Galileo probe forebody thermal protection - Benchmark heating environment calculations

Solutions are presented for the aerothermal heating environment for the forebody heatshield of candidate Galileo probe. Entry into both the nominal and cool-heavy model atmospheres were considered. Solutions were obtained for the candidate heavy probe with a weight of 310 kg and a lighter probe with a weight of 290 kg. In the flowfield analysis, a finite difference procedure was employed to obtain benchmark predictions of pressure, radiative and convective heating rates, and the steady-state wall blowing rates. Calculated heating rates for entry into the cool-heavy model atmosphere were about 60 percent higher than those predicted for the entry into the nominal atmosphere. The total mass lost for entry into the cool-heavy model atmosphere was about 146 kg and the mass lost for entry into the nominal model atmosphere was about 101 kg.

Balakrishnan, A.↗

Galileo probe forebody entry thermal protection - Aerothermal environments and heat shielding requirements

Solutions are presented for the aerothermal heating environments and the material thermal response for the forebody heatshield on the candidate 242 kg Galileo probe entering the modeled nominal and cold-dense Jovian atmospheres. In the flowfield analysis, a finite difference procedure was employed to obtain benchmark predictions of pressure, radiation and convective heating rates (both laminar and turbulent) and the corresponding wall blowing obtained under the steady state approximation. The fluxes over the probe flank were found to be in a range where spallation is an important mass loss mechanism. The predicted heating rates were also used as boundary conditions for a charring materials ablation which was used to predict thermochemical based surface recession, mass loss and bondline temperatures. The contingency factor of 30% currently employed by NASA was found to be insufficient for entry into the cold-dense atmosphere.

Nicolet, W. E.↗

Aerothermodynamic environment for Jovian entry with silica heat shield

Solutions are presented for the stagnation-region shock-layer equations, including radiative transfer with spectral lines and silica ablation during Jovian entry. Results for variations of entry angle, sphere-cone configuration, and atmospheric model are given. The effect of silica ablation on the radiative and convective surface heating is correlated with the ratio of the wall to free-stream mass flux. Correlations are also given for spectral distributions. The effect of newly obtained SiO radiation properties on the surface heating is examined.

Green, M. J.↗

Aerothermodynamic environment for Jovian entry conditions

Solutions are presented for the aerothermal heating environments about blunt probes entering the atmosphere of Jupiter. The analysis employs a novel prediction procedure in which finite differences versions of the thin layer fluid dynamic equations are solved simultaneously with, and coupled to, a fully detailed radiation flux model. Predictions are presented and compared with those of earlier investigators. Radiative blowing corrections are presented for on- and off-stagnation point conditions. The use of a blowing correlation based on the retained mass was found to be useful for off-stagnation point conditions.

Nicolet, W. E.↗

Rapid methods for calculating radiation transport in the entry environment

A procedure is developed for the prediction of radiation transport events in the context of the entry heating environment. The equivalent-width and exponential approximations are employed to reduce the computational requirements of the governing equations. Novel features are introduced in the use of an Elsasser band model to estimate line overlapping events and in the formulation of the wall reflection events. A matrix of calculations is presented to allow an assessment of the trade-offs between accuracy and computational efforts. It is concluded that the equivalent width model allows significant savings in computational effort with only modest penalties in accuracy. Consequently, the model should be viewed as an attractive candidate for use in radiation-coupled flow field prediction procedures.

Nicolet, W. E.↗

The aerothermal environment and material response: A review

Aerothermal environments are discussed with emphasis on the cold dense and warm atmospheres of Saturn and Uranus. The spectral distribution of the incident radiation flux is given for the Saturn nominal entry. Saturn and Uranus stagnation point heat pulses with no ablation are compared. Calculations for small flow rates, important in the Saturn-Uranus nominal type entries, are given to investigate the effects due to the mixing layer separation. Analytical and experimental techniques applicable to flowfield calculations are reviewed with emphasis on two--dimensional flow capabilities. Transport properties are reviewed in terms of flowfield calculations along with radiation transport codes. Various approaches to entry calculations are presented. It is indicated that only certain aspects of the aerothermal environment can be simulated in the laboratory and that although flight experiments are becoming feasible they are so expensive that they are prohibitive. Recommendations for further study are included.

Nicolet, W. E.↗

Outer planet probe entry thermal protection. I Aerothermodynamic environment

Solutions are presented for the aerothermal heating environments about blunt probes of various shape entering the candidate atmospheres of Saturn and Uranus. The analysis makes use of a series of interacting codes to predict pressures, cold wall radiative fluxes, cold wall convective fluxes, and corresponding corrections for the radiative and convective fluxes. The solutions show that ablation will either enhance or reduce the radiative flux to the surface depending on the ablation gas composition and ablation rate. Other conclusions suggested by the solutions are discussed.

Nicolet, W. E.↗

Outer planet probe entry thermal protection. II - Heat shielding requirements

Solutions are presented for the material thermal response for heat shields of blunt probes entering Saturn and Uranus. Both monolithic and sandwich concepts were considered having exposed charring ablative or reflective materials. The solutions show that (1) Teflon heat shields are sized by mass loss considerations, other materials (unless entering the Uranus cold-dense atmosphere) by heat soak considerations, (2) steeper entries require less heat shield mass, (3) sizing requirements vary little about the bodies for heat soak dominated materials, and (4) carbon-phenolic appears superior overall, but silica is superior for the steeper entries and the high helium content atmospheres.

Nicolet, W. E.↗

User's manual for RAD/EQUIL/1973: A general purpose radiation transport program

A procedure is described for implementing the RAD/EQUIL/1973 program, and instructions are given which allow the program input to be prepared, the output to be interpreted, the operating procedures identified which must be followed, and the meaning of the error messages to be understood. The structure of the program is described through a verbal description, a FORTRAN variables list, and a listing of the program.

Nicolet, W. E.↗

Heat shielding for Venus entry probes.

Two contrasted approaches to ablative thermal protection of Venus entry probes are presented - a typical carbonaceous charring ablator and a dielectric reflective ablator. The interesting observation in this study is that mass loss is not the controlling variable in heat-shield sizing. A heat-soak problem determines the carbon phenolic sizing. For Teflon, the material thickness required to accomplish reflection is the sizing factor. The total heat-shield weight required to handle either steep or shallow entry is computed to be 13% less for a Teflon shield (if at least 3.2 mm are required for reflection) than for a charring ablator shield. If an efficient reflective backing is used with Teflon, the thickness can be reduced 1.0 mm and the computed weight is 31% less for Teflon than for the charring ablator. Such weight reductions may significantly increase the science payload weight of the miniprobes.

Peterson, D. L.↗