Sandia's Redesigned Pressure Chamber for the Characterization of Zener DC Voltage Standards
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to O'Brien, Edward.
Explore the source record for details and available documents.
sPHENIX is the first new major detector at RHIC in over twenty years. It is designed for pioneering studies of the Quark Gluon Plasma and Cold QCD phenomena using high-pT jet and heavy flavor probes with a broad kinematic reach and a capability to take large statistics sets of A+A, p+p and p+A data. sPHENIX construction was completed in April 2023. It was commissioned and took first Au+Au data in the RHIC 2023 Run. This paper describes the details of the detector design, challenges of sPHENIX construction, progress on the commissioning and first data from the RHIC 2023 run.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Motivated by the existence of exact many-body quantum scars in the Affleck-Kennedy-Lieb-Tasaki (AKLT) chain, in this work we explore the connection between matrix product state (MPS) wave functions and many-body quantum scarred Hamiltonians. We provide a method to systematically search for and construct parent Hamiltonians with towers of exact eigenstates composed of quasiparticles on top of an MPS wave function. These exact eigenstates have low entanglement in spite of being in the middle of the spectrum, thus violating the strong eigenstate thermalization hypothesis. Using our approach, we recover the AKLT chain starting from the MPS of its ground state, and we derive the most general nearest-neighbor Hamiltonian that shares the AKLT quasiparticle tower of exact eigenstates. We further apply this formalism to other simple MPS wave functions, and derive families of Hamiltonians that exhibit AKLT-like quantum scars. As a consequence, we also construct a scar-preserving deformation that connects the AKLT chain to the integrable spin-1 pure biquadratic model. Finally, we also derive other families of Hamiltonians that exhibit types of exact quantum scars, including a $\textit{U}$(1)-invariant perturbed Potts model.
Abstract not provided.
This specification defines the minimum requirements for the manufacture, performance, and acceptance of a 10 kA Pulsed High Power Calibration System capable of output pulsed current with durations ranging from 1us to 100 us and currents ranging from 0.1 Amperes to 10,000 Amperes.
This document provides instructions for calibrating the Electro-Tech (ETS) electrostatic discharge (ESD) simulator, Model 930D. The calibration shall meet the ± 5% specification for resistance and capacitance as specified in MIL-STD-331C 2009 newer. A series of direct measurements of the Device Under Test (DUT) output at 25 kV using a calibrated LeCroy HDO 6104 oscilloscope (or equivalent 1 MΩ) input impedance storage oscilloscope) are recorded through the 500-pF capacitor, 500-Ω resistor, and a 1-Ω Current Viewing Resistor (CVR). The certified value of the DUT's 25 kV output is calculated using Ohms Law and the certified system resistance and capacitance described in this procedure. Read this document in its entirety before proceeding with the calibration.
The basis of this project was to characterize the various uncertainty contributors of an acoustic chamber. The acoustic chamber will be used to calibrate and characterize infrasound sensors used in the field in the frequency range of 0.001 Hz to 4 Hz. The components characterized include the internal volume of the chamber, the piston area of the speaker creating the dynamic sound wave, the environmental stabilization of the chamber and the chamber's leak rate. Also, the resonant frequency of the chamber was evaluated and found to be far outside the frequency band of interest.