Search NASA⌕ Search

Engineering topics

O’Neil, Galen C.

Publications and source records attributed to O’Neil, Galen C..

Spectroscopic Measurements and Models of Energy Deposition in the Substrate of Quantum Circuits by Natural Ionizing Radiation

Naturally occurring background radiation is a potential source of correlated decoherence events in superconducting qubits that will challenge error-correction schemes. In order to characterize the radiation environment in an unshielded laboratory representative of superconducting qubits’ environments, we performed broadband, spectroscopic measurements of background radiation events inside a millikelvin refrigerator. The spectrometer was designed to mimic the size and composition of a quantum circuit. Specifically, we measured the background radiation spectra in silicon substrates of two thicknesses, 500 and 1500 µm, and one area, 25 mm 2 . The observed spectra span energies from a few kilo-electron-volts up to nearly 10 MeV, are nearly featureless, and decrease in intensity by a factor of 40 000 between 100 keV and 3 MeV for the 500-µm substrate. We integrate the spectra to obtain the average event rates and deposited power levels. These quantities correspond to a rate of 0.023 events per second and a power of 4.9 keV s -1 , when counting events that deposit at least 40 keV for the 500-µm-thick substrate. We find that the cryogenic measurements are in good agreement with predictions based on simple measurements of the terrestrial gamma-ray flux outside the refrigerator, published models of cosmic-ray fluxes, a crude model of the cryostat, and radiation-transport simulations. This model requires no free parameters to predict the background radiation spectra in the silicon substrates. The agreement between measurements and predictions demonstrates that the model we present can be used to assess the relative contributions of terrestrial and cosmic-ray sources to background radiation interactions in silicon substrates of varying thickness. These spectroscopic measurements are performed with a novel combination of superconducting microresonators located on micromachined silicon islands that define the interaction volume with background radiation. The resonators transduce deposited energy to a readily detectable electrical signal. Microresonator readout closely resembles dispersive superconducting qubit readout, so similar devices—with or without micromachined islands—are suitable for integration with superconducting quantum circuits as detectors for background radiation events. For our specific laboratory conditions, we find that gamma-ray emissions from radioisotopes are responsible for the majority of events that deposit E < 1 ⁢Me⁢V. We present results demonstrating that the background radiation spectrum contains relevant contributions from cosmic-ray particles other than muons, particularly a tail of multi-mega-electron-volt events due to protons and neutrons. These observations suggest several paths to reducing the impact of background radiation on quantum circuits, supported by an empirically validated model for generating reliable predictions of radiation interactions with silicon substrates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nanoscale Three-Dimensional Imaging of Integrated Circuits Using a Scanning Electron Microscope and Transition-Edge Sensor Spectrometer

X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but it is difficult to implement due to the competing requirements of X-ray flux and spot size. Due to this constraint, state-of-the-art nanotomography is predominantly performed at large synchrotron facilities. We present a laboratory-scale nanotomography instrument that achieves nanoscale spatial resolution while addressing the limitations of conventional tomography tools. The instrument combines the electron beam of a scanning electron microscope (SEM) with the precise, broadband X-ray detection of a superconducting transition-edge sensor (TES) microcalorimeter. The electron beam generates a highly focused X-ray spot on a metal target held micrometers away from the sample of interest, while the TES spectrometer isolates target photons with a high signal-to-noise ratio. This combination of a focused X-ray spot, energy-resolved X-ray detection, and unique system geometry enables nanoscale, element-specific X-ray imaging in a compact footprint. The proof of concept for this approach to X-ray nanotomography is demonstrated by imaging 160 nm features in three dimensions in six layers of a Cu-SiO 2 integrated circuit, and a path toward finer resolution and enhanced imaging capabilities is discussed.

47 OTHER INSTRUMENTATION↗

Absolute Energy Measurements with Superconducting Transition-Edge Sensors for Muonic X-ray Spectroscopy at 44 keV

Superconducting transition-edge sensor (TES) microcalorimeters have great utility in X-ray applications owing to their high energy resolution, good collecting efficiency and the feasibility of being multiplexed into large arrays. In this work, we develop hard X-ray TESs to measure the absolute energies of muonic-argon (R-Ar) transition lines around 44 keV and 20 keV. TESs with sidecar absorbers of different heat capacities were fabricated and characterized for their energy resolution and calibration uncertainty. Here, we achieved similar to 1 eV absolute energy measurement accuracy at 44 keV, and < 12 eV energy resolution at 17.5 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hyperspectral X-ray Imaging with TES Detectors for Nanoscale Chemical Speciation Mapping

We are developing an imaging capability (“Hyperspectral X-ray Imaging”) for mapping chemical information (molecular formula, phase, oxidation state, hydration) that is based on ultra-high-resolution X-ray emission spectroscopy with large transition-edge sensor microcalorimeter arrays in the scanning electron microscope. By combining microcalorimeter arrays with hundreds of pixels, high-bandwidth microwave frequency-division multiplexing, and fast digital electronics for near real-time data processing, our goal is to enable measurements using laboratory-scale instrumentation rather than synchrotron beamlines. Our application focus here is on mapping the chemical form of uranium compounds on the nanoscale. Furthermore, we will present our approach to developing the Hyperspectral X-ray Imaging capability, progress toward a 128-pixel microwave multiplexed X-ray fluorescence instrument at LANL, and the path to high-throughput nanoscale chemical mapping.

47 OTHER INSTRUMENTATION↗