Search NASA⌕ Search

Engineering topics

Niazy, N.

Publications and source records attributed to Niazy, N..

Effects of solution mass transport on the ECC ozonesonde background current

A technique is developed to measure the effective mass transport parameter for the electrochemical concentration cell (ECC) ozonesonde in order to determine the mass transport rate constant for the ECC as a function of pressure. It is shown that a pressure dependent factor in the background current originates in a convective mass transport parameter. It is determined that for atmospheric pressures greater than 100 mb the mass transport parameter is a constant, while at pressures less than 100 mb it decreases logarithmically with pressure. It is suggested that the background current correction is directly correlated to the mass transport parameter pressure dependence. The presently used background current correction, which is based on the partial pressure of oxygen, is found to lead to an overestimation of the integrated ozone value in the troposphere for the ECC ozonesonde data.

Thornton, D. C.↗

Effects of solution mass transport on the ECC ozonesonde background current

Measurement of the mass transport rate constant for the electrochemical concentration cell in an ozonesonde as a function of the pressure is reported. The investigation was performed to accurately model the residual current present in the ECC cell in the absence of ozone. The convective mass transport for two sondes were determined while maintaining a sufficiently negative cathodic potential to eliminate electron transfer at the cathode surface. A sonde was placed in a bell jar and subjected to varying pressure levels. When the background current was kept below 0.1 microamp and pressure was from 100-1000 mb, the necessary correction term for the pressure was independent of pressure. However, below 100 mb, a logarithmic decrease in the background current with pressure is expected. Present practices, involving a sensitivity to oxygen, are calculated to result in overestimation of the total ozone between 1000-10 mb by 0.0096 atm-cm with a background current of 0.1 microamp at 1000 mb.

Thornton, D. C.↗

Sources of background current in the ECC ozonesonde - Implications for total ozone measurements

The source of the background current in the usual operation of the electrochemical concentration cell ozonesonde is the reduction of tri-iodide normally present in the cathode solution. The time variations in the background current can be explained by the slow rates of solution mass transport and of heterogeneous electron transfer for tri-iodide. Oxygen does not contribute to the background current through reaction with iodide to produce tri-iodide. Direct reduction of oxygen at the cathode is negligible once the electrodes have been exposed to iodide for 24 hours. The present background current correction is altitude-dependent, since it is based on an assumed sensitivity of the electrochemical concentration cell to oxygen. If the background current is independent of altitude and of oxygen, a constant, uncorrected, background current of 0.1 microamp would produce an error of +5.5% for the total ozone value of the electrochemical concentration cell for a typical midlatitude total ozone value of 0.345 atm-cm.

Thornton, D. C.↗