Techno-economic performance of reservoir thermal energy storage for data center cooling system
Not Available
Engineering topics
Publications and source records attributed to Oh, Hyunjun.
Not Available
Repurposing abandoned oil and gas infrastructure for geothermal energy production has great potential to reduce greenhouse gas (GHG) emissions. This study quantified the life cycle global warming potential of geothermal energy production using four inactive oil and gas wells repurposed for district heating in Tuttle, Oklahoma. A cradle-to-grave prospective life cycle assessment was performed to compare GHG emissions between the geothermal district heating system and conventional natural gas-fired heating system from 2020 to 2050. For initial implementation of the geothermal system, we investigated two approaches: 1) repurposing abandoned infrastructure from a nearby oil and gas well site, and 2) production and injection well drillings including new construction of a central heat exchange station. Environmental impacts from the geothermal system were estimated for five scenarios where a natural gas peaking boiler is incorporated to supply peak heat demand. The prospective results indicated that cumulative reduction in GHG emissions from transitioning to the geothermal district heating system increase over time as a function of future renewable resource penetration and technological advancements within electricity, fuel, and steel production. Over 30 years, the global warming potential associated with the district heating demand will have been reduced by up to 24 % with the repurposed system. These results imply that repurposing existing oil and gas infrastructure for geothermal energy systems of district heating will bring future climate benefits.
This study builds on the existing techno economic and environmental life cycle assessments performed for a geothermal district heating and cooling system implementation in Tuttle Oklahoma with four existing oil and gas wells. Its resilience in meeting the peak annual heating and cooling loads of the district assuming a temporary disconnection from the electrical grid is assessed both qualitatively and quantitatively. Attributes of resilience and qualitative criteria established by Kolker et al. (2022) for geothermal district heating systems are applied to the proposed case to highlight its vulnerabilities. Results indicate that increasing the redundancy and diversity in the physical configuration of the distributional piping can considerably increase the system's resilience. A quantitative assessment executed via the REopt tool predicts that the ancillary electricity required to power the geothermal system's heating and cooling can be met by an onsite emergency diesel generator during times of grid outages for over 28 days.
Flexibility is the capability of the power grid to maintain a balance between electricity generation and variable demand. This study presents preliminary results evaluating the impact of geothermal district heating systems on the flexibility of microgrid in Tuttle, Oklahoma. Heating demand profiles were modeled using EnergyPlus for the district that includes two schools and 250 single-family houses. Then, geothermal energy production was modeled using GEOPHIRES to estimate how much heating demand in the district can be supplied by five different geothermal system scenarios. The results indicated that geothermal energy production varied depending on the resource temperature at different depths, system configurations, and flow rates. For the grid flexibility analysis, electricity consumptions in the five geothermal systems were estimated for pump operations to circulate water from the wells to radiators, while electricity consumption by air-source heat pump in the base case was estimated to supply the same heating load. Electricity consumption in the geothermal systems was significantly lower than those in base cases. The electricity saved by the geothermal system was then incorporated into the microgrid electrical load profiles where variable renewable electricity generation is significantly high. The results visually showed that geothermal district heating system can improve grid flexibility as a baseload during the winter season. The results also highlighted potential opportunities to save energy costs that will be further analyzed in future study.
Geothermal district energy systems (DES) with ambient-temperature loops, also known as thermal energy networks, are one option for decarbonizing space heating and cooling loads. Geothermal fifth-generation DES include an "ambient" temperature thermal loop that connects heat pumps at each building with thermal balancing sources such as geothermal borehole fields. Heating and cooling are provided via a water-source heat pump at each end-user. This project seeks to analyze the nationwide potential for ambient-temperature loop districts by creating a new module within the Distributed Geothermal Market Demand Model (dGeo). dGeo is an agent-based modeling tool for distributed geothermal resources; it can investigate potential on a nationwide or statewide scale using geospatial data for all 50 states and thermal demands for existing buildings. This process allows for high-level estimates of technical and economic potential for ambient-temperature loop districts across the United States. A lookup table was created using GHEDesigner to size borehole fields for different thermal loads and ground conditions experienced across the country. A cost and financing structure, along with incentives, were applied. Cost estimates include costs for the distribution network, borehole field installation and operation, and circulation pump operation, while savings are calculated based on energy bills for building owners (agents). This newly developed module can be used for assessing which areas of the country have the highest potential for agent benefits from ambient-temperature loop installation and assess the impact of future cost and price scenarios. Initial results for statewide analysis (for Vermont) and nationwide (for United States) are provided. Future work includes expanding the module to consider mixed residential and commercial districts as well as evaluating multiple cost scenarios.
Fuel based end-uses for residential, commercial, and industrial consumers require a technology change to achieve economy-wide decarbonization. Space heating accounts for 42% of residential and 32% of commercial energy demand, much of which is currently met through carbon emitting fuels. Industrial energy use is heavily fuel based with electricity currently representing 13% of energy demand. Geothermal heat pumps (GHPs) and geothermal direct use can eliminate the need for CO2 emitting and simultaneously allow for more efficient electrification of end uses. Past work has assessed the impact on total energy costs and generation investments but did not identify specific grid services benefited. Energy usage in residential and commercial structures was assessed by leveraging data from ComStock and ResStock models. These models utilize housing attributes, occupancy patterns, weather data, and sophisticated energy simulations to generate hourly load profiles for individual buildings identified by unique IDs associated with their locations. Industrial sector energy use was evaluated using information from the Manufacturing Energy Consumption Survey (MECS) as well as plant utilization data from the US Census to estimate hourly plant operations. The change in end-use demand for electricity, natural gas, and other fuels was calculated for different technologies that could meet this need. Using the ReEDS capacity expansion model, we produce regional price profiles that capture the grid benefit associated with the amount and timing of energy shifts in the power system from the adoption of geothermal systems relative to other technologies that could meet space heating, space cooling, and process heat requirements. We find that geothermal systems for meeting end-use demand add value to the energy system. In buildings where geothermal systems increase grid costs, these values are offset by reduced fuel costs and benefits to externalities, including emissions and health impacts.
Geothermal district energy systems (DES) with ambient-temperature loops, also known as thermal energy networks, are one option for decarbonizing space heating and cooling loads. Geothermal fifth-generation DES include an "ambient" temperature thermal loop that connects heat pumps at each building with thermal balancing sources such as geothermal borehole fields. Heating and cooling are provided via a water-source heat pump at each end-user. This project seeks to analyze the nationwide potential for ambient-temperature loop districts by creating a new module within the Distributed Geothermal Market Demand Model (dGeo). dGeo is an agent-based modeling tool for distributed geothermal resources; it can investigate potential on a nationwide or statewide scale using geospatial data for all 50 states and thermal demands for existing buildings. This process allows for high-level estimates of technical and economic potential for ambient-temperature loop districts across the United States. Using GHEDesigner, a lookup table was created to size borehole fields for different thermal loads and ground conditions experienced across the country. A cost and financing structure, along with incentives, were applied. Cost estimates include costs for the distribution network, borehole field installation and operation, and circulation pump operation, while savings are calculated based on agent energy bills. This newly developed module can be used for assessing which areas of the country have the highest potential for agent benefits from ambient-temperature loop installation and assess the impact of different costing and pricing future scenarios. While the code is still under development and nationwide simulations are ongoing, initial results for two states are provided. Future work includes expanding the module to consider mixed residential and commercial districts and considering multiple costing scenarios.
Flexibility is the capability of the power grid to maintain a balance between electricity generation and variable demand. This study presents preliminary results evaluating the impact of geothermal district heating systems on the flexibility of a conceptual microgrid in Tuttle, Oklahoma. Heating demand profiles were modeled using EnergyPlus for the district that includes two schools and 250 single-family houses. Then, geothermal energy production was modeled using GEOPHIRES to estimate how much heating demand in the district can be supplied by five different geothermal system scenarios. The results indicated that geothermal energy production varied depending on the resource temperature at different depths, system configurations, and flow rates. For the grid flexibility analysis, electricity consumptions in the five geothermal systems were estimated for pump operations to circulate water from the wells to radiators, while electricity consumption by air-source heat pump in the base case was estimated to supply the same heating load. Electricity consumption in the geothermal systems was significantly lower than those in base cases. The electricity saved by the geothermal system was then incorporated into the microgrid electrical load profiles where variable renewable electricity generation is significantly high. The results visually showed that geothermal district heating system can improve grid flexibility as a baseload during the winter season. The results also highlighted potential opportunities to save energy costs that will be further analyzed in future study.
This study builds on the existing techno-economic and environmental life cycle assessments performed for a geothermal district heating and cooling system implementation in Tuttle Oklahoma with four existing oil and gas wells. Its resilience in meeting the peak annual heating and cooling loads of the district assuming a temporary disconnection from the electrical grid is assessed both qualitatively and quantitatively. Attributes of resilience and qualitative criteria established by Kolker et al. (2022) for geothermal district heating systems are applied to the proposed case to highlight its vulnerabilities. Results indicate that increasing the redundancy and diversity in the physical configuration of the distributional piping can considerably increase the system’s resilience. A quantitative assessment executed via the REopt tool predicts that the ancillary electricity required to power the geothermal system’s heating and cooling can be met by an onsite emergency diesel generator during times of grid outages for over 28 days.
This presentation informs U.S. Department of Agriculture (USDA) staff on geothermal technologies which can provide clean energy for agricultural producers and rural small business owners.
Thermal demand for heating and cooling has been predominantly supplied by fossil fuel combustion in the United States, although low-carbon alternatives are extensively available including geothermal, solar thermal, and waste heat. Here, this study analyzed end-use energy consumption, fuel expenditure, and data center commissioned power data to geospatially characterize the U.S. low-temperature heating and cooling demand at the county level in residential, commercial, manufacturing, agricultural, and data center sectors and understand potential opportunities for geothermal applications. In the analysis, the regional-scale energy consumption data was incorporated with system efficiencies to address actual demand and was then disaggregated with weighting factors to the county level. The results indicated that total low-temperature heating and cooling demand is 16.7 EJ, combining heating demand of 10.8 EJ and cooling demand of 5.9 EJ. Overall, 59.9 % (10 EJ) of the low-temperature heating and cooling demand occurred in the residential sector. The heating and cooling demand visualized in maps represented that the geospatial distribution of heating and cooling demand in the residential and commercial sectors is governed by the number of housing units and climate zone designations, while heating and cooling demand in the manufacturing, agricultural, and data center sectors is dependent on the number and location of facilities. The results also demonstrated that geothermal heat pumps are broadly used in the residential and commercial sectors for heating and cooling in the U.S. Midwest, South, and Northeast regions but are limited in the West, implying great decarbonization potential in the future.
Oil and gas wells have been drilled in the United States and often encounter hot co-produced water possibly suitable for geothermal direct-use applications. Here this study evaluated geothermal resources, heating and cooling demand, and techno-economic potential of four oil and gas wells repurposed for geothermal energy production to serve two public schools and 250 nearby houses in Tuttle, Oklahoma, USA. Subsurface geology in the study area primarily consists of Permian to Mississippian sandstone and limestone formations approximately from 2 km to 3.5 km depth. With a geothermal gradient of 25.3 °C/km, the temperature of geothermal energy production was estimated as 68.2 °C at 2.1 km. The potential of calcite scaling within boreholes and pipes was minimal. Using the characterized reservoir properties, techno-economic analyses were conducted for evaluating levelized costs of geothermal energy production for direct-use heating and cooling and district heating systems with five different production scenarios. Heating and cooling demand in two schools and 250 houses and additional 0.3 MW and 0.6 MW base heating loads for potential geothermal direct-use applications in the study area were also incorporated in the modeling. Results indicated that the levelized cost of heating of geothermal district heating systems utilizing existing wells were significantly lower than those of conventional geothermal energy systems that include well drillings. The geothermal energy production with doublet and quartet configurations was generally sufficient to supply total annual heating demand in the district, while a peaking boiler was used to supply peak loads. Doublet configurations showed higher production temperature with a lower thermal drawdown than the quartet configurations. The doublet system at 2.1 km production depth with 9.3 kg/s flow rate represented the optimal levelized cost of $71/MWh and 91.2% utilization factor. These results imply that the Tuttle geothermal district heating system is techno-economically feasible and comparable to geothermal district heating systems in the United States and the regional natural gas rate for residentials by recycling inactive oil and gas wells with no drillings.
Geothermal deep direct use (DDU) has potential across a wide swath of the United States but is underutilized due to challenging project economics associated with developing a deep geothermal resource for a large-scale and variable heat demand. The National Renewable Energy Laboratory (NREL) and University of Oklahoma evaluated the feasibility of a geothermal district heating (GDH) and cooling system in two schools and 250 houses by utilizing existing oil and gas (O&G) wells in Tuttle, Oklahoma. Heating and cooling demand in the two schools and a typical single-family house were modeled using EnergyPlus building energy simulation software. The modeling results indicated that annual heating demand in two schools and 250 houses is approximately 2.61 GWhth, and cooling demand in the two schools is approximately 2.65 GWhth. In this scope, the techno-economic analysis (TEA) was conducted using the GEOPHIRES tool combined with the TOUGH2 reservoir simulator. The reservoir performance, including geothermal heat production capacity, was modeled by the reservoir simulator TOUGH2. Then, levelized cost of heat (LCOH) was calculated using GEOPHIRES version 3.0, which includes new features such as hourly heat load optimization and peak performance evaluation. Geothermal reservoir temperature was estimated as 90.5 degrees C at a total depth of 3.3 km by the regional average temperature gradient of 22.8 degrees C/km and validated by cation geothermometer calculations. Four production scenarios with two different well configurations and two different heat load profiles have been developed for well flow rates ranging between 3.1 kg/s and 9.3 kg/s. The LCOH of the district heating and cooling system was calculated between $95 and $210/MWh ($28/MMBtu to $62/MMBtu) for four different production scenarios. Typical natural gas prices for residential customers in Oklahoma have ranged from 9 to 19 $/MMBtu over the past decade, which indicates a challenge for deployment of such a GDH system.
Oil and gas (O&G) wells often encounter co-produced hot water, possibly suitable for geothermal direct-use applications. The City of Tuttle is located on the eastern part of the Anadarko sedimentary basin in Oklahoma with high heat-in-place potential and recovery capability at depth. This study aims at demonstrating the potential of geothermal energy production for direct-use applications in two public schools and 250 nearby houses in Tuttle via repurposing existing O&G wells. In this scope, geochemistry, geology, and borehole log data were collected and incorporated into a 3D conceptual subsurface model. A digital elevation model (DEM) was used to represent the study area topography with four O&G wells. In addition, hydrogeochemical characteristics of the geothermal fluid and scaling potential were analyzed using ternary diagrams and chemical ratios to develop mixing models. The subsurface geology model indicated that the study area primarily consists of Permian to Mississippian Sandstone and Limestone formations, implying a porosity ranging between 12% and 22%, and a permeability up to 3.90E-14 m2 in certain reservoir levels. The reservoir temperature is expected to be ranging between 80 degrees C to 95 degrees C around 3 km depth with an average temperature gradient of 22.8 degrees C/km. Chemical geothermometers also estimated the reservoir temperature as 90 degrees C. Findings of the chemical model demonstrated that the geothermal fluid is Sodium-Potassium-Chloride-Sulfate type and possibly mixed with shallow groundwater resulting in higher Ca and Mg concentrations and lower Na/K ratio implying lower calcite scaling. These results comprehensively characterize the potential of geothermal resources in the study area and imply that geothermal energy production by repurposing existing O&G wells is suitable for low-temperature direct-use applications.
This study aims to evaluate the feasibility of addressing the cooling needs for information technology (IT) equipment in data centers by using reservoir thermal energy storage (RTES) to provide reliable and sustainable low-temperature fluid. This project focuses on the technical viability of operating such a system in Houston, Texas, which is a representative location for crypto mining data centers. An analysis has been performed to investigate the technical feasibility with climate data for Houston. Results show that data centers on the scale of 30 MW, and operating at a temperature of 27 degrees C, can be reliably cooled by a combined RTES and dry coolers setup. A techno-economic analysis will be performed and energy/water saving benefits will be quantified in the future. In addition, the study will be extended to other representative data center locations with different climates and geographical locations.
District energy systems supplied by geothermal heat pumps (GHPs) have been deployed across the United States for both heating and cooling end uses. To better understand their performance and potential, the geothermal research team at the National Renewable Energy Laboratory analyzed cost and performance of five existing GHP-based district energy systems in the United States. The five systems selected are Ball State University in Indiana, Colorado Mesa University in Colorado, Miami University in Ohio, West Union in Iowa, and Whisper Valley in Texas. The necessary information, including district size, operation period, GHP performance, and costs, was collected through literature review and interviews. The survey results indicated the five systems studied consist of geothermal borehole field(s) and ground loop(s) connected to central loop. While the GHPs were in central plants at Ball State University and Miami University, the central loops at Colorado Mesa University, West Wood, and Whisper Valley were connected through service lines to individual heat pumps in each building. Our analysis indicates the systems have been operating reliably and cost-effectively and contributed to a reduction in carbon emissions.
This dataset includes U.S. low-temperature heating and cooling demand at the county level in major end-use sectors: residential, commercial, manufacturing, agricultural, and data centers. Census division-level end-use energy consumption, expenditure, and commissioned power database were dis-aggregated to the county level. The county-level database was incorporated with climate zone, numbers of housing units and farms, farm size, and coefficient of performance (COP) for heating and cooling demand analysis. This dataset also includes a paper containing a full explanation of the methodologies used and maps. Residential data were updated from the latest Residential Energy Consumption Survey (RECS) dataset (2015) using 2020 census data. Commercial data were baselined off the latest Commercial Building Energy Consumption Survey (CBECS) dataset (2012). Manufacturing data were baselined off the latest Manufacturing Energy Consumption Survey (MECS) dataset (2021).