Search NASA⌕ Search

Engineering topics

Niiya, I.

Publications and source records attributed to Niiya, I..

Demonstration of transient CHI startup using a floating biased electrode configuration

Abstract Results from the successful solenoid-free plasma startup using the method of transient coaxial helicity injection (transient CHI) in the QUEST spherical tokamak (ST) are reported. Unlike previous applications of CHI on HIT-II and on NSTX which required two toroidal insulating breaks to the vacuum vessel, QUEST uses a first of its kind, floating single biased electrode configuration, which does not use such a vacuum break. Instead, the CHI electrode is simply insulated from the outer lower divertor plate support structure. This configuration is much more suitable for implementation in a fusion reactor than the previous configurations. Transient CHI generated toroidal currents of 135 kA were obtained. The toroidal current during the formation of a closed flux configuration was over 50 kA. These results bode well for the application of transient CHI in a new generation of compact high-field STs and tokamaks in which the space for the central solenoid is very restricted.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectroscopic measurement of increases in hydrogen molecular rotational temperature with plasma-facing surface temperature and due to collisional-radiative processes in tokamaks

Abstract Spatially resolved rotational temperature of ground state hydrogen molecules desorbed from plasma-facing surface was measured in QUEST, LTX-β, and DIII-D tokamaks, and the increases of the rotational temperature with the surface temperature and due to collisional-radiative processes in the plasmas were evaluated. The increase due to collisional-radiative processes was calculated by solving rate equations considering electron and proton collisional excitation and deexcitation and spontaneous emission. The calculation results suggest a high sensitivity for the rotational temperature to electron and proton densities, but a negligible sensitivity to the electron, proton, and surface temperatures. In the three tokamaks with different plasma parameters and plasma-facing surface materials, the spatial profile of the rotational temperature was estimated using Fulcher-α emission lines (600–608 nm). In QUEST, the spatial profile of the rotational temperature was estimated from spatially resolved spectra. In the other tokamaks, the rotational temperature was evaluated assuming a single point emission with a location determined from the Fulcher-α emission profile as measured with a filtered camera. In metal-walled devices QUEST and LTX-β, the rotational temperature increased with the surface temperature, and the calculated collisional-radiative increase is consistent with measured increase assuming that the rotational temperature at the surface is approximately 500–600 K higher than the surface temperature. In DIII-D with carbon walls, a larger collisional-radiative increase than the other tokamaks was observed because of the higher density leading to a large difference from the calculated increase compared to the other smaller tokamaks. Measurement of the Fulcher-α emission profile with higher spatial resolution in DIII-D may reduce the difference and reveal the effect of the surface temperature on the rotational temperature. These results show the increases in the rotational temperature with the surface temperature and due to the collisional-radiative processes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improvements to the High-Field-Side Transient CHI System on QUEST

Transient coaxial helicity injection (CHI) is a promising candidate for solenoid-free plasma current start-up in a low-aspect-ratio tokamak in support of developing fully non-inductive scenarios. The aim of the transient CHI research on QUEST is to develop a reactor-relevant CHI design. On QUEST, a CHI discharge is initiated by driving current along magnetic field lines that connect an electrically insulated electrode plate (which is referred to as a bias electrode) to a vessel component at the bottom region of the spherical tokamak. In the first application of CHI on QUEST, the electrically insulated electrode plate was biased with respect to the outer vessel in a configuration referred to as low-field-side (LFS) injection. To maintain a narrow injector flux footprint width throughout the discharge, QUEST is now developing a high-field-side (HFS) injection configuration, in which the electrically insulated electrode plate is biased with respect to the inner vessel components. Through the implementation of a CHI-dedicated gas injection system, studies in the HFS injection configuration have now demonstrated good magnetic flux evolution into the vacuum vessel. Toroidal currents up to 43 kA have been achieved, and the generated current has increased in proportion to the magnetic flux connecting the electrodes. Finally, these results which show agreement with the CHI-scaling suggest that much higher levels of toroidal current can be generated on QUEST in an optimized CHI system in which the magnetic flux connecting the CHI electrodes is further increased.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗