future, these methods will be utilized (with both existing and new experiments) in machine learning algorithms for nuclear validation, similar to what is currently done for criticality experiments. In order to use a measurement type for nuclear validation, it is necessary to obtain cross-section sensitivities for that parameter. This work looks at one approach to estimate β$_{eff}$ sensitivities by utilizing $k_{eff}$ sensitivities within Monte Carlo N-Particle ® Code Version 6.2. This is applied to several criticality benchmarks. Results are compared and the benefits and limitations of this approach are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗