Search NASA⌕ Search

Engineering topics

Newby, N.

Publications and source records attributed to Newby, N..

Evaluation of Mid-Size Male Hybrid III Models for use in Spaceflight Occupant Protection Analysis

Introduction: In an effort to improve occupant safety during dynamic phases of spaceflight, the National Aeronautics and Space Administration (NASA) has worked to develop occupant protection standards for future crewed spacecraft. One key aspect of these standards is the identification of injury mechanisms through anthropometric test devices (ATDs). Within this analysis, both physical and computational ATD evaluations are required to reasonably encompass the vast range of loading conditions any spaceflight crew may encounter. In this study the accuracy of publically available mid-size male HIII ATD finite element (FE) models are evaluated within applicable loading conditions against extensive sled testing performed on their physical counterparts. Methods: A series of sled tests were performed at the Wright Patterson Air force Base (WPAFB) employing variations of magnitude, duration, and impact direction to encompass the dynamic loading range for expected spaceflight. FE simulations were developed to the specifications of the test setup and driven using measured acceleration profiles. Both fast and detailed FE models of the mid-size male HIII were ran to quantify differences in their accuracy and thus assess the applicability of each within this field. Results: Preliminary results identify the dependence of model accuracy on loading direction, magnitude, and rate. Additionally the accuracy of individual response metrics are shown to vary across each model within evaluated test conditions. Causes for model inaccuracy are identified based on the observed relationships. Discussion: Computational modeling provides an essential component to ATD injury metric evaluation used to ensure the safety of future spaceflight occupants. The assessment of current ATD models lays the groundwork for how these models can be used appropriately in the future. Identification of limitations and possible paths for improvement aid in the development of these effective analysis tools.

Putnam, J.↗

Suited and Unsuited Hybrid III Impact Testing and Finite Element Model Characterization

NASA spacecraft design requirements for occupant protection are a combination of the Brinkley Dynamic Response Criteria and injury assessment reference values (IARV) extracted from anthropomorphic test devices (ATD). For the ATD IARVs, the requirements specify the use of the 5th percentile female Hybrid III and the 95th percentile male Hybrid III. Each of these ATDs is required to be fitted with an articulating pelvis (also known as the aerospace pelvis) and a straight spine. The articulating pelvis is necessary for the ATD to fit into spacecraft seats, while the straight spine is required as injury metrics for vertical accelerations are better defined for this configuration. Sled testing of the Hybrid III 5th Percentile Female Anthropomorphic Test Device (ATD) was performed at Wright-Patterson Air Force Base (WAPFB). Two 5th Percentile ATDs were tested, the Air Force Research Lab (AFRL) and NASA owned Hybrid III ATDs with aerospace pelvises. Testing was also conducted with a NASA-owned 95th Percentile Male Hybrid III with aerospace pelvis at WPAFB. Testing was performed using an Orion seat prototype provided by Johnson Space Center (JSC). A 5-point harness comprised of 2 inch webbing was also provided by JSC. For suited runs, a small and extra-large Advanced Crew Escape System (ACES) suit and helmet were also provided by JSC. Impact vectors were combined frontal/spinal and rear/lateral. Some pure spinal and rear axis testing was also performed for model validation. Peak accelerations ranged between 15 and 20-g. This range was targeted because the ATD responses fell close to the IARV defined in the Human-Systems Integration Requirements (HSIR) document. Rise times varied between 70 and 110 ms to assess differences in ATD responses and model correlation for different impact energies. The purpose of the test series was to evaluate the Hybrid III ATD models in Orion-specific landing orientations both with and without a spacesuit. The results of these tests were used by the NASA Engineering and Safety Center (NESC) to validate the finite element model (FEM) of the Hybrid III 5th Percentile Female ATD. Physical test data was compared to analytical predictions from simulations, and modelling uncertainty factors have been determined for each injury metric. Additionally, the test data has been used to further improve the FEM, particularly in the areas of the ATD preload, harness, and suit and helmet effects.

Lawrence, C.↗

Data Mining of Historical Human Data to Assess the Risk of Injury due to Dynamic Loads

The NASA Occupant Protection Group is charged with ensuring crewmembers are protected during all dynamic phases of spaceflight. Previous work with outside experts has led to the development of a definition of acceptable risk (DAR) for space capsule vehicles. The DAR defines allowable probability rates for various categories of injuries. An important question is how to validate these probabilities for a given vehicle. One approach is to impact test human volunteers under projected nominal landing loads. The main drawback is the large number of subject tests required to attain a reasonable level of confidence that the injury probability rates would meet those outlined in the DAR. An alternative is to mine existing databases containing human responses to impact. Testing an anthropomorphic test device (ATD) at the same human‐exposure levels could yield a range of ATD responses that would meet DAR. As one aspect of future vehicle validation, the ATD could be tested in the vehicle's seat and suit configuration at nominal landing loads and compared with the ATD responses supported by the human data set. This approach could reduce the number of human‐volunteer tests NASA would need to conduct to validate that a vehicle meets occupant protection standards. METHODS: The U.S. Air Force has recorded hundreds of human responses to frontal, lateral, and spinal impacts at many acceleration levels and pulse durations. All of this data are stored on the Collaborative Biomechanics Data Network (CBDN), which is maintained by the Wright Patterson Air Force Base (WPAFB). The test device for human occupant restraint (THOR) ATD was impact tested on WPAFB's horizontal impulse accelerator (HIA) matching human‐volunteer exposures on the HIA to 5 frontal and 3 spinal loading conditions. No human injuries occurred as a result of these impact conditions. Peak THOR response variables for neck axial tension and compression, and thoracic‐spine axial compression were collected. Maximal chest deflection was determined from motion capture video of the impact test. HIC‐ 15 and BRIC were calculated from head acceleration responses. Given the number of human subjects for each test condition a confidence interval of injury probability will be obtained. RESULTS: Results will be discussed in terms of injury‐risk probability estimates based on the human data set evaluated. Also, gaps in the data set will be identified. These gaps could be one of two types. One is areas where additional THOR testing would increase the comparable human data set, thereby improving confidence in the injury probability rate. The other is where additional human testing would assist in obtaining information on other acceleration levels or directions. DISCUSSION: The historical human data showed validity of the THOR ATD for supplemental testing. The historical human data are limited in scope, however. Further data are needed to characterize the effects of sex, age, anthropometry, and deconditioning due to spaceflight on risk of injury

Wells, Jesica↗

Assessing the Risk of Crew Injury Due to Dynamic Loads During Spaceflight

Spaceflight requires tremendous amounts of energy to achieve Earth orbit and to attain escape velocity for interplanetary missions. Although the majority of the energy is managed in such a way as to limit the accelerations on the crew, several mission phases may result in crew exposure to dynamic loads. In the automotive industry, risk of serious injury can be tolerated because the probability of a crash is remote each time a person enters a vehicle, resulting in a low total risk of injury. For spaceflight, the level of acceptable injury risk must be lower to achieve a low total risk of injury because the dynamic loads are expected on each flight. To mitigate the risk of injury due to dynamic loads, the NASA Human Research Program has developed a research plan to inform the knowledge gaps and develop relevant tools for assessing injury risk. The risk of injury due to dynamic loads can be further subdivided into extrinsic and intrinsic risk factors. Extrinsic risk factors include the vehicle dynamic profile, seat and restraint design, and spacesuit design. Human tolerance to loads varies considerably depending on the direction, amplitude, and rise-time of acceleration therefore the orientation of the body to the dynamic vector is critical to determining crew risk of injury. Although a particular vehicle dynamic profile may be safe for a particular design, the seat, restraint, and suit designs can affect the risk of injury due to localized effects. In addition, characteristics intrinsic to the crewmember may also contribute to the risk of injury, such as crewmember sex, age, anthropometry, and deconditioning due to spaceflight, and each astronaut may have a different risk profile because of these factors. The purpose of the research plan is to address any knowledge gaps in the risk factors to mitigate injury risk. Methods for assessing injury risk have been well documented in other analogous industries and include human volunteer testing, human exposure to dynamic environments, post-mortem human subject (PMHS) testing, animal testing, anthropomorphic test devices (ATD), dynamic models of the human, numerical models of ATDs, and numerical models of the human. Each has inherent strengths and limitations. For example, human volunteer testing is advantageous because a population can be selected that is similar to the astronaut corps; however, because of the inherent ethical limitations, only sub-injurious conditions can be tested. PMHSs can be tested in a variety of conditions including injurious levels, but the responses are not completely analogous to living human subjects. In addition, it is exceedingly difficult to select a PMHS population that is similar to the astronaut corps. ATDs are currently widely used in the automotive industry and military because they are highly repeatable and durable. Unfortunately, because they are mechanical models of the human body, the biofidelity of the responses are limited to dynamic conditions used to validate the ATD. Numerical models of the ATD, in addition to the strengths and limitations for ATDs, are easy to use for a variety of designs before a design is fabricated, but also have additional limitations for ATDs, are easy to use for a variety of designs before a design is fabricated, but also have additional uncertainty. Dynamic models are simple and easy to use, but do not account for localized effects of the seat and suit. Finally, numerical models of the human have the potential to have the most advantages; however, the current models are not validated for the conditions expected during spaceflight. To properly assess spaceflight conditions with numerical human models, human data would be needed to optimize the model responses for those conditions. Using the appropriate assessment method with the knowledge gained for each risk factor, an appropriate approach for mitigating the risk of injury due to dynamic loads can be developed ensuring crew safety in future NASA vehicles.

Somers, J. T.↗

How Well Does the Latest Anthropomorphic Test Device Mimic Human Impact Responses?

One of the goals of the NASA Occupant Protection Group is to understand the human tolerance to dynamic loading. This knowledge has to come through indirect approaches such as existing human response databases, anthropometric test devices (ATD), animal testing, post‐mortem human subjects, and models. This study investigated the biofidelity of the National Highway Traffic Safety Administration's ATD named the THOR (test device for human occupant restraint). If THOR responds comparably to humans, then it could potentially be used as a human surrogate to help validate space vehicle requirements for occupant protection. The THOR responses to frontal and spinal impacts (ranging from 8 to 12 G with rise times of 40, 70, and 100 ms) were measured and compared to human volunteer responses (95 trials in frontal and 58 in spinal) previously collected by the U. S. Air Force on the same horizontal impact accelerator. The impact acceleration profiles tested are within the expected range of multi‐purpose crew vehicle (MPCV) landing dynamics. A correlation score was calculated for each THOR to human comparison using CORA (CORrelation and Analysis) software. A two‐parameter beta distribution model fit was obtained for each dependent variable using maximum likelihood estimation. For frontal impacts, the THOR head x‐acceleration peak response correlated with the human response at 8 and 10‐G 100 ms but not 10‐G 70 ms. The phase lagged the human response. Head z‐acceleration was not correlated. Chest x‐acceleration was in phase, had a higher peak response, and was well correlated with lighter subjects (Cora = 0.8 for 46 kg vs. Cora = 0.4 for 126 kg). Head x‐displacement had a leading phase. Several subjects responded with the same peak displacement but the mean of the group was lower. The shoulder x‐displacement was in phase but had higher peaks than the human response. For spinal impacts, the THOR head x‐acceleration was not well correlated. Head and chest z‐acceleration was in phase but had a higher peak response. Chest z‐acceleration was highly correlated with heavier subjects at lower G pulses (Cora = 0.86 for 125 kg at 8 G). The human response was variable in shoulder z‐displacement but the THOR was in phase and was comparable to the mean peak response. Head xand z‐displacement was in phase but had higher peaks. Seat pan forces were well correlated, were in phase, but had a larger peak response than most subjects. The THOR does not respond to frontal and spinal impacts exactly the same way that a human does. Some responses are well matched and others are not. Understanding the strengths and weaknesses of this ATD is an important first step in determining its usefulness in occupant protection at NASA

Newby, N.↗

ISS Squat and Deadlift Kinematics on the Advanced Resistive Exercise Device

Visual assessment of exercise form on the Advanced Resistive Exercise Device (ARED) on orbit is difficult due to the motion of the entire device on its Vibration Isolation System (VIS). The VIS allows for two degrees of device translational motion, and one degree of rotational motion. In order to minimize the forces that the VIS must damp in these planes of motion, the floor of the ARED moves as well during exercise to reduce changes in the center of mass of the system. To help trainers and other exercise personnel better assess squat and deadlift form a tool was developed that removes the VIS motion and creates a stick figure video of the exerciser. Another goal of the study was to determine whether any useful kinematic information could be obtained from just a single camera. Finally, the use of these data may aid in the interpretation of QCT hip structure data in response to ARED exercises performed in-flight. After obtaining informed consent, four International Space Station (ISS) crewmembers participated in this investigation. Exercise was videotaped using a single camera positioned to view the side of the crewmember during exercise on the ARED. One crewmember wore reflective tape on the toe, heel, ankle, knee, hip, and shoulder joints. This technique was not available for the other three crewmembers, so joint locations were assessed and digitized frame-by-frame by lab personnel. A custom Matlab program was used to assign two-dimensional coordinates to the joint locations throughout exercise. A second custom Matlab program was used to scale the data, calculate joint angles, estimate the foot center of pressure (COP), approximate normal and shear loads, and to create the VIS motion-corrected stick figure videos. Kinematics for the squat and deadlift vary considerably for the four crewmembers in this investigation. Some have very shallow knee and hip angles, and others have quite large ranges of motion at these joints. Joint angle analysis showed that crewmembers do not return to a normal upright stance during squat, but remain somewhat bent at the hips. COP excursions were quite large during these exercises covering the entire length of the base of support in most cases. Anterior-posterior shear was very pronounced at the bottom of the squat and deadlift correlating with a COP shift to the toes at this part of the exercise. The stick figure videos showing a feet fixed reference frame have made it visually much easier for exercise personnel and trainers to assess exercise kinematics. Not returning to fully upright, hips extended position during squat exercises could have implications for the amount of load that is transmitted axially along the skeleton. The estimated shear loads observed in these crewmembers, along with a concomitant reduction in normal force, may also affect bone loading. The increased shear is likely due to the surprisingly large deviations in COP. Since the footplate on ARED moves along an arced path, much of the squat and deadlift movement is occurring on a tilted foot surface. This leads to COP movements away from the heel. The combination of observed kinematics and estimated kinetics make squat and deadlift exercises on the ARED distinctly different from their ground-based counterparts. CONCLUSION This investigation showed that some useful exercise information can be obtained at low cost, using a single video camera that is readily available on ISS. Squat and deadlift kinematics on the ISS ARED differ from ground-based ARED exercise. The amount of COP shift during these exercises sometimes approaches the limit of stability leading to modifications in the kinematics. The COP movement and altered kinematics likely reduce the bone loading experienced during these exercises. Further, the stick figure videos may prove to be a useful tool in assisting trainers to identify exercise form and make suggestions for improvements

Newby, N.↗

Evaluation of the XSENS Force Shoe on ISS

The Advanced Resistive Exercise Device (ARED) offers crewmembers a wide range of resistance exercises but does not provide any type of load monitoring; any load data received are based on crew self-report of dialed in load. This lack of real-time ARED load monitoring severely limits research analysis. To address this issue, portable load monitoring technologies are being evaluated to act as a surrogate to ARED's failed instrumentation. The XSENS ForceShoe"TM" is a commercial portable load monitoring tool, and performed well in ground tests. The ForceShoe "TM" was recently deployed on the International Space Station (ISS), and is being evaluated as a tool to monitor ARED loads.

Hanson, A. M.↗

Validation of the 5th and 95th Percentile Hybrid III Anthropomorphic Test Device Finite Element Model

NASA spacecraft design requirements for occupant protection are a combination of the Brinkley criteria and injury metrics extracted from anthropomorphic test devices (ATD's). For the ATD injury metrics, the requirements specify the use of the 5th percentile female Hybrid III and the 95th percentile male Hybrid III. Furthermore, each of these ATD's is required to be fitted with an articulating pelvis and a straight spine. The articulating pelvis is necessary for the ATD to fit into spacecraft seats, while the straight spine is required as injury metrics for vertical accelerations are better defined for this configuration. The requirements require that physical testing be performed with both ATD's to demonstrate compliance. Before compliance testing can be conducted, extensive modeling and simulation are required to determine appropriate test conditions, simulate conditions not feasible for testing, and assess design features to better ensure compliance testing is successful. While finite element (FE) models are currently available for many of the physical ATD's, currently there are no complete models for either the 5th percentile female or the 95th percentile male Hybrid III with a straight spine and articulating pelvis. The purpose of this work is to assess the accuracy of the existing Livermore Software Technology Corporation's FE models of the 5th and 95th percentile ATD's. To perform this assessment, a series of tests will be performed at Wright Patterson Air Force Research Lab using their horizontal impact accelerator sled test facility. The ATD's will be placed in the Orion seat with a modified-advanced-crew-escape-system (MACES) pressure suit and helmet, and driven with loadings similar to what is expected for the actual Orion vehicle during landing, launch abort, and chute deployment. Test data will be compared to analytical predictions and modelling uncertainty factors will be determined for each injury metric. Additionally, the test data will be used to further improve the FE model, particularly in the areas of the ATD neck components, harness, and suit and helmet effects.

Lawrence, C.↗

Effects of Daily Centrifugation on Segmental Fluid Distribution in Bed-rested Subjects

The effect of daily centrifugation on segmental fluid distribution have been studied during 21 days of 6 degree head down bedrest. One group (N=7) underwent no countermeasure while the other (N=8) received a daily, one hour, dose (2.5 gz at the foot, decreasing to 1.0 gz at the heart) of artificial gravity (AG) training on the Johnson Space Center short radius centrifuge. Fluid shifts of thoracic(VTO), abdominal (VAB), thigh (VTH), and calf (VCA) regions were measured by the tetrapolar segmental body impedance technique. Untrained subjects reduced their total volume from 18.9 plus or minus 0.5L to 17.9 plus or minus 0.9L (MN plus or minus SE, P less than 0.05) while trained subjects maintained their total volume. In untrained, control, subjects after bed rest, there was a trend toward reduced volume in all segments, with significant reductions in thigh and calf (fig, P less than 0.05). Trained subjects maintained volume in all segments. Our data indicate that artificial gravity treatment counteracts bed rest-induced hypovolemia.

Diedrich, Andre↗