Multiwavelength pyrometry for nongray bodies
A multiwavelength technique was developed and applied to measure the temperatures of nongray surfaces. The instruments required are a spectral radiometer, a dedicated auxiliary radiation source, and a computer. In general, three radiation spectra are recorded: (1) spectrum S sub 0 of the auxiliary radiation source; (2) spectrum S sub 1 of the surface-emitted radiation; and (3) spectrum S sub 2, the sum of the radiation of S sub 1 plus the reflected radiation due to the incidence of the auxiliary radiation source on the surface. Subtracting spectrum S sub 1 from spectrum Sub 2 yields the reflection spectrum resulting from the incidence radiation. From these spectra, a quantity z(lambda) is derived and is related to the reflectivity r(lambda) by r(lambda) = z(lambda)/f, where f is a constant. Spectrum S sub 1 is represented mathematically as the product of a wavelength-dependent emissivity obtained from Kirchhoff's law and a Planck function of temperature T. Application of two-variable (lambda and z), nonlinear, least-squares curve-fitting computer software to fit spectrum S sub 1 to this mathematical expression yielded the surface temperature. This technique also measured the spectral reflectivity and emissivity of the surface. Instrumentation necessary to extend measurement to elevated temperatures and in the presence of reflective interference is discussed.