Development Status of Adjustable X-Ray Optics with 0.5 Arcsecond Resolution

We report on the continuing development of adjustable, grazing incidence X-ray optics for 0.5 arcsec telescopes. Adjustable X-ray optics offer the potential for achieving sub-arcsecond imaging resolution while sufficiently thin and light-weight to constitute a mirror assembly with several square meters collecting area. The adjustable mirror concept employs a continuous thin film of piezoelectric material deposited on the back of the paraboloid and hyperboloid mirror segments. Individually addressable electrodes on the piezoelectric layer allow the introduction of deformations in localized "cells" which are used to correct mirror figure errors resulting from fabrication, mounting and aligning the thin mirrors, residual gravity release and temperature changes. We describe recent results of this development. These include improving cell yield to approx. 100 per cent, measurements of hysteresis and stability, comparisons of modeled and measured behavior, simulations of mirror performance, and the development and testing of conical Wolter- I mirror segments. We also present our plans going forward toward the eventual goal of achieving TRL 6 prior to the 2020 Decadal Review.

Reid, P. B.↗

On Calibrations Using the Crab Nebula as a Standard Candle

Inspired by a recent paper (Kirsch et al. 2005) on possible use of the Crab Nebula as a standard candle for calibrating X-ray response func tions, we examine possible consequences of intrinsic departures from a single (absorbed) power law upon such calibrations. We limited our analyses to three more modern X-ray instruments -- the ROSAT/PSPC, th e RXTE/PCA, and the XMM-Newton/EPIC-pn. The results are unexpected an d indicate a need to refine two of the three response functions studi ed. The implications for Chandra will be discussed.

Weisskopf, Martin↗

AS04-AS02-133 Electroformed-Nickel Hard-X-Ray Optic Development at NASA/MSFC

We are developing the nickel electroforming process to fabricate high-quality mirrors for the region. Two applications for these optics are a balloon-borne payload, termed HERO, and a hard-X-ray telescope module for consideration for the Constellation-X mission. In the formation on shells, of 15 arcsec angular resolution, will provide over 200 sq cm of effective collecting area unprecedented sensitivity in the 20-75 keV region. A first flight of a partial payload, feature approximately 1/4 of the total collecting area, is scheduled for the Spring of 2004. In the Co-application, two mirror shells, of diameters 150 and 230 mm, are being fabricated. This is particularly challenging as high angular resolution must be maintained with shells of only 1 mm thickness (driven by the tight weight budget for the mission). Further, the shells must be low (less than 5 A on sub-micron spatial scales) to permit efficient use of planned multilayer coatings which must release cleanly from their forming mandrels without any surface degradation.

Ramsey, Brian↗

Improving the Science Observing Efficiency of the Chandra X-ray Observatory via Chandra Radiation

The Chandra X-ray Observatory (CXO), NASA' latest "Great Observatory", swas launched on July 23, 1999 and reached its final orbit on August 7, 1999. The CXO is in a highly elliptical orbit, approximately 140,000 km x 10,000 km, and has a period of approximately 63.5 hours (approx. 2.65 days). It transits the Earth's Van Allen belts once per orbit during which no science observations can be performed due to the high radiation environment. The Chandra X-ray Observatory Center currently uses the National Space Science Data Center's "near Earth" AP-8/AE-8 radiation belt model to predict the start and end times of passage through the radiation belts. Our earlier analysis demonstrated that our implementation of the AP-8/AE-8 model (a simple dipole model of the Earth's magnetic field) does not always give sufficiently accurate predictions of the start and end times of transit of the Van Allen belts. This led to a change in our operating procedure whereby we "padded" the start and end times of transit by 10 kiloseconds (ks) so that ACIS, the primary science instrument on-board Chandra, would not be exposed to the "fringes" of the Van Allen belts on ingress and egress for any given transit. This additional 20 ks per orbit during which Chandra is unable to perform science observations sums to approximately 3 Ms of "lost" science time per year and therefore reduces the science observing efficiency of the Observatory. To address the need for a higher fidelity radiation model appropriate for the Chandra orbit, the Chandra Radiation Model (CRM) was developed. The CRM is an ion model for the outer magnetosphere and is based on data from the EPIC/ICS instrument on-board the Geotail satellite as well as data from the CEPPAD/IPS instrument on-board the Polar satellite. With the production and implementation of the CRM, we present the results of a study designed to investigate the science observing time that may be recovered by using the CRM as a function of the additional low-energy proton exposure to ACIS.

Virani, Shanil↗