Search NASA⌕ Search

Engineering topics

Nishimura, K

Publications and source records attributed to Nishimura, K.

A Detailed Study of FDIRC Prototype with Waveform Digitizing Electronics in Cosmic Ray Telescope Using 3D Tracks

We present a detailed study of a novel Cherenkov imaging detector called the Focusing DIRC (FDIRC) with waveform digitizing electronics. In this test study, the FDIRC prototype has been instrumented with seven Hamamatsu H-8500 MaPMTs. Waveforms from {approx}450 pixels are digitized with waveform sampling electronics based on the BLAB2 ASIC, operating at a sampling speed of {approx}2.5 GSa/s. The FDIRC prototype was tested in a large cosmic ray telescope (CRT) providing 3D muon tracks with {approx}1.5 mrad angular resolution and muon energy of E{sub muon} > 1.6 GeV. In this study we provide a detailed analysis of the tails in the Cherenkov angle distribution as a function of various variables, compare experimental results with simulation, and identify the major contributions to the tails. We demonstrate that to see the full impact of these tails on the Cherenkov angle resolution, it is crucial to use 3D tracks, and have a full understanding of the role of ambiguities. These issues could not be fully explored in previous FDIRC studies where the beam was perpendicular to the quartz radiator bars. This work is relevant for the final FDIRC prototype of the PID detector at SuperB, which will be tested this year in the CRT setup.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Focusing DIRC with Waveform Digitizing Electronics

We have tested a novel Cherenkov imaging detector called the Focusing DIRC (FDIRC) with waveform digitizing electronics. The prototype's concept is based on the BaBar DIRC with several important improvements: (a) much faster, pixelated photon detectors, (b) a mirror that makes the photon detector smaller and less sensitive to background in future applications, and (c) electronics capable of measuring single photon resolution to {sigma} {approx} 150 ps, which allows for correction due to chromatic error. In this test, the prototype has been instrumented with seven Hamamatsu H-8500 MaPMTs. Waveforms from {approx}450 pixels are digitized with waveform sampling electronics based on the BLAB2 ASIC, operating at a sampling speed of {approx}2.5 GSa/s. This version of the FDIRC prototype was tested in a large cosmic ray telescope providing muon tracks with {approx}1 mrad angular resolution and a muon momentum cutoff of {ge} 1.6 GeV/c.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First observation of radiative B⁰ → ΦK⁰γ decays and measurements of their time-dependent CP violation

We report the first observation of the radiative decay B⁰→ ΦK⁰γ using a data sample of 772 × 10⁶ BB¯ pairs collected at the (4S) resonance with the Belle detector at the KEKB asymmetric-energy e⁺e⁻ collider. We observe a signal of 37 ± 8 events with a significance of 5.4 standard deviations including systematic uncertainties. The measured branching fraction is B(B⁰→ ΦK⁰γ) = (2.74±0.60±0.32)×10⁻⁶, where the uncertainties are statistical and systematic, respectively. We also report the first measurements of time-dependent CP-violation parameters: S ΦK⁰ S γ = +0.74 ⁺0.72 –1.05 (stat) +0.10 –0.24 (syst) and A ΦK⁰ S γ = +0.35 ± 0.58(stat) +0.23 –0.10 (syst). Furthermore, we measure B(B⁺ → ΦK⁺γ) = (2.48 ± 0.30 ± 0.24) × 10⁻⁶, ACP = –0.03 ± 0.11 ± 0.08 and find that the signal is concentrated in the M ΦK mass region near threshold.

Sahoo, Himansu B.↗

High Resolution Photon Timing with MCP-PMTs: A Comparison of a Commercial Constant Fraction Discriminator (CFD) with the ASIC-based Waveform Digitizers TARGET and WaveCatcher

There is a considerable interest to develop new time-of-flight detectors using, for example, micro-channel-plate photodetectors (MCP-PMTs). The question we pose in this paper is if new waveform digitizer ASICs, such as the WaveCatcher and TARGET, operating with a sampling rate of 2-3 GSa/s can compete with 1GHz BW CFD/TDC/ADC electronics. We have performed a series of measurements with these waveform digitizers coupled to MCP-PMTs operating at low gain and with a signal equivalent to {approx}40 photoelectrons. The tests were done with a laser diode on detectors operating under the same condition used previously in SLAC and Fermilab beam tests. Our test results indicate that one can achieve similar resolution with both methods. Although the commercial CFD-based electronics does exist and performs very well, it is difficult to implement on a very large scale, and therefore the custom electronics is needed. In addition, the analog delay line requirement makes it very difficult to incorporate CFD discriminators in ASIC designs.

43 PARTICLE ACCELERATORS↗

First Measurement of Inclusive B{yields}X{sub s{eta}} Decays

We report a first measurement of inclusive B{yields}X{sub s{eta}} decays, where X{sub s} is a charmless state with unit strangeness. The measurement is based on a pseudoinclusive reconstruction technique and uses a sample of 657x10{sup 6}BB pairs accumulated with the Belle detector at the KEKB e{sup +}e{sup -} collider. For M{sub X{sub s}}<2.6 GeV/c{sup 2}, we measure a branching fraction of [26.1{+-}3.0(stat){sub -2.1}{sup +1.9}(syst){sub -7.1}{sup +4.0}(model)]x10{sup -5} and a direct CP asymmetry of A{sub CP}=-0.13{+-}0.04{sub -0.03}{sup +0.02}. Over half of the signal occurs in the range M{sub X{sub s}}>1.8 GeV/c{sup 2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a Transition Edge Sensor Gamma Ray Microcalorimeter with an Epoxy Coupled Bulk Lead Absorber

Transition edge sensor (TES)-based gamma ray detectors have been developed primarily for use up to energies of {approx}100 keV. However, there are many interesting applications at higher energies. We have started to develop a TES gamma-ray detector to apply to Positron Annihilation Spectroscopy analysis at 511 keV. Our detector is composed of a bulk lead absorber, which is coupled to a thin-film TES using a small amount of epoxy. The response of our first detector showed a very long decay tail of {approx}135 ms. To improve the device response time we have designed a new detector in which the response time is improved by a factor of five.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗