Search NASA⌕ Search

Engineering topics

Obrey, Stephen J.

Publications and source records attributed to Obrey, Stephen J..

Counter gravity heat pipe techniques

A pump assisted heat pipe may combine the low mass flow rate required of latent heat pipe transfer loops with a hermetically sealed pump to overcome the typical heat pipe capillary limit. This may result in a device with substantially higher heat transfer capacity over conventional pumped single-phase loops, heat pipes, loop heat pipes, and capillary pumped loops with very modest power requirements to operate. Further, one or more embodiments overcome the gravitation limitations in the conventional heat pipe configuration, e.g., when the heat addition zone is above the heat rejection zone, the capillary forces are required to transfer the liquid from the heat rejection zone to the heat addition zone against gravity.

Reid, Robert S.↗

Counter gravity heat pipe techniques

A pump assisted heat pipe may combine the low mass flow rate required of latent heat pipe transfer loops with a hermetically sealed pump to overcome the typical heat pipe capillary limit. This may result in a device with substantially higher heat transfer capacity over conventional pumped single-phase loops, heat pipes, loop heat pipes, and capillary pumped loops with very modest power requirements to operate. Further, one or more embodiments overcome the gravitation limitations in the conventional heat pipe configuration, e.g., when the heat addition zone is above the heat rejection zone, the capillary forces are required to transfer the liquid from the heat rejection zone to the heat addition zone against gravity.

Reid, Robert S.↗

Thermal desulfurization of pyrite: An in situ high-T neutron diffraction and DTA–TGA study

To study thermal desulfurization of pyrite (FeS 2 ), we conducted in situ neutron diffraction experiments in the temperature range 298–1073 K. Additionally, on heating, pyrite remained stable up to 773 K, at which it started to decompose into pyrrhotite (Fe 1-x S) and S 2 gas. Rietveld analysis of the neutron data from 298 to 773 K allowed determination of the thermal expansion coefficient of pyrite (space group Pa$\overline{3}$) to be α V = 3.7456 × 10 -5 K -1 , which largely results from the expansion of the Fe–S bond. With further increase in temperature to 1073 K, all the pyrite transformed to pyrrhotite (Fe 1-x S) at 873 K. Unit-cell parameters of Fe 1-x S (space group P6 3 /mmc) increase on heating and decrease on cooling. However, the rates in cell expansion are larger than those in contraction. This hysteresis behavior can be attributed to continuous desulfurization of pyrrhotite (i.e., x in Fe 1-x S decreases) with increasing temperature until the stoichiometric troilite (FeS) was formed at 1073 K. On cooling, troilite underwent a magnetic transition to an orthorhombic structure (space group Pnma) between 473 and 573 K. In addition, using differential thermal analysis (DTA) and thermogravimetric analysis (TGA) implemented with a differential scanning calorimeter, we performed kinetic measurements of pyrite decomposition. Finally, detailed peak profile and Arrhenius (k = A exp(-E a /RT)) analyses yielded an activation energy E a of 302.3 ± 28.6 kJ/mol (based on DTA data) or 302.5 ± 26.4 kJ/mol (based on TGA data) and a ln(A) of 35.3 ± 0.1.

36 MATERIALS SCIENCE↗

Handheld Multi-Gas Meters Assessment Report

Handheld multi-gas meters (MGMs) are equipped with sensors to monitor oxygen (O2) levels and additional sensors to detect the presence of combustible or toxic gases in the environment. This report is limited to operational response-type MGMs that include at least four different sensors. These sensors can vary by type and by the monitored chemical. In real time, the sensors report the concentration of monitored gases in the atmosphere near the MGM. In April 2016 the System Assessment and Validation for Emergency Responders (SAVER) Program conducted an operationally-oriented assessment of MGMs. Five MGMs were assessed by emergency responders. The criteria and scenarios used in this assessment were derived from the results of a focus group of emergency responders with experience in using MGMs. The assessment addressed 16 evaluation criteria in four SAVER categories: Usability, Capability, Maintainability, and Deployability.

47 OTHER INSTRUMENTATION↗

Handheld Multi-Gas Meters Market Survey Report

Handheld multi-gas meters (MGMs) are equipped with sensors to monitor oxygen (O2) levels and additional sensors to detect the presence of combustible or toxic gases in the environment. This report is limited to operational response-type MGMs that include at least four different sensors. These sensors can vary by type and by the chemical monitored. In real time, the sensors report the concentration of monitored gases in the atmosphere near the MGM. To provide emergency responders with information on handheld multi-gas meters, the System Assessment and Validation for Emergency Responders (SAVER) Program conducted a market survey. This market survey report is based on information gathered between November 2015 and February 2016 from vendors, Internet research, industry publications, an emergency responder focus group, and a government issued Request for Information (RFI) that was posted on the Federal Business Opportunities website.

47 OTHER INSTRUMENTATION↗