Search NASASearch

Engineering topics

Nicholas F Materer

Publications and source records attributed to Nicholas F Materer.

Recirculating and Sub-Atmospheric Rapid Cycle Amine Swing Bed Testing at Various Metabolic Profiles, Temperatures, and Half-Cycle Times

Sixty years since the first spacewalk, NASA’s Extravehicular Mobility Unit (xEMU) exploration space suit has undergone numerous design improvements and iterations. As commercial manufacturers develop next-generation systems to support increasingly complex missions, including Moon-to-Mars architecture prototyping and the design of the Martian Portable Life Support System (PLSS), material selection and individual subunit testing under realistic metabolic and pressure conditions are paramount. To determine whether a reusable carbon dioxide (CO 2 ) scrubber design and adsorbent can be utilized in new suit configurations, an all-encompassing test rig is required to compare existing and newly developed technologies. The test rig must be capable of sub-atmospheric testing, calibrated humid CO 2 dosing, and facilitation of the evaluation of sorbents across a wide range of operational requirements. Recently, XploSafe has developed an Extravehicular Mobility Unit (xEMU) testing rig specifically designed to explore CO 2 and humidity control materials for spacesuits. This closed-loop recirculating swing bed (Rapid Cycle Amine Test Rig) was utilized to compare adsorbent utility across a wide range of xEMU operating conditions. Following successful testing with Xplo-SA9T over multiple simulated eight-hour Extravehicular Activity (EVA) tests, improvements to the test stand were considered. Regeneration vacuum supply within the test rig was updated to more closely resemble space vacuum, theoretically increasing half-cycle timing. An improved water vapor delivery system was incorporated to dose a wider calibrated range of humidity over both short and long-duration EVAs. A range of metabolic profiles between 800 and 3000 BTU/h were tested, and the corresponding average CO 2 steady-states were compared. The effect of dosing temperature at the adsorbent bed inlet between 10 and 40 ̊C and the corresponding CO 2 removal efficiency was also evaluated.

John R Tidwell

Dynamic Regulation of Sub-Atmospheric Pressure for Constant and Cyclic Gas Loads During Testing of Spacesuit Components

New iterations of the various subsystems within the spacesuit will benefit from a new sorbent technology. For example, sorbents used in the Trace Contaminant Control (TCC) and the Rapid Cycle Amine (RCA) systems within the Exploration Portable Life Support System (xPLSS), part of the Extra-Vehicular Mobility Unit (xEMU). For proper validation, the sub-atmospheric pressure needs to be maintained within a simulated 2 ft 3 spacesuit volume. The traditional approach, which involves placing the entire vent loop within a hypobaric chamber, is not practical for the widespread testing of components and prototypes, as these specialized chambers are costly and not widely available. A two-stage regulator based sub-atmospheric pressure system is presented in this work. The method regulates the pressure based on pressure differentials between the pressure regulation pump, the test system, and the ambient environment. The performance of this system is demonstrated using data collected during a 150+ hour non-regenerative TCC sorbent evaluation, several 24-hour regenerative TCC sorbent evaluations with different regeneration cycles, and an 8-hour RCA sorbent evaluation, all under xEMU operating conditions. For regulation, the inlet regulator was set to propagate a small leak to increase the stability of the system as the gas load from the testing system changes. It was also found that controlling the input flow rate that replaces the material lost during regeneration is critical for ensuring the stability of the system. This system provided excellent pressure regulation, without adjustments, for constant loads during shorter time evaluations (hours), while longer time evaluations (days) are easily obtainable with periodic regulator adjustments. A second method is under development to address longer-term stability and to automate pressure regulation. It will incorporate flow and pressure measurements to dynamically control a set of electronically controlled proportional valves for adjusting the pumping speed and air bleed supply.

Nicholas F Materer

Evaluation of Long-Term Storage Stability and Operational Efficiency of Rapid Cycle Amine Adsorbents

With the recent incorporation of Mars Extravehicular Activity (EVA) into the 2025 NASA roadmap, Rapid Cycle Amine (RCA) technology advancement within the Exploration Extravehicular Mobility Unit (xEMU) applies to both the upcoming Lunar Artemis missions and future human exploration of Mars. The incorporation of commercial spacesuit vendors to service NASA’s crewed-space programs since 2021 has increased the demand for regenerable, RCA-based carbon dioxide (CO2) and humidity control adsorbents. The regenerable RCA subunit is the most advanced, long-term solution for CO2 removal and humidity control, enabling both lunar and Martian EVAs. The adsorbent selected for use within the RCA unit must exhibit sufficient storage stability and operational efficiency for prolonged missions. As XploSafe worked to simultaneously develop both a recirculating sub-atmospheric test rig and adsorbents for the RCA system within the xEMU, several novel adsorbents were evaluated for long-term storage stability in support of future extended-duration missions. The chosen materials were periodically evaluated by nuclear magnetic resonance (NMR) spectroscopy, thermal desorption-coupled with gas chromatography/mass spectrometry (TD-GC/MS), and CO2 adsorption to assess long-term storage efficacy across various environmental storage conditions. NMR spectroscopy was utilized by extracting the active CO2 adsorbing chemical from the solid support with deuterated solvent and comparing the spectra over time for degradation and change. The solid adsorbents were also analyzed via TD-GC/MS to reveal any potential off-gassing chemicals over time. Additionally, XploSafe’s breakthrough test rig was utilized to dose the solid adsorbents with a 585 BTU/h metabolic rate flow-equivalent CO2 stream and monitored for 0–99% CO2 breakthrough. The performance metrics from the breakthrough analysis were compared over the storage study duration for CO2 removal and humidity control. Xplo-SA9T was evaluated for 24 months, whereas two additional adsorbent variants, MMPA-Sorbent and LPEI-Sorbent, were each evaluated for 12 months.

John R Tidwell