Search NASA⌕ Search

Engineering topics

Nguyen, Hogan

Publications and source records attributed to Nguyen, Hogan.

Design and validation of a cold load for characterization of cosmic microwave background stage 4 detectors

We present the design and validation of a variable temperature cryogenic blackbody source, hereinafter called a cold load, that will be used to characterize detectors to be deployed by cosmic microwave background stage 4 (CMB-S4), the next-generation ground-based cosmic microwave background (CMB) experiment. Although cold loads have been used for detector characterization by previous CMB experiments, this cold load has three innovative design features: (1) the ability to operate from the 1-K stage of a dilution refrigerator (DR), (2) a He3 gas-gap heat switch to reduce cooling time, and (3) the ability to couple small external optical signals to measure detector optical time constants under low optical loading. The efficacy of this design was validated using a 150-GHz detector array previously deployed by the Spider experiment. Thermal tests showed that the cold load can be heated to temperatures required for characterizing CMB-S4’s detectors without significantly impacting the temperatures of other cryogenic stages when mounted to the DR’s 1-K stage. In addition, optical tests demonstrated that external signals can be coupled to a detector array through the cold load without imparting a significant optical load on the detectors, which will enable measurements of the CMB-S4 detectors’ optical time constants.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and validation of a cold load for characterization of CMB-S4 detectors

We present the design and validation of a variable temperature cryogenic blackbody source, hereinafter called a cold load, that will be used to characterize detectors to be deployed by CMB-S4, the next-generation ground-based cosmic microwave background (CMB) experiment. Although cold loads have been used for detector characterization by previous CMB experiments, this cold load has three novel design features: (1) the ability to operate from the 1 K stage of a dilution refrigerator (DR), (2) a 3He gas-gap heat switch to reduce cooling time, and (3) the ability to couple small external optical signals to measure detector optical time constants under low optical loading. The efficacy of this design was validated using a 150 GHz detector array previously deployed by the Spider experiment. Here, thermal tests showed that the cold load can be heated to temperatures required for characterizing CMB-S4’s detectors without significantly impacting the temperatures of other cryogenic stages when mounted to the DR’s 1 K stage. Additionally, optical tests demonstrated that external signals can be coupled to a detector array through the cold load without imparting a significant optical load on the detectors, which will enable measurements of the CMB-S4 detectors’ optical time constants.

47 OTHER INSTRUMENTATION↗

Performance and characterization of the SPT-3G digital frequency-domain multiplexed readout system using an improved noise and crosstalk model

The third-generation South Pole Telescope camera (SPT-3G) improves upon its predecessor (SPTpol) by an order of magnitude increase in detectors on the focal plane. The technology used to read out and control these detectors, digital frequency-domain multiplexing (DfMUX), is conceptually the same as used for SPTpol, but extended to accommodate more detectors. A nearly 5× expansion in the readout operating bandwidth has enabled the use of this large focal plane, and SPT-3G performance meets the forecasting targets relevant to its science objectives. However, the electrical dynamics of the higher-bandwidth readout differ from predictions based on models of the SPTpol system due to the higher frequencies used and parasitic impedances associated with new cryogenic electronic architecture. To address this, we present an updated derivation for electrical crosstalk in higher-bandwidth DfMUX systems and identify two previously uncharacterized contributions to readout noise, which become dominant at high bias frequency. The updated crosstalk and noise models successfully describe the measured crosstalk and readout noise performance of SPT-3G. These results also suggest specific changes to warm electronics component values, wire-harness properties, and SQUID parameters, to improve the readout system for future experiments using DfMUX, such as the LiteBIRD space telescope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Method to Reduce the Coherent Betatron Oscillations in a Muon g-2 Storage Ring Experiment using RF Fields

The muon $g-2$ storage-ring experiments store a beam of polarized muons in a weak focusing storage ring. As the ensemble of muons goes around the ring, their spin precesses, and when they decay through the weak interaction: $\mu^+ \rightarrow e^+ \nu_e \bar{\nu_\mu}$ the decay positrons are detected by electromagnetic calorimeters. In addition to the expected exponential decay in the positron time spectrum, the weak decay asymmetry causes a modulation in the number of positrons at the difference frequency between the spin and cyclotron frequencies, $\omega_a$. This frequency is directly proportional to the magnetic anomaly $a =(g-2)/2$, where $g$ is the gyromagnetic ratio of the muon, which is slightly greater than 2. The detector acceptance depends on the radial position of the muon decay, so the coherent betatron oscillations (CBO) of the muon bunch following injection into the storage ring amplitude modulates the measured muon signal with the frequency $\omega_{CBO}$. A new method using radio frequency (RF) electric fields has the potential to significantly decrease the beam CBO, and additionally to scrape the beam to reduce muon losses from the storage ring during the measurement period.

43 PARTICLE ACCELERATORS↗

Commissioning the Superconducting Magnetic Inflector System for the Muon g-2 Experiment

The Fermilab muon g-2 experiment aims to measure the muon anomalous magnetic moment with a precision of 140 ppb - a fourfold improvement over the 540 ppb precision obtained in the BNL muon g-2 experiment. Both of these high-precision experiments require an extremely uniform magnetic field in the muon storage ring. A superconducting magnetic inflector system is used to inject beam into the storage ring as close as possible to the design orbit while minimizing disturbances to the storage-region magnetic field. The Fermilab experiment is currently in its first data-taking run, where the Fermilab inflector system is the refurbished BNL inflector system. This discussion reviews the Fermilab inflector system refurbishment and commissioning.

43 PARTICLE ACCELERATORS↗

Commissioning the Muon g-2 Experiment Electrostatic Quadrupole System

The Fermilab Muon g-2 experiment aims to measure the muon anomaly with a precision of 140 parts-per-billion (ppb) - a fourfold improvement over the 540 ppb precision obtained by the BNL Muon g-2 experiment. These high precision experiments both require a very uniform muon storage ring magnetic field that precludes the use of vertical-focusing magnetic quadrupoles. The Fermilab Electrostatic Quadrupole System (EQS) is the refurbished and upgraded BNL EQS, where this overview describes the Fermilab EQS and its recent operations.

43 PARTICLE ACCELERATORS↗

Quantum Sensing for High Energy Physics

Report of the first workshop to identify approaches and techniques in the domain of quantum sensing that can be utilized by future High Energy Physics applications to further the scientific goals of High Energy Physics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗