Search NASA⌕ Search

Engineering topics

Nikolic, Heather

Publications and source records attributed to Nikolic, Heather.

26 records · Page 2

Large Pilot CAER Heat Integrated Post-combustion CO 2 Capture Technology for Reducing the Cost of Electricity

The goal of this final project report is to comprehensively summarize the work conducted on project DE-FE0026497. In accordance with the Statement of Project Objectives (SOPO), the University of Kentucky Center for Applied Energy Research (UKy-CAER) (Recipient) has developed an advanced, versatile, 10 MWe post-combustion CO 2 capture system (CCS) for a coal-fired power plant, Louisville Gas and Electric Company’s Trimble County Generating Station, using a heat integrated process combined with two-stage stripping and any advanced solvent to enhance the CO 2 absorber performance. The proposed project (Phase 1 and 2) will involve the design, fabrication, installation and testing of a large pilot scale facility that will demonstrate the UKy-CAER innovative carbon capture system integrated with an operating supercritical power plant. Specifically during Phase 1, the Recipient has provided all necessary documentation to support its Phase 2 down-selection including: the Project Narrative, the updated Project Management Plan (PMP), the preliminary engineering design, the Technical and Economic Analysis report (TEA) (including the Case 12 – Major Equipment List and submitted as a Topical Report), a Phase 1 Technology Gap Analysis (TGA), an Environmental Health and Safety (EH&S) Assessment on the 10 MWe unit, and updated Phase 2 cost estimates (including the detailed design, procurement, construction, operation, and decommissioning costs) with a budget justification. Furthermore, the Recipient has proposed a combined modular and freestanding column configuration with an advanced absorber gas/liquid distribution system, an advanced solvent, with the integration of discrete packing, a smart cross-over heat exchanger, and a load and ambient condition following control strategy, all to address ten of 12 technology gaps identified during the Phase I work. If successful, the proposed heat integrated post-combustion CCS will pave the way to achieve the United States Department of Energy National Energy Technology Laboratory (U.S. DOE NETL) CO 2 capture performance and cost target, as indicated in the submitted TEA and summarized in this report.

01 COAL, LIGNITE, AND PEAT↗

Techno-Economic Analysis of a Secondary Air Stripper Process

We present results of an initial techno-economic assessment on a post-combustion CO2 capture process developed by the Center for Applied Energy Research (CAER) at the University of Kentucky using Mitsubishi Hitachi Power Systems’ H3-1 aqueous amine solvent. The analysis is based on data collected at a 0.7 MWe pilot unit combined with laboratory data and process simulations. The process adds a secondary air stripper to a conventional solvent process, which increases the cyclic loading of the solvent in two ways. First, air strips additional CO2 from the solvent downstream of the conventional steam-heated thermal stripper. This extra stripping of CO2 reduces the lean loading entering the absorber. Second, the CO2-enriched air is then sent to the boiler for use as secondary air. This recycling of CO2 results in a higher concentration of CO2 in the flue gas sent to the absorber, and hence a higher rich loading of the solvent exiting the absorber. A process model was incorporated into a full-scale supercritical pulverized coal power plant model to determine the plant performance and heat and mass balances. The performance and heat and mass balance data were used to size equipment and develop cost estimates for capital and operating costs. Lifecycle costs were considered through a levelized cost of electricity (LCOE) assessment based on the capital cost estimate and modeled performance. The results of the simulations show that the CAER process yields a regeneration energy of 3.12 GJ/t CO2, a $53.05/t CO2 capture cost, and LCOE of $174.59/MWh. This compares to the U.S. Department of Energy’s projected costs (Case 10) of regeneration energy of 3.58 GJ/t CO2 , a $61.31/t CO2 capture cost, and LCOE of $189.59/MWh. For H3-1, the CAER process results in a regeneration energy of 2.62 GJ/tCO2 with a stripper pressure of 5.2 bar, a capture cost of $46.93/t CO2, and an LCOE of $164.33/MWh.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Pilot testing of a heat integrated 0.7 MWe CO 2 capture system with two-stage air-stripping: Emission

The University of Kentucky Center for Applied Energy Research (UKy-CAER) designed, constructed and tested an advanced 0.7 MWe post-combustion CO 2 capture system on a coal-fired power plant using a heat integration process combined with two-stage stripping to enhance the CO 2 absorber performance and lower the cost of CO 2 capture. Evaluation of emissions from the solvent and degradation products was performed to determine the impact on the amine solvent of coal combustion flue gas contaminants and oxygen exposure due to incorporation of the secondary air stripper into the conventional amine absorber/stripper system. The overall amine, ammonia and aldehyde emission levels observed during the baseline 30% monoethanolamine (MEA) solvent testing campaign were generally comparable to previously published reports tested at similar flue gas conditions and system operating hours. Ammonia emissions were correlated to high levels of iron and copper in the solvent, likely as a result of material corrosion.

20 FOSSIL-FUELED POWER PLANTS↗

Pilot testing of a heat integrated 0.7 MWe CO 2 capture system with two-stage air-stripping: Amine degradation and metal accumulation

An advanced 0.7 MWe small pilot coal-fired post-combustion CO 2 capture system with heat integration combined with two-stage stripping was tested here on a slipstream of flue gas by the University of Kentucky Center for Applied Energy Research (UKy-CAER). Evaluation of solvent degradation products was performed to determine the impact of oxygen exposure due to incorporation of the secondary air stripper into the conventional amine absorber/stripper system. The overall degradation rates and products observed during the testing campaign were comparable to previously published reports using 30% monoethanolamine (MEA) as the baseline/commissioning solvent. The rates of heat stable salt accumulation and amine degradation were similar to those from conventional CO 2 capture systems using MEA. Metal accumulation as the result of material corrosion inside the system from an improperly constructed material was observed. Finally, the impact of the secondary air stripper appears negligible relative to other published MEA campaigns tested at similar flue gas conditions and system operating hours.

03 NATURAL GAS↗

Solvent Degradation and Emissions from a 0.7MWe Pilot CO 2 Capture System with Two-stage Stripping

The UKy-CAER team successfully tested an advanced 0.7 MWe post-combustion CO 2 capture system on a coal-fired power plant using a heat integration process combined with two-stage stripping to enhance the CO 2 absorber performance. One of the unique feature of the UKy-CAER integrated process is a two-stage stripping unit for solvent regeneration. The secondary stripper is empowered by the heat rejection from a conventional steam-heated (primary) stripper. The secondary stripper outlet stream at the commercial scale can be used as boiler secondary combustion air, consequently enriching the flue gas with CO 2 , resulting in less energy penalty required by the CO2 capture system. The primary goal of this study was to form an initial assessment of the impact on the amine solvent from coal combustion flue gas contaminants and the potential higher oxygen content in the solvent due to incorporation of the secondary air stripper into the conventional amine scrubber/stripper system. The overall oxidative degradation was comparable to previous reports with 30 wt% MEA solvent at similar flue gas run hours. This suggests that the addition of the secondary air stripper appears to be negligible with regards to solvent oxidation.

20 FOSSIL-FUELED POWER PLANTS↗

Use of Carbon Steel for Construction of Post-combustion CO 2 Capture Facilities: A Pilot-Scale Corrosion Study

Corrosion studies were carried out on metal coated and noncoated carbon steel as well as stainless steel in a pilot-scale post-combustion CO 2 capture process. Aqueous 30 wt % monoethanolamine (MEA) solvent was used without any chemical additive for antioxidation to examine a worst-case scenario where corrosion is not mitigated. The corrosion rate of all carbon steels was almost zero in the absorber column and CO 2 lean amine piping except for Ni-coated carbon steel (<1.8 mm/yr). Ni 2 Al 3 /Al 2 O 3 precoated carbon steels showed initial protection but lost their integrity in the stripping column and CO 2 rich amine piping, and severe corrosion was eventually observed for all carbon steels at these two locations. Stainless steel was found to be stable and corrosion resistant in all of the sampling locations throughout the experiment. This study provides an initial framework for the use of carbon steel as a potential construction material for process units with relatively mild operating conditions (temperature less than 80 °C), such as the absorber and CO 2 lean amine piping of a post-combustion CO 2 capture process. As a result, it also warrants further investigation of using carbon steel with more effective corrosion mitigation strategies for process units where harsh environments are expected (such as temperatures greater than 100 °C).

36 MATERIALS SCIENCE↗