Forced Power Systems Oscillations Due to Cyberattacks: Threats, Detection and Partial Mitigation

Forced oscillations in power systems can be caused by misconfigured controllers at generator stations. They can also be caused by cyberattacks against the exciters or governors. This paper explores the effects of forced oscillations from cyberattacks on generator excitation and governor systems and the effectiveness of a novel control system for a static var compensator in mitigating those oscillations to enhance transmission system resilience. A brief overview of oscillations, especially forced oscillations, within power systems is presented, along with an overview of cyberattacks on power systems. This paper also examines and implements FACTS devices to partially mitigate the forced oscillations created by cyberattacks by reducing the magnitude of the oscillations caused by the attack. The proposed approach is more effective against attacks targeting exciters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Secured fault detection in a power substation

Systems and methods for fault detection and protection in electric power systems that evaluates electromagnetic transients caused by faults. A fault can be detected using sampled data from a first monitored point in the power system. Detection of fault transients and associated characteristics, including transient direction, can also be extracted through evaluation of sample data from other monitored points in the power system. A monitoring device can evaluate whether to trip a switching device in response to the detection of the fault and based on confirmation of an indication of detection of fault transients at the other monitored points of the power system. The determination of whether to trip or activate the switching device can also be based on other factors, including the timing of receipt of an indication of the detection of the fault transients and/or an evaluation of the characteristics of the detected transients.

Cui, Tao↗

AI & Physics-Based Bad Command/Data Detection in Large Power Electronics Systems: Multi-Port Autonomous Reconfigurable Solar Power Plant (MARS)

Detection of bad data from measurement sensors and bad commands from control centers need to be carried out to avoid instabilities within large power electronics systems. Towards the same, in this paper, model and data driven methods are proposed to identify anomalies in measured data and commands received by large power electronics systems. The large power electronics system considered in this paper is a multi-port autonomous reconfigurable solar power plant (MARS), which consists of photovoltaic (PV) and energy storage systems (ESSs) that connect to high-voltage direct current (HVdc) system and transmission ac power grid. The proposed algorithms in the MARS power plant to detect bad data from measurements and bad commands from control centers are evaluated in simulations and hardware-in-the-loop (HIL) tests. Furthermore, it has been observed that the proposed algorithms are able to detect bad measurements and commands in all the use cases evaluated.

14 SOLAR ENERGY↗

Multi-Port Autonomous Reconfigurable Solar Power Plant

As the penetration level of power electronics increases and remote photovoltaic (PV) generation is integrated into the alternating current (ac) grid, the short-circuit ratio (SCR) at the point of interconnection of a hybrid PV–energy storage system (ESS) plant may be low. Additionally, the inertia of the alternating current (ac) grid may be low. The low SCRs and inertias can lead to reliability challenges in the power grid. These operating conditions require additional reinforcements, such as synchronous condensers, static var compensators, static synchronous compensators, and high-voltage direct current (HVdc) links/grids. HVdc links or grids may also provide the additional capability of connecting the plant to asynchronous grids and/or connecting asynchronous grids, among others. This scenario leads to discrete development of solar inverters, energy storage inverters, HVdc converters, and several transformers. Some of the problems associated with this discrete development and inverter-based generation include increased cost, lower reliability, and reduced efficiency associated with duplication of power electronics (PEs); competing controls of several individual discrete inverter-based generators due to the presence of multiple PEs, which leads to derating of the system; and transient stability problems arising from inverter-based generation, such as voltage/frequency events leading inverter shutdowns, voltage instability and control interactions in the formed weak grid, and harmonics caused by resonances of multiple inverters.

14 SOLAR ENERGY↗

Technologies for providing secure emergency power control of high voltage direct current transmission system

Technologies for providing secure emergency power control of a high voltage direct current transmission (HVDC) system include a controller. The controller includes circuitry configured to receive status data indicative of a present physical status of a power system. The circuitry is also configured to obtain an emergency power control command triggered by a remote source. The emergency power control command is to be executed by an HVDC transmission system of the power system. Further, the circuitry is configured to determine, as a function of the status data, whether the emergency power control command is consistent with the present physical status of the power system and block, in response to a determination that the emergency power control command is not consistent with the present physical status of the power system, execution of the emergency power control command by the HVDC transmission system.

Pan, Jiuping↗

Anomaly Detection and Mitigation in FACTS-based Wide-Area Voltage Control Systems using Machine Learning

With the increasing deployment of Flexible AC Transmission System (FACTS) devices in wide-area voltage control systems (WAVCS) for achieving improved voltage stability of bulk power systems, the possibility for cyber attacks on these systems is also increasing. Successful stealthy cyber attacks that are difficult to detect by traditional informational technology (IT)-based cybersecurity solutions or threshold-based bad data detectors can lead to a voltage collapse in power grid. This paper presents the testbed-based attacks implementation and real-time evaluation of machine learning (ML) algorithm for detecting and mitigating stealthy cyber attacks on FACTS-based WAVCS on a hardware-in-the-loop (HIL) testbed. Initially, we discuss the implementation of a fuzzy logic controller (FLC) that controls a Static VAR Compensator (SVC) device deployed in a two-area four-machine Kundur power system for improving transient voltage stability. Later, the ML-based Anomaly Detection and Mitigation (ADM) system is implemented on the cyber-physical HIL testbed to detect and mitigate various stealthy cyber attacks, which are injected in real-time over the wide-area network (WAN). The experimental results show accurate and effective performance of ADM system in detecting and mitigating anomalies while keeping the grid stable and within the system operating limits, as defined by the North America Electric Reliability Corporation (NERC).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Machine Learning-based Cyber-Physical Anomaly Detection in Wide Area Voltage Control Systems

Wide-area voltage control systems (WAVCS) are widely deployed in power grid to improve the voltage stability in transmission system using Flexible AC Transmission System (FACTS) devices. The WAVCS relies on wide-area measurement and control signals for closed-loop control of FACTS devices to improve the transient voltage stability in power grid in real-time. Since the WAVCS utilizes a cyber-layer communication during its normal operation, they are susceptible to cyber attacks from adversaries which can lead to a voltage collapse if the attacks go undetected and unmitigated. This paper proposes a supervised machine learning (ML)-based anomaly detection algorithm for detecting various stealthy cyber attacks in the context of WAVCS cybersecurity. In particular, a fuzzy logic-based wide-area controller, as proposed by the Bonneville Power Administration (BPA), is implemented on the Kundur’s four machine two-area system that is integrated with a static var compensator (SVC) to improve voltage profile on sensitive buses. Later, different types of data integrity attacks, including pulse and ramp attacks, are considered on the wide-area measurement and control signals to analyze the performance of the proposed anomaly detector. Our experimental evaluation shows a promising performance with a high true-positive rate (more than 99%) and low false-negative rate (less than 1%) while exhibiting a small prediction time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Virtual Synchronous Generator Control of Multi-port Autonomous Reconfigurable Solar Plants (MARS)

Multi-port autonomous reconfigurable solar power plant (MARS) is an integrated concept for integration of solar photovoltaic (PV) and energy storage systems (ESS) to transmission alternating current (ac) grid and high-voltage direct current (HVdc) links. The integrated development incorporates advanced control methods to provide enhanced grid ancillary services such as fast frequency responses and dynamic voltage support. In this paper, the virtual synchronous generator (VSG) control algorithm of MARS is discussed. The proposed VSG-based control enables enhanced synthetic inertial response and flexible frequency response characteristics of hybrid PV and ESS power plants in accordance with grid ancillary service requirements. Multi-port power electronics interface allows controlled emergency power support from MARS to local transmission ac grid and remote grid through the HVdc link. The performance of VSG control is validated using a reduced-order model of MARS in Simulink. Methods for estimating grid ancillary service capabilities of MARS are also discussed.

Pan, Jiuping↗

Cyber Resilient Flexible Alternating Current Transmission Systems (XFACTS)

This report summarizes the activities conducted under the DOE-OE funded project DEOE0000897, Cyber Attack Resilient Flexible AC Systems – XFACTS. Hitachi Energy (HE), in collaboration with ABB Inc. (ABB), Bonneville Power Administration (BPA), University of Illinois at Urbana-Champaign (UIUC), Iowa State University (ISU), and University of Idaho (UI) pursued the development of a system of defense for Flexible Alternating current Transmission Systems against cyber-attacks (XFACTS). A FACTS substation enhanced with XFACTS defense mechanisms will be capable of mitigating cyberattacks especially those that seek to control electrical parameters like voltage or current and interrupt the power flow in AC lines. It empowers existing FACTS controllers and associated intelligent electronic devices to detect and mitigate malicious intents to depress system voltages, destabilize power flows, trip AC circuit breakers, corrupt currents, and voltages, even if the malicious commands and the measurements have correct syntax. The XFACTS functions utilize the physics of active power electronic systems, control and protection, electric power engineering principles, and state estimation to bring more in-depth cyber defense closer to the protected FACTS substation devices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Securing against malicious control of circuit breakers in electrical substations

An example method for detecting and mitigating attacks on electric power substations comprises detecting a command to open or close a circuit breaker in the electric power substation. A modified extended substation model for the electric power substation is generated, based on the detected command and based on measurements in substation, where the modified extended substation model is a power flow model for the substation and for one or more directly connected neighboring substations. A power flow analysis is performed, using the modified extended substation model, to generate a predicted voltage for each of a plurality of nodes in the substation and in the one or more directly connected neighboring substations. Each predicted voltage is compared to a corresponding allowable voltage range, and execution of the command is blocked in response to determining that one or more of the voltages is outside the corresponding allowable voltage range.

97 MATHEMATICS AND COMPUTING↗

A Localized Cyber Threat Mitigation Approach For Wide Area Control of FACTS

We propose a localized oscillation amplitude monitoring (OAM) method for the mitigation of cyber threats directed at the wide area control (WAC) system used to coordinate control of Flexible AC Transmission Systems (FACTS) for power oscillation damping (POD) of active power flow on inter-area tie lines. The method involves monitoring the inter-area tie line active power oscillation amplitude over a sliding window. We use system instability - inferred from oscillation amplitudes growing instead of damping - as evidence of an indication of a malfunction in the WAC of FACTS, possibly indicative of a cyber attack. Monitoring the presence of such a growth allows us to determine whether any destabilizing behaviors appear after the WAC system engages to control the POD. If the WAC signal increases the oscillation amplitude over time, thereby diminishing the POD performance, the FACTS falls back to POD using local measurements. The proposed method does not require an expansive system-wide view of the network. We simulate replay, control integrity, and timing attacks for a test system and present results that demonstrate the performance of the OAM method for mitigation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Cyber Threat Mitigation Approach For Wide Area Control of SVCs using Stability Monitoring

We propose a stability monitoring approach for the mitigation of cyber threats directed at the wide area control (WAC) system used for coordinated control of Flexible AC Transmission Systems (FACTS) used for power oscillation damping (POD) of active power flow on inter-area tie lines. The approach involves monitoring the modes of the active power oscillation on an inter-area tie line using the Matrix Pencil (MP) method. We use the stability characteristics of the observed modes as a proxy for the presence of destabilizing cyber threats. We monitor the system modes to determine whether any destabilizing modes appear after the WAC system engages to control the POD. If the WAC signal exacerbates the POD performance, the FACTS falls back to POD using local measurements. The proposed approach does not require an expansive system-wide view of the network. We simulate replay, control integrity, and timing attacks for a test system and present results that demonstrate the performance of the SM approach for mitigation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity of Wide Area Monitoring, Protection and Control Systems for HVDC Applications

The flexibility provided by High Voltage Direct Current (HVDC) systems can be further extended by Wide Area Monitoring, Protection, and Control (WAMAPC) systems. WAMPAC systems enable many HVDC applications and, on the other hand, inevitably introduce cybersecurity concerns that need to be addressed. In this work, a security domain layer and decision framework is reported to detect and mitigate the impact of false data injection (FDI) attacks targeting HVDC stations. Specifically, a rule-based cyber-attack detection method is introduced and implemented on Raspberry Pi and tested on the real-time HVDC simulation facility on the real-time digital simulator (RTDS) platform at ABB U.S. Corporate Research Center.

cybersecurity↗

Secured fault detection in a power substation

Systems and methods for fault detection and protection in electric power systems that evaluates electromagnetic transients caused by faults. A fault can be detected using sampled data from a first monitored point in the power system. Detection of fault transients and associated characteristics, including transient direction, can also be extracted through evaluation of sample data from other monitored points in the power system. A monitoring device can evaluate whether to trip a switching device in response to the detection of the fault and based on confirmation of an indication of detection of fault transients at the other monitored points of the power system. The determination of whether to trip or activate the switching device can also be based on other factors, including the timing of receipt of an indication of the detection of the fault transients and/or an evaluation of the characteristics of the detected transients.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber Attack Resilient HVDC System (CARDS) (Final Scientific/Technical Report)

This report summarizes the activities conducted under the DOE-OE funded project DE-OE0000824, where ABB Inc. (ABB), in collaboration with University of Illinois at Urbana-Champaign (UIUC), Bonneville Power Administration (BPA), Argonne National Laboratories (ANL), and University of Idaho (UI) pursued the development of a system of defense for High Voltage Direct Current transmission systems against cyber-attacks (CARDS). An HVDC substation with CARDS features will be more capable of mitigating cyber-attacks especially those that seek to control or interrupt the power flow in the HVDC line. It empowers existing HVDC intelligent electronic devices to collaborate in identifying and blocking malicious intents to trip HVDC AC circuit breakers, block thyristor valves, misconfigure devices settings, even though the commands and the measurements comply with correct syntax. The CARDS functions utilize the physics of electromagnetic AC and DC systems, electric power engineering principles, and state estimation to bring more in-depth cyber defense closer to the protected HVDC substation devices. With the aim of advancing the state of the art, the team proceeded to develop a demonstrable system against cyber-attacks in an HVDC substation environment, via functional upgrades to existing firmware of commercial off-the-shelf HVDC station devices, and/or embedded hardware, without the need for additional instrumentation nor new instrumentation technologies. It is to ensure that the solutions resulting from the project will support the HVDC devices currently installed in the US electricity delivery infrastructure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Secured control of circuit breakers in a digital substation

Methods and systems for secured control of circuit breakers in an electric power substation against undesired direct operation. Consequences of a malicious action are prevented or mitigated using a validation approach that either blocks the command or ensures a negligible effect on system operation. An example method, suitable for implementation in a monitoring device in an electric power substation, includes receiving a command to open or close a circuit breaker. In response, one or more state parameters for the electric power network that comprises the substation are then predicted, the predicted state parameters reflecting an operating state for the network under the assumption that the received command is executed. The method further comprises comparing the predicted one or more state parameters to corresponding operational limits. Execution of the command is then blocked, in response to determining that one or more of the predicted state parameters violate the corresponding operational limits.

Kondabathini, Anil↗

System and method for detecting false data injection in electrical substations

Unique systems, methods, techniques and apparatuses of a substation phasor data concentrator (ssPDC) is disclosed herein. One exemplary embodiment is a method for operating an electrical substation including a merging unit (MU), a phasor measurement unit (PMU), and a substation phasor data concentrator (ssPDC). The method includes receiving, with the MU and the PMU, input information corresponding to a set of electrical characteristics of the electrical substation; measuring, with the MU, the input information; measuring, with the PMU, the input information; a and estimating, with the ssPDC, electrical characteristics of the electrical substation using the received false measurement and the one of the MU measurement and the PMU measurement, determining in substantially real time the false measurement does not correspond to the set of electrical characteristics using the estimated electric characteristics, and replacing the false measurement with the received the one of the MU measurement and the PMU measurement.

Hong, Junho↗

Securing against malicious control of circuit breakers in electrical substations

An example method for detecting and mitigating attacks on electric power substations comprises detecting a command to open or close a circuit breaker in the electric power substation. A modified extended substation model for the electric power substation is generated, based on the detected command and based on measurements in substation, where the modified extended substation model is a power flow model for the substation and for one or more directly connected neighboring substations. A power flow analysis is performed, using the modified extended substation model, to generate a predicted voltage for each of a plurality of nodes in the substation and in the one or more directly connected neighboring substations. Each predicted voltage is compared to a corresponding allowable voltage range, and execution of the command is blocked in response to determining that one or more of the voltages is outside the corresponding allowable voltage range.

24 POWER TRANSMISSION AND DISTRIBUTION↗