Baseline Hypothetical Facility for the Production of 131 I, 99 Mo, and 133 Xe from HALEU Fission Targets

The report describes the development of a hypothetical facility to produce the pharmaceutical radioisotope 131 I at an amount of 60 curies per week via the fission of a High Assay Low Enriched Uranium (HALEU) target, along with the chemical and physical processes and equipment needed to separate the 131 I and co-produced 99 Mo and 133 Xe. The hypothetical design was carried out using a 10 MWt research reactor. The irradiation calculation determined that three HALEU targets with aluminum cladding can be used to produce 60 Ci/week of 131 I, 750 Ci/week of 99 Mo and 560 Ci/week of 133 Xe. The process selected for the baseline design uses caustic dissolution of the target material with ion exchange processes to separate and purify the iodine and molybdenum. The xenon is processed using a cryogenic carbon bed separation process. Target processing occurs in seven shielded hot cells with a total footprint of 16m 2 and waste management occurs in an eight hot cell with a 2.5 m 2 footprint. Waste generated from the processing of the three targets per week would generate less than 4 shielded drums of waste annually. These hot cells would need varying levels of shielding due to the amount of fission products being handled in the unit. Hot cell facilities also require support services including QA/QC, health physics, administrative staff, operator changing room, radiological buffer areas, and waste storage. The overall facility would require a footprint of 1050 m 2 with 20.25 m 2 of shielded hot cells.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiological Handling and Containment Considerations in Support of an American Medical Isotope Producer

This work will discuss evaluation and design of new and modified facility level radiological containment, transfer, and handling systems in support of the United States’ American Medical Isotope Production Act. In the United States alone, Molybdenum-99 (Mo-99) is used as a precursor to locally generate its decay product, technetium-99m (Tc-99m), for use in approximately 40,000 medical procedures every day to detect cancer and heart disease. Currently, however, Mo-99 is primarily produced overseas and typically requires highly enriched uranium (HEU) which is classified as weapon -usable. This poses a serious security risk to the United States and, in 2012, Congress passed the American Medical Isotope ACT which aimed to cease all Mo-99 production that requires HEU and support American based companies who have found safer production methods. Through this effort, a system was designed and developed to access irradiated material in processing hot cells for ease of material introduction and removal in the confined area. The proposed solution uses a double-door design that allows for easy access to material while also providing shielding through a mechanically manipulated carousel. A system was also designed to transport irradiated materials from target reactors to a target receipt box using a rail guide system, pneumatic motor, and lead screw drive.

07 ISOTOPE AND RADIATION SOURCES↗

Characterizing The Mechanical Properties of Polyurethane Foams

The Department of Energy has many radioactive facilities that are on the path of deactivation and decommissioning (D and D). These facilities can sit cold and dark for many years before final disposition, and must be maintained to ensure no radiological release occurs in the interim. Improvements and additions to D and D tool sets can greatly: Save time and money, Reduce worker risk. Conventional fixatives widely used often take the form of paints or films that are not readily applicable to 3-dimensional void spaces. Foams are one promising platform that may offer solutions to a number of contaminated problem sets such as: Gloveboxes, Pipes, Tanks. SRNL is working to characterize various commercial foams that would encapsulate the interior volume of a given space and are capable of immobilizing any remaining contamination. One key performance metric of these foams is how well they will perform in an accident scenario. To this end, SRNL is researching the mechanical properties of these foams to ensure that the material can withstand the environment of application while maintaining structural integrity. ASTM standard E3191-18 served as a guiding document for this project, outlining the requirements that foaming fixatives used for the mitigation of radioactive contamination need to meet before being implemented. Objective: Quantification of the mechanical properties of 6 commercial polyurethane foams was performed using multiple ASTM standards to record measurements for: Compression testing: Flexible Foams, Force required to produce 50% compression, Rigid Foams, Compressive and apparent modulus, Point of 10% core deformation, The 'Zero Deformation' point, Compressive strength, Yield point. Tensile testing: Tensile strength, Tensile stress, Percent elongation. Experiment 1: An electromechanical compressive tester (MTS Criterion Series 43) was used to evaluate 6 foams (4 flexible, 2 rigid). Per ASTM D1621, each rigid foam was compressed at 10% of the measured thickness per minute until the sample was 13% of it's original thickness. Per ASTM D35/4, each flexible foam was pre-flexed twice to 80% original thickness at a rate of 250 mm/min, then compressed to 80% original thickness at a rate of 50 mm/min. Experiment 2: An electromechanical tensile tester (MTS Criterion Series 43) was used to evaluate 6 foams (4 flexible, 2 rigid). Per ASTM D1623, rigid foams were pulled apart at a rate of 1.27 mm/min until the sample broke. Per ASTM D35/4, flexible foams were pulled apart at a rate of 500 mm/min until the sample broke. The strongest material in both compression and tensile testing scenarios was found to be the rigid intumescent polyurethane Hilti foam. The experiments revealed that the Hilti foam in a tensile scenario had a peak stress value that was larger than the closest competitor by a factor of 2.3 and a compressive yield point that was larger than the closest competitor by a factor of 1.4, indicating that the Hilti foam is the best choice for implementation in mechanically harsh environments. The performance metrics measured can serve as a basis for future mechanical tests that would help set relevant ASTM standards (E3191) for intumescent polyurethane foams in fixating applications. Tests like surface adhesion, impact, and flame tests would serve as a better indicator as to how this material would perform in environmentally harsh scenarios often found in decommissioned nuclear facilities. Further tests of the foams' intumescent properties would also be important should these foams be implemented in environmentally harsh scenarios.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Adhesion Capabilities of Permanent Foaming Fixatives

DOE-EM have identified an operational requirement for a fixative that can immobilize and/or encapsulate residual contamination in 3D void volumes (pipes, gloveboxes, waste containers, etc.) during D and D activities. Failure to safely and effectively immobilize residual contamination can: Put workers at risk; Contaminate the public and environment; Drive up costs. Commercial-off-the-shelf (COTS) polyurethane (PU) foams is one possible solution and is currently being investigated by Savannah River National Lab (SRNL). Adhesion testing will dictate how well PU foams will adhere and immobilize residual contamination onto a substrate. Results can provide a performance criteria for Section 5 of ASTM E3191: Standard Specification for Permanent Foaming Fixatives Used to Mitigate Spread of Radioactive Contamination. Initial mechanical testing showed intumescent rigid PU foams were best in class (tensile, compression, TGA/DSC) Application of intumescent rigid PU foam in pipe scenario with 'contamination' showed excellent adhesion capabilities as long as foam had contact with pipe. The foam, however, was not able to penetrate 'contamination' but created pockets where the contamination interacted with the substrate. Pretreatment options of pipe were considered to produce better immobilization capabilities. Pretreatment options included COTS products like baking spray, rubber cement, and soap. Foam was still able to immobilize on a global sense, but not a local sense. Essentially acted as a mechanical plug. A tensile tester (MTS Criterion Series 43) was utilized to evaluate the tensile adhesion strength of 6 COTS PU foams. ASTM D1623: Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics. Procedures: PU foams were cured between two smooth 2'' x 2'' 304 stainless steel coupons with hinges glued on plates for gripping support. Parameters Used: Pull rate of 0.1 in/min. Calculations: Tensile adhesion strength, elongation, and ImageJ analysis of how PU foam is left on substrate. Outcome: The PU foam with the best adhesion capabilities would be downselected for further evaluation to be used as a permanent foaming fixative. The rigid PU foams had the best adhesion capabilities with the R1 foam having a max load of 236 N. One of the I-R2 samples reached almost 450 N and another sample reached 2500 N before slipping. The other intumescent foam, I-F4, had the most coverage on the stainless steel coupon's surface from the ImageJ results (61.43% surface coverage). The intumescent foam, I-R2, will be the foam of choice for future testing due its fire retardant and adhesion capabilities. Future directions: Conduct the following experiment in a pipe scenario with the down-selected PU foam. Procedures: PU foam will be cured between in a 304 stainless steel pipe (ID: 4'', OD: 4.5'', Height: 4''). Parameters Used: Compression testing results will be referenced to determine if foam's adhesion strength would be greater its compression strength as its being compressed. Calculations: Compression strength, shear stress, total time elapsed. Conduct further adhesion testing with the down-selected PU foam (I-R2) to be treated as a permanent foaming fixative (PFF). Determine the minimum contact the PFF should have with the substrate for adequate results. Evaluate if PFF's adhesion capabilities is time dependent (3.1.5 of ASTM E3911). Subject PFF to seismic stressors addressed in Safety Basis of Interim Operation documents (SBIO) to further evaluate adhesion capabilities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗